Feature | November 23, 2011| Dave Fornell

Advances in Vascular Imaging Systems

This article appeared as the introduction to a chart on vascular imaging systems in the November/December 2011 issue.

Philips Healthcare Allura Xper FD20

Over the last 10 years, hospitals have phased out analog image intensifiers for flat-panel, digital detector angiography systems in their cath labs. As hospitals look to purchase current-generation digital angiography systems, buyers should be aware of several new technologies.

Better Navigation Aids
A key feature of newer systems is the use of rotational angiography, in which the C-arm makes a quick rotation around the patient to create a computed tomography (CT)-like 3-D image. A CT image has a resolution of about 1 Hounsfield unit (HU), while the resolution of a CT-like angiography image is about 10 HU.1  These dataset images can be used to segment out vessels or anatomy of interest as a navigation aid. Most systems also allow overlays on the images on the fluoroscopic view to help define structures and vessels, aid navigation and reduce the amount of contrast. These roadmap images can be fused with the orientation of the C-arm for better catheter navigation.

Today’s angiography systems offer software to take CT or magnetic resonance imaging (MRI) datasets that can be registered with the fluoro view. These hybrid images can then be rotated with the orientation of the C-arm to help with navigation. The opacity of the overlay image can be adjusted for optimal viewing of the live angio.

Some systems also offer software to enhance percutaneous devices. These show if stents are fully apposed to the vessel wall or better visualize the results of bifurcation stenting. An example of this is GE Healthcare’s StentVis, which uses elastic registration that takes radiopaque markers and guide wires into account to create more contrast and to better visualize stents.

Dose-Lowering Technologies
Manufacturers have developed a variety of new features to help lower and monitor ionizing X-ray radiation dose. Features include image enhancement software to enable the use of lower-dose imaging and easy tableside frame rate adjustment. An example of this is Toshiba’s Infinix-i, where tableside controls can adjust the pulse fluoro frame rate settings. The system also offers virtual collimation, where an electronic outline guides collimator blade placement, avoiding the use of fluoroscopy for positioning.

GE’s Dynamic Range Management (DRM) software enhances structures of interest on hard-to-read angiographic images to transform background thickness, vessel contrast, background contrast and background brightness, and reduce problems with image blackout and burnout.

Siemens Healthcare’s Artis zee system offers several Combined Applications to Reduce Exposure (CARE) modules to assist with dose reduction without compromising image quality. CARE Vison uses low pulsing frequencies to meet individual dose-saving targets below 10 p/s, down to 0.5 p/s. CARE Filter uses additional Cu-filters to reduce skin dose by more than 70 percent in some patients based on patient weight. CARE Profile adjusts the collimators and wedge filters without using fluoroscopy.

Some vendors offer dose monitoring to warn clinicians when they enter the radiation field (Philips’ DoseAware) or track radiation usage (GE’s Innova Dose Reports).  

Hybrid OR Needs
Minimally invasive and transcatheter procedures continue to reduce the need for open surgery, which has placed greater demands for vascular imaging systems in the surgical suite. Also, many hospitals are developing hybrid operating rooms (ORs) so both surgical and interventional procedures can be performed in one location. If creating a hybrid OR, key angiography system considerations include installing displays that can easily be sterilized, the ability of the C-arm to be moved out of the way for better patient access and the movement of the patient table.

Surgical tables need to be raised and lowered for better patient accessibility. Some tables also can tilt to raise different parts of the body to help with surgical access.

Angiography systems come in both floor- and ceiling-mounted configurations, which may be a deciding factor in some installations. ORs require much larger square footage than cath labs to accommodate additional staff, anesthesiology, surgical equipment and space to transfer patients. Some hospitals have found ceiling-mounted systems are useful to swing the C-arm completely out of the way and to eliminate obstacles on the floor, especially in smaller hybrid suites.   

Interface Considerations
Angiography systems are no longer used as a sole imaging or diagnostic modality in the cath lab, so interfaces with other systems help improve workflow. Ultrasound is playing an increasing role, with intravascular ultrasound (IVUS) to guide vascular interventions and intracardiac echo (ICE) and transesophageal echo (TEE) to help guide structural heart procedures. Conventional ultrasound systems are also seeing increased use to reduce X-ray radiation and guide procedures, especially in peripheral vascular interventions. Optical coherence tomography (OCT) and fractional flow reserve (FFR) also are becoming key tools in guiding vascular interventions.

Electrophysiology (EP) frequently shares the cath lab, so integration with EP mapping and navigation systems also might be an important consideration.

References:
1. Jacques Kpodonu. “Manual of Thoracic Endoarortic Surgery.” Springer, 2010.

Related Content

HeartFlow, FFR-CT, ruptured coronary plaques, EMERALD study, EuroPCR 2016
News | CT Angiography (CTA)| May 23, 2016
First-in-human data presented at EuroPCR 2016 demonstrate that hemodynamic data from HeartFlow Inc. may help predict...
Technology | Cardiac Imaging| May 18, 2016
May 18, 2016 — The Intersocietal Accreditation Commission (IAC) recently announced its launch of the IAC QI Self-Asse
Osprey Avert
News | Cath Lab| May 13, 2016
May 13, 2016 — In the largest study of its kind, a new device has been found to significantly reduce the volume of ra
Sponsored Content | Videos | HIMSS| May 13, 2016
ITN/DAIC Editor Dave Fornell takes a tour of some of the most innovative new trends and health information t
Radiation dose management, radiation dose monitoring, X-ray dose

Analytics from Sectra’s radiation dose monitoring software showing procedures where dose levels were higher than normal for various X-ray modalities. 

Feature | Radiation Dose Management| May 12, 2016 | Lori Webb, R.T. (R) and Tom Watson, RCVT
Healthcare organizations, clinicians and medical equipment manufacturers have long focused on the management and redu
radiation dose in the cath lab
News | Radiation Dose Management| May 02, 2016
May 2, 2016 — Starting at the Society for Cardiovascular Angiography and Interventions (SCAI) 2016 annual meeting May
FFR-CT, heartflow
Feature | CT Angiography (CTA)| April 15, 2016 | Jeff Zagoudis
Fractional flow reserve-computed tomography (FFR-CT) is still in the early stages of clinical implementation in the U
TAVR runoff image

A 3-D CT reconstruction of a TAVR run-off image to assess the femoral access route using Toshiba's Aquillion One and Vital Images advanced visualization technologies. 

Feature | Heart Valve Technology| April 15, 2016
April 15, 2016 — Accurate and precise anatomical information is crucial to successful transcatheter aortic valve repl
Toshiba

Kidney ultrasound perfusion exam, courtesy of Toshiba.

Feature | Angiography| April 15, 2016
April 15, 2016 — Patients treated with CMX-2043 — an investigational drug that has previously shown some ability to p
Sponsored Content | Videos | CT Angiography (CTA)| April 12, 2016
A discussion on the adoption rate of FFR-CT with Dr. Campbell Rogers, chief medical officer of HeartFlow.
Overlay Init