Technology | Peripheral Artery Disease (PAD) | April 15, 2019

FDA Clears Intact Vascular’s Tack Endovascular System

First-of-its-kind treatment for post-angioplasty above-the-knee dissections 

Intact Vascular Inc. received U.S. Food and Drug Administration (FDA) market clearance for the Tack Endovascular System. This is a purpose-built dissection repair device implanted post-angioplasty in patients with peripheral arterial disease (PAD).

April 15, 2019 – Intact Vascular Inc. received U.S. Food and Drug Administration (FDA) market clearance for the Tack Endovascular System. This is a purpose-built dissection repair device implanted post-angioplasty in patients with peripheral arterial disease (PAD).

Regulatory approval was based on data from Intact Vascular’s Tack Optimized Balloon Angioplasty II (TOBA II) pivotal trial, which demonstrated the safety and effectiveness of the Tack implant to resolve dissections following angioplasty. Data from the pivotal trial were presented in a late-breaking scientific session at the 2018 VIVA conference.

“I look forward to having the Tack implant available for my patients,” said William Gray, M.D., system chief, Division of Cardiovascular Disease at Main Line Health, president, Lankenau Heart Institute and principal investigator for the TOBA II trial. “Post-angioplasty dissections can significantly impact patient outcomes. Having a minimal metal solution that specifically addresses dissections and improves angioplasty results while preserving future treatment options is extremely exciting.”

The inflation of an angioplasty balloon and resulting mechanical stress inherently injures vessels and creates dissections. These dissections are prevalent, underdiagnosed and underestimated.[1] If left untreated, dissections can compromise clinical outcomes, resulting in acute thrombosis and arterial occlusions, leading to lower long-term patency rates and repeat procedures.

The TOBA II pivotal trial, notably the first peripheral vascular study to enroll patients with 100 percent dissected vessels, met all primary endpoints with 92 percent of dissections completely resolved following treatment. In this challenging patient population, the Tack implant demonstrated 79.3 percent K-M vessel patency and 86.5 percent K-M freedom from clinically driven reintervention at 12 months, with only a 0.5 percent bailout stent rate and zero implant fractures.[2]

Intact Vascular recently announced its European launch and first commercial cases in several centers across Germany. With FDA approval granted, the company plans a limited initial release in the US that will progress toward broader market commercialization.

For more information: www.intactvascular.com

 

Related Tack Device Content

New Peripheral Stent Technology

Intact Vascular Announces $20 Million Series C Financing

 

References:

1. Bosiers M, Scheinert D, Hendricks JMH et al. Results from the Tack Optimized Balloon Angioplasty (TOBA) study demonstrate the benefits of minimal metal implants for dissection repair after angioplasty. J Vasc Surg 2016;64:109-16.

2. Intact Vascular Announces Positive One-Year Data from the TOBA II Clinical Trial. AP News, Business Wire. Nov. 6, 2018. www.apnews.com/49f66baac3834c8a80bcf8351fccd855.

Related Content

New Alliance Announced Between Transcatheter Cardiovascular Therapeutics and VEITHsymposium
News | Cath Lab | June 20, 2019
VEITHsymposium and the Cardiovascular Research Foundation (CRF) announced an alliance between Transcatheter...
Novel Index Accurately Predicts PCI Success Post-Procedure Compared to Established Measurement Metrics
News | Cath Lab | June 19, 2019
Results from a comprehensive analysis demonstrate the effectiveness of measuring a non-hyperemic pressure ratio (NHPR...
Philips Healthcare, Volcano IVUS showing an implanted stent. IVUS might offer an alternative to contrast angiography in patients with acute kidney disease (AKD).
News | Cath Lab | June 14, 2019
June 14, 2019 – A late-breaking study examined the effects of intravascular ultrasound (IVUS) guided drug-eluting ste
Videos | Cath Lab | May 20, 2019
This is a walk through of the primary structural heart hybrid cath lab at...
Mobility May Predict Elderly Heart Attack Survivors' Repeat Hospital Stays
News | Cath Lab | April 23, 2019
Determining which elderly heart attack patients take longer to stand from a seated position and walk across a room may...
FDA Releases New Guidance on Medical Devices Containing Nitinol
News | Cath Lab | April 18, 2019
April 18, 2019 — The U.S.
Angiography shows a stenotic lesion in the mid right coronary artery, undilatable by standard high-pressure balloon angioplasty (inset, arrowheads). (B) Optical coherence tomography (OCT) cross-sectional (top) and longitudinal (bottom) images acquired before IVL and coregistered to the OCT lens (arrow in A) demonstrate severe near-circumferential calcification in the area of the stenosis. (C) Angiography demonstrates improvement in the area of stenosis after IVL lithoplasty.

Figure 2: Angiography demonstrates a stenotic lesion in the mid right coronary artery, undilatable by standard high-pressure balloon angioplasty (inset, arrowheads). (B) Optical coherence tomography (OCT) cross-sectional (top) and longitudinal (bottom) images acquired before IVL and coregistered to the OCT lens (arrow in A) demonstrate severe near-circumferential calcification (double-headed arrow) in the area of the stenosis. (C) Angiography demonstrates improvement in the area of stenosis after IVL (inset; note the cavitation bubbles generated by IVL [black arrows]). (D) OCT cross-sectional (top) and longitudinal (bottom) images acquired post-IVL and coregistered to the OCT lens (white arrow in C) demonstrate multiple calcium fractures and large acute luminal gain. (E) Angiography demonstrates complete stent expansion with the semicompliant stent balloon (inset) without the need for high-pressure noncompliant balloon inflation. (F) OCT cross-sectional (top) and longitudinal (bottom) images acquired post-stenting and coregistered to the OCT lens (arrow in E) demonstrate further fracture displacement (arrow), with additional increase in the acute area gain (5.17 mm2), resulting in full stent expansion and minimal malapposition.

Feature | Cath Lab | April 15, 2019 | Dean Kereiakes, M.D., FACC, FSCAI, and Jonathan Hill, M.D., DISRUPT CAD III Co-Principal Investigators
Over the last 40 years, despite multiple advancements in percutaneous coronary interventions, calcified lesions remai
BIOTRONIK’s PK Papyrus covered coronary stent. The stent ius used in emergency coronary artery dissections to repair the vessel wall.
Technology | Cath Lab | April 15, 2019
April 15, 2019 — Biotronik began its U.S.