Feature | January 12, 2012

Experts Offer Pointers for Optimizing Radiation Dose in Pediatric CT

January 12, 2012 — An article in the January issue of the Journal of the American College of Radiology summarizes methods for radiation dose optimization in pediatric computed tomography (CT) scans. Approximately seven to eight million CT examinations are performed for various pediatric clinical indications per year in the United States.

Justification of clinical indication is the most important aspect of reducing radiation dose with CT scanning. A substantial number of pediatric CT scans lack appropriate justification or can be replaced with other imaging modalities with lower or no ionizing radiation, such as radiography, ultrasonography and magnetic resonance imaging (MRI), which can provide similar diagnostic information for some clinical conditions. 

“When not clinically indicated, not performing a CT examination is certainly the best radiation dose reduction strategy. However, when a CT scan is indicated, there are steps that can be taken to optimize the dose that children receive. It’s important that all imaging providers take these steps as indicated,” said Mannudeep K. Kalra, M.D., author of the article. 

Investigators from Massachusetts General Hospital, Harvard Medical School, in Boston, and Johns Hopkins University in Baltimore, reviewed practical strategies for reducing radiation dose associated with pediatric CT examinations. “Radiation dose reduction in children starts with the optimization of pediatric CT protocols,” said Mahadevappa Mahesh, MS, Ph.D., author of the article. “CT protocols should be strictly optimized on the basis of body size, body region, clinical indication and the availability of prior imaging.”

Additional steps include using a lower tube current and voltage, restricting the scan length to include only the region of interest and using new techniques of image post-processing and reconstruction.   

“Children are more sensitive to radiation-induced risks and need special attention. Therefore, while designing CT protocols, it is crucial to keep clinical indications, weight and prior available imaging in mind to optimize radiation dose,” said Mahesh.

 For more information: www.jacr.org, www.imagewisely.org, www.imagegently.org

Related Content

FFR-CT

An example of a FFR-CT study showing a 3-D reconstruction of the coronary tree and a color overlay of virtual FFR readings, including a severe blockage in need of revascularization in the left anterior decending artery. 

News | CT Angiography (CTA)| August 21, 2015
August 21, 2015 — Loyola University Medical Center is the first and only hospital in Illinois to offer a new, noninva
BioSig Technologies, research agreement, UCLA, Pure EP System, EP lab, ventricular tachycardia model, VT
Technology | EP Lab| August 20, 2015
BioSig Technologies announced it has signed a sponsored research agreement with the regents of the University of...
Corindus, Corpath, radiation dose monitoring, cath lab, vascular robotic system

The Corindus Corpath vascular robotic system.

Technology | Radiation Dose Management| August 19, 2015
Corindus Vascular Robotics Inc. and Unfors RaySafe Inc., a Fluke Biomedical Company, announced a distribution agreement...
Sunshine Heart, COUNTER HF pivotal study, resumes enrollment, C-Pulse, FDA
News | Heart Failure| August 18, 2015
Sunshine Heart Inc. announced an update in late July on its COUNTER HF U.S. pivotal study for the C-Pulse Heart Assist...
Biotronik, BioCONTINUE study, CRT-D, defibrillator, cardiac resynchronization therapy device, heart failure, first replacement
News | Cardiac Resynchronization Therapy Devices (CRT)| August 17, 2015
Biotronik announced that the first patient has been enrolled in the BioCONTINUE clinical trial (BIOtronik study to...
IMRIS, going concern sale, Deerfield Management Company L.P., imaging and service, robotics intellectual property
News | Cath Lab| August 14, 2015
IMRIS Inc. announced in late July that investment funds managed by Deerfield Management Company L.P. (“Deerfield”) were...
Medtronic, Endurant Evo AAA, stent graft system, first European cases
News | Stent Grafts| August 13, 2015
Medtronic plc announced that the first two European patient cases with the Endurant Evo AAA stent graft system were...
zebrafish, iWorx Systems Inc., ZS-200 Zebrafish ECG System, cardiac research
Technology | ECG| August 13, 2015
iWorx Systems Inc., developer of advanced physiology teaching and research instruments and software, has introduced a...
HeartWare, ENDURANCE2 trial, destination therapy, HVAS, HeartWare Ventricular Assist System
News | Ventricular Assist Devices (VAD)| August 11, 2015
HeartWare International Inc. announced that enrollment in the ENDURANCE2 destination therapy clinical trial has been...
ACC, Boehringer Ingelheim, Diabetes Collaborative Registry, American College of Cardiology
News | Cardiac Diagnostics| August 07, 2015
The American College of Cardiology (ACC) has announced that Boehringer Ingelheim is the newest industry sponsor of The...
Overlay Init