Feature | September 05, 2013

Cardiac Resychronization Therapy Fails for Certain Heart Failure Patients

The EchoCRT trial was ended early to prevent harm to patients

September 5, 2013 — Researchers announced this week that an attempt to expand cardiac resynchronization therapy (CRT) to include more patients with heart failure has failed and an international clinical trial ended early to prevent potential harm to patients. 
 
The Echocardiography Guided Cardiac Resynchronization Therapy (EchoCRT) is the largest international, multicentre, prospective, randomized, double-blind, clinical trial of its kind. Results of the trial are available online by the New England Journal of Medicine and were presented during this week’s Late Breaking Clinical Trials session at the European Society of Cardiology Congress in Amsterdam, Netherlands.
 
The trial found the widespread off-label use of CRT in patients with narrow QRS should no longer be used as an option for patients with a QRS below 130 milliseconds, regardless of mechanical dyssynchrony. This trial serves as a reminder that in clinical medicine adequately powered definitive clinical outcome trials are needed before we expand the use of an apparently favorable therapy.
 
“Cardiac resynchronization therapy is a proven treatment for people who have a type of heart failure that includes an electrical abnormality, or a wide QRS complex,” said William Abraham, M.D., director of the division of cardiovascular medicine at The Ohio State University Wexner Medical Center and national co-principal investigator of the study. “We noticed some cardiologists were also trying CRT in heart failure patients who did not have this electrical abnormality, however no large studies had tested the use of CRT in this way.”
 
In 2008, cardiovascular researchers at 115 centers in Europe, Australia and the United States teamed up to test the safety and efficacy of CRT in heart failure patients who had a narrow QRS complex. Patients were enrolled in the study if they had an ejection fraction of 35 percent or less, a narrow QRS duration of 130 milliseconds or less and echocardiographic evidence of a left ventricular dyssynchrony. A total of 809 study participants underwent implantation of a cardiac resynchronization device with defibrillator capability developed by Biotronik. Half (404) were randomized to have CRT turned on while the other half (405) did not receive CRT. All study participants had the defibrillator capability turned on.
 
After following each participant an average of 19 months, the trial was stopped in March on the basis of futility and potential for harm. Researchers recorded 45 deaths and 224 hospitalizations for worsening heart failure in the CRT group compared to 26 deaths and 194 hospitalizations in the control group. 
 
“Not only did cardiac resynchronization not help these patients with systolic heart failure, but the data showed the potential for harm,” said Abraham. “This is a landmark trial in CRT and heart failure because it tells us we should not use this therapy in this group of patients.”
 
Heart failure occurs when the heart does not pump blood efficiently, most often due to a weak heart muscle. Patients suffer from shortness of breath, fatigue, swelling and reduced quality of life. According to the American Heart Association, about 5.7 million Americans have heart failure and it accounts for about 1 million hospital admissions each year at an estimated societal cost of $32 billion.
 
“We’re always looking for better treatments for patients with heart failure to improve their quality of life and reduce their hospitalizations,” said  Ayesha Hasan, M.D., a heart failure cardiologist at Ohio State’s Richard M. Ross Heart Hospital and the lead principal investigator at Ohio State. “We now know expanding the use of CRT in this population of patients is not a positive solution.”
 
Abraham says researchers are still investigating why CRT did not work for this group of patients, to better understand the benefits and challenges of this treatment option.
 
“The EchoCRT trial evaluated an important question for daily clinical practice.  The results will help to guide physicians’ treatment decisions for heart failure patients moving forwards.” said co-lead investigator Johannes Holzmeister, M.D., from University Hospital in Zurich, Switzerland.
Biotronik funded the FDA-approved trial. Abraham is a paid consultant for the company.
 
For more information: bit.ly/1buTeHk
 

Related Content

Synergy stent, abluminal polymer DES, bioresorbable polymer DES, bioresorbable polymer metallic stent

The Synergy stent is the first FDA cleared drug-eluting stent to use a bioresorbable polymer drug carrier. When the polymer dissolves after about four months, the devices become a bare metal stent. The technology is supposed to reduce the rate of late stent thrombosis due to vessel inflammation caused by durable polymers.

Feature | Stents Bioresorbable| January 17, 2017 | Dave Fornell
One of the big advancements in drug-eluting stent (DES) technology has been the development of bioresorbable polymers
St. Jude Medical, Amplatzer Amulet LAA Occluder, observational study, TCT 2016
News | Left Atrial Appendage (LAA) Occluders| November 03, 2016
St. Jude Medical Inc. presented favorable results from the largest observational study to date of the company’s...
Medtronic, CoreValve Evolut R TAVR system, U.S. IDE Study, TCT 2016
News | Heart Valve Technology| November 03, 2016
Medtronic plc unveiled new clinical data showing that patients treated with the self-expanding CoreValve Evolut R...
open-heart surgery, PCI, percutaneous coronary intervention, NOBLE trial, left main coronary artery disease, LMCAD, TCT 2016
News | Cardiovascular Surgery| November 03, 2016
Coronary artery bypass (CABG) surgery is the standard treatment for revascularization in patients with left main...
News | Drug-Eluting Balloons| November 03, 2016
The Spectranetics Corp. announced that it has submitted to the U.S. Food & Drug Administration (FDA) its Pre-Market...
Medtronic, Resolute Integrity DES, drug-eluting stent, BIO-RESORT study, TCT 2016
News | Stents Drug Eluting| November 02, 2016
Investigators recently unveiled clinical data from the independent BIO-RESORT study, representing the first all-comers...
Medtronic, Harmony TPV, transcatheter pulmonary valve, clinical study results, TCT 2016
News | Heart Valve Technology| November 02, 2016
Medtronic plc recently announced new clinical data for the Harmony Transcatheter Pulmonary Valve (TPV) from its early...
Medtronic, Drug-Filled Stent, DFS, RevElution trial, first clinical data, TCT 2016, Stephen Worthley
News | Stents Drug Eluting| November 01, 2016
November 1, 2016 — Medtronic plc unveiled the first clinical outcomes of its novel...
Edwards, Sapien transcatheter heart valve, PARTNER trial, five-year echo data, TCT 2016
News | Heart Valve Technology| November 01, 2016
Edwards Lifesciences Corp. announced new five-year hemodynamic data from the PARTNER Trial demonstrating excellent...
Medtronic, CoreValve Evolut R TAVR system, TCT 2016, FORWARD Study, STS/ACC TVT Registry
News | Heart Valve Technology| October 31, 2016
Medtronic plc presented new positive data from two large registries aimed at evaluating 30-day clinical performance...