News | Heart Valve Technology | November 07, 2017

Harpoon Mitral Valve Repair System Found Safe and Effective

Device may improve quality and frequency of repair

Harpoon Mitral Valve Repair System Found Safe and Effective

November 7, 2017 — A new study has found that a pioneering device to repair heart valves is safe and effective, and can reduce the invasiveness and side effects of conventional mitral valve surgery. The Harpoon Mitral Valve Repair System (H-MVRS), an image-guided device based on technology developed at the University of Maryland School of Medicine (UMSOM), is deployed through a small opening between the ribs, and repairs the heart while it continues to beat. The research was presented at the Transcatheter Cardiovascular Therapeutics (TCT 2017) symposium, Oct. 29-Nov. 2 in Denver, and simultaneously published in the Journal of the American College of Cardiology (JACC).

“The Harpoon device was found to be remarkably safe and effective,” said the study’s principal investigator and an inventor of the device, James S. Gammie, M.D., professor of surgery at UMSOM and chief of cardiac surgery at the University of Maryland Medical Center. “The device allowed the surgeons to precisely and effectively reduce the degree of mitral regurgitation without using an open-heart procedure. There were no deaths. Only one patient needed a blood transfusion, and there were no strokes, no need for pacemakers, no readmission to the ICU and no reintubations,” he said.

Thirty patients with a condition called mitral valve regurgitation (MR) were treated with the device at six clinical centers in Europe, sponsored by the manufacturer of the device, Harpoon Medical Inc., to determine whether the device meets essential European health and safety requirements.

Three patients required conversion to conventional open-heart mitral surgery, including two cases where poor imaging prevented accurate placement of the tool, while 27 met the primary endpoint. At six months, MR was mild or less in 85 percent (22/26) of patients successfully treated with H-MVRS. The repair was associated with restoration of normal valve function and improvement in the heart’s ability to pump blood, according to the researchers, and the operative times for procedures using the device were approximately half those reported for conventional mitral valve repair.

The H-MVRS is an investigational device. It does not have European CE marking and the U.S. Food and Drug Administration has not approved it for use in patients in the United States.

The H-MVRS is designed to treat degenerative MR, the most common type of heart valve disorder. In MR, a leaky valve lets blood travel in the wrong direction on the left side of the heart, causing shortness of breath, fluid retention, irregular heartbeats and fatigue. MR develops when the small fibrous cords that open and close the valve’s flaps, known as leaflets, are broken or stretched, preventing them from closing tightly and causing the leaflets to bulge or prolapse upward toward the left atrium. The natural cords connect the valve flaps to muscles inside the heart that contract to close the mitral valve.

The device anchors artificial cords on the flaps to take the place of the natural cords. The artificial cords are made of expanded polytetrafluoroethylene (ePTFE), a polymer commonly used as sutures in cardiac surgery.

Surgeons insert the device into the beating heart through a tiny opening in the ribcage and, using echocardiographic imaging, guide it to the surface of the defective mitral flaps. When the surgeon determines the optimal placement for an artificial cord, the device is actuated and a specially designed needle makes a tiny hole and sends the cord material through the flap. The needle is then withdrawn and the cord of ePTFE is tightened to form a double-helical knot to hold it in place. The sequence is repeated for the desired number of knots (usually four to six). The other end of the cord is adjusted for optimum length and tied to the outside layer of the heart, the epicardium.

The device was previously tested in Poland. U.S. testing of the device may begin in 2018.

For more information: www.tctconference.com

 

Related Content

TCT 2017 Late-breaking Clinical Trial Presentations


Related Content

News | Cath Lab

December 20, 2023 — Jason R. McCarthy, Ph.D., associate professor of biomedical research and translational medicine and ...

Home December 20, 2023
Home
News | Cath Lab

October 26, 2023 — Royal Philips, a global leader in health technology, announced the latest results demonstrating the ...

Home October 26, 2023
Home
News | Cath Lab

October 25, 2023 — Shockwave Medical, Inc., a pioneer in the development and commercialization of transformational ...

Home October 25, 2023
Home
News | Cath Lab

October 20, 2023 — Over the coming days, Philips will be presenting its latest solutions in cardiology and new late ...

Home October 20, 2023
Home
News | Cath Lab

October 16, 2023 — GE HealthCare (Nasdaq: GEHC) announced US FDA 510(k) clearance of Allia IGS Pulse - the latest ...

Home October 16, 2023
Home
News | Cath Lab

October 16, 2023 — Shimadzu Medical Systems USA, a subsidiary of Shimadzu Corporation, announced the first U.S ...

Home October 16, 2023
Home
News | Cath Lab

September 13, 2023 — A diagnostic test, first offered in the United States at University Hospitals (UH) Harrington Heart ...

Home September 13, 2023
Home
News | Cath Lab

August 2, 2023 — Teleflex Incorporated, a leading global provider of medical technologies, announced the U.S Food and ...

Home August 02, 2023
Home
News | Cath Lab

July 13, 2023 — Mount Sinai Queens announced the opening of a new cardiac catheterization lab that will provide rapid ...

Home July 13, 2023
Home
News | Cath Lab

June 21, 2023 — Royal Philips, a global leader in health technology, announced it has teamed up with BIOTRONIK (Lake ...

Home June 21, 2023
Home
Subscribe Now