News | Magnetic Resonance Imaging (MRI) | August 01, 2019 | Jeff Zagoudis, Associate Editor

FDA Issues Draft Guidance on Medical Device Safety in MRI Environment

Draft guidance document, available for public comment for 60 days, provides suggested standards for testing and labeling of medical devices meant to function in an MRI environment

FDA Issues Draft Guidance on Medical Device Safety in MRI Environment

August 1, 2019 — The U.S. Food and Drug Administration (FDA) issued a new draft guidance titled Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment.

The MR environment presents unique safety hazards for patients and other persons with medical devices near or inside an MR system. This draft guidance, when finalized, is intended to:

  • Provide recommendations on testing for assessing the safety and compatibility of medical devices in the MR environment;

  • Identify test methods that address specific hazards and provide recommended format for MRI Safety Information in medical device labeling; and

  • Submit comments on the draft guidance.

According to the FDA, the guidance document “applies to all implanted medical devices, external medical devices that are fastened to or carried by a patient, and all medical devices that are intended to enter the MR environment.” Contents include recommendations on MR safety and compatibility assessments, as well as key information the agency says should be included in any FDA submissions for the affected devices. The guidance does not apply to the MRI scanner systems themselves. 

In the document, the FDA recommends that the safety and performance of a medical device should be assessed for all of the magnetic field strengths to which that device may potentially be exposed. Some of the potential safety issues covered in the document include: 

  • Magnetically induced displacement force and/or torque (unwanted movement of the device caused by the magnetic field); 

  • Heating of the medical device and/or surrounding tissue, by radiofrequency (RF) induction or switching magnetic field gradients;

  • Gradient induced vibration of the medical device;

  • Unintended stimulation of the device by switching gradient pulses;

  • Medical device malfunction; and

  • Image artifacts.

The FDA explains that all devices should be labeled as either MR-conditional (demonstrated safety in the MR environment within defined conditions), MR safe (poses no known hazards resulting from exposure to any MR environment) or MR unsafe (poses unacceptable risks to the patient,medical staff or other persons within the MR environment). 

This draft guidance will be open for public comments for 60 days at www.Regulations.gov under docket number FDA-2019-D-2837.

Read the full draft guidance document.

For more information: www.fda.gov

Related MRI Safety Content

Cardiac MRI Advances

VIDEO: New App Improves MRI Safety For Implantable Devices

The Changing Relationship Between MRIs and Pacemakers


Related Content

News | Magnetic Resonance Imaging (MRI)

February 21, 2024 — Hyperfine, Inc., a groundbreaking health technology company that has redefined brain imaging with ...

Home February 21, 2024
Home
News | Magnetic Resonance Imaging (MRI)

November 17, 2023 — Researchers from the University of Minnesota Medical School examining the cause of cardiomyopathy ...

Home November 17, 2023
Home
News | Magnetic Resonance Imaging (MRI)

June 28, 2023 — Liver disease, the UK’s third leading cause of premature death, poses a significantly greater threat to ...

Home June 28, 2023
Home
News | Magnetic Resonance Imaging (MRI)

June 20, 2023 — The US Food and Drug Administration has approved the use of iTFlow in blood flow analysis. The FDA ...

Home June 20, 2023
Home
News | Magnetic Resonance Imaging (MRI)

June 7, 2023 — GE HealthCare announced the FDA clearance and launch of Sonic DL – a state-of-the-art deep learning-based ...

Home June 07, 2023
Home
Feature | Magnetic Resonance Imaging (MRI) | By Johnson Polakkal Joseph

Magnetic resonance imaging (MRI) is a technology that has been around for more than four decades and is a staple in ...

Home May 01, 2023
Home
News | Magnetic Resonance Imaging (MRI)

April 18, 2023 — Findings from an award-winning Scientific Online Poster presented during the 2023 ARRS Annual Meeting ...

Home April 18, 2023
Home
News | Magnetic Resonance Imaging (MRI)

April 4, 2023 — Medtronic has announced the launch of MRI Care Pathway, a new system that can streamline the process of ...

Home April 04, 2023
Home
News | Magnetic Resonance Imaging (MRI)

November 17, 2022 — HeartVista, a pioneer in AI-assisted MRI solutions, and Siemens Healthineers, a global leader in ...

Home November 17, 2022
Home
News | Magnetic Resonance Imaging (MRI)

November 9, 2022 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), left ...

Home November 09, 2022
Home
Subscribe Now