News | July 01, 2013

Medtronic’s In.Pact Falcon Drug-Eluting Balloon Yields Positive Outcomes in Small Coronary Arteries

Presented at EuroPCR, one-year data from BELLO study show durability of clinical results following treatment of de novo lesions with novel angioplasty device

July 1, 2013 — One-year data from an Italian multicenter randomized controlled trial of the In.Pact Falcon drug-eluting balloon from Medtronic demonstrate positive and durable clinical results with the novel angioplasty device in the treatment of stenotic de novo lesions in small coronary arteries, according to a presentation made at EuroPCR.

The new data come from the BELLO (Balloon Elution and Late Loss Optimization) clinical study, which enrolled 182 patients across 15 hospitals in Italy to evaluate the safety and effectiveness of two medical devices: Medtronic’s In.Pact Falcon drug-eluting balloon (DEB) and the Taxus drug-eluting stent (DES) from Boston Scientific.

Nearly two-thirds (64.9 percent) of the vessels treated in the BELLO study with the drug-eluting balloon were smaller than 2.25 mm in diameter, for which no drug-eluting stent is currently available.

The previously presented six-month angiographic outcomes of the BELLO study favored patients treated with the drug-eluting balloon. The study met its primary endpoint, late lumen loss at six months, with statistical significance showing superiority of the drug-eluting balloon over the drug-eluting stent (0.08 vs. 0.29 mm, p=0.001).

Building on these data, the latest results from the BELLO study continue to demonstrate favorable outcomes for the In.Pact Falcon drug-eluting balloon. At one year, the clinical outcomes of major adverse cardiac events (MACE), myocardial infarction (MI) and target lesion revascularization (TLR) were statistically similar for both devices:

  • MACE – DEB, 10%; DES, 18.5% (p=0.31)
  • MI – DEB, 1.1%; DES, 5.5% (p=0.10)
  • TLR – DEB, 4.4%, DES, 9.8% (p=0.25)

“The BELLO study shows that treating de novo coronary lesions with the In.Pact Falcon drug-eluting balloon is a viable option, with strong clinical outcomes to one year,” said the presenter of the new data, Dr. Azeem Latib of San Raffaele Hospital and EMO-GVM Centro Cuore Columbus in Milan. “The one-year results suggest that this novel angioplasty device should not necessarily be limited to only treating in-stent restenosis in coronary arteries. They also suggest that lesions in relatively small coronary arteries are possibly a strong application for this particular device.”

The Medtronic In.Pact Falcon drug-eluting balloon received CE (Conformité Européenne) mark in 2009 and is available in many countries around the world. It is not commercially available in the United States.

www.medtronic.com

 

Related Content

DISRUPT BTK Study Shows Positive Results With Lithoplasty in Calcified Lesions Below the Knee
News | Peripheral Artery Disease (PAD)| September 20, 2017
Shockwave Medical reported positive results from the DISRUPT BTK Study, which were presented at the annual...
Corindus Announces First Patient Enrolled in PRECISION GRX Registry
News | Robotic Systems| September 18, 2017
September 18, 2017 — Corindus Vascular Robotics Inc.
Two-Year ILLUMENATE Trial Data Demonstrate Efficacy of Stellarex Drug-Coated Balloon
News | Drug-Eluting Balloons| September 18, 2017
Philips announced the two-year results from the ILLUMENATE European randomized clinical trial (EU RCT) demonstrating...
Sentinel Cerebral Protection System Significantly Reduces Stroke and Mortality in TAVR
News | Embolic Protection Devices| September 18, 2017
September 18, 2017 – Claret Medical announced publication of a new study in the...
Fysicon Receives FDA Approval for QMAPP Hemodynamic Monitoring System
Technology | Hemodynamic Monitoring Systems| September 18, 2017
Fysicon announced that it has been granted 510(k) clearance by the U.S. Food and Drug Administration (FDA) for its...
Marijuana Associated With Three-Fold Risk of Death From Hypertension
News | Hypertension| September 14, 2017
Marijuana use is associated with a three-fold risk of death from hypertension, according to research published recently...
Peter Schneider, M.D. presents late breaking clinical trial results at VIVA 17 in Las Vegas. Panelists (l to r) Krishna Rocha-Singh, M.D., Sean Lyden, M.D., John Kaufman, M.D., Donna Buckley, M.D.

Peter Schneider, M.D. presents late breaking clinical trial results at VIVA 17 in Las Vegas. Panelists (l to r) Krishna Rocha-Singh, M.D., Sean Lyden, M.D., John Kaufman, M.D., Donna Buckley, M.D.

Feature | Cath Lab| September 14, 2017
September 14, 2017 — Here are quick summaries for all the key late-breaking vascular and endovascular clinical trials
Mississippi Surgical and Vascular Center Uses Toshiba Ultimax-i FPD to Save Patients' Limbs
News | Angiography| September 14, 2017
The southern U.S. sees some of the highest numbers of chronic medical conditions, such as peripheral artery disease...
Sponsored Content | Videos | Structural Heart Occluders| September 13, 2017
Ziyad Hijazi, M.D., MPH, MSCAI, FACC, director of the cardiac program and chair of the Department of Pediatrics at Si
Philips Showcases Integrated Vascular Solutions at VIVA 2017
News | Peripheral Artery Disease (PAD)| September 13, 2017
Philips announced its presence at the Vascular Interventional Advances (VIVA 17) Annual Conference in Las Vegas from...
Overlay Init