1.5T MR Evaluation of Plaque Progression in Carotid Arteries is Feasible

September 1, 2009 - Evaluation of results of a multicenter study indicates that quantitative evaluation of the progression of volume of extracranial carotid vessel walls is feasible with 1.5T magnetic resonance (MR) imaging, despite limitations due to patient motion or habitus.

In the study, Atherosclerotic Plaque Progression in Carotid Arteries: Monitoring with High-Spatial-Resolution MR Imaging — Multicenter Trial, researchers set out to estimate the annualized rate of progression of vessel-wall volume in the carotid arteries in 160 patients by using MR imaging and to establish the fraction of studies that have acceptable image quality.

One hundred sixty patients with greater than 50 percent narrowing of the diameter of the carotid artery were recruited at six centers for prospective imaging of the carotid arteries at baseline and one year later by using high-spatial-resolution, 1.5T MR imaging. Quantitative changes in atheroma volume were measured on unenhanced T1-weighted images. A multiple linear regression analysis was used to correlate progression with several clinical factors, including statin therapy.

All 160 patients completed both baseline and follow-up studies. Of these studies, 67.5 percent were deemed to have image quality that was acceptable for quantitative analysis. The causes of rejection were motion (46 percent), deep location of the carotid artery (22 percent), low bifurcation of the carotid artery (13 percent), and “other” (19 percent). The mean annual change in vessel-wall volume was 2.31 percent. At one-year follow-up, vessel-wall volumes in patients not receiving statin therapy had increased faster compared with those in patients receiving statin therapy: 7.87 percent, plus/minus 13.58 percent vs 1.14 percent, plus/minus 9.9 percent, respectively.

Researchers found that in patients who had preexisting carotid disease, the rate of increase in vessel-wall volume was slower in patients receiving statin therapy.

Reference: Boussel Lo?c, MD, PhD., et al. Atherosclerotic Plaque Progression in Carotid Arteries: Monitoring with High-Spatial-Resolution MR Imaging—Multicenter Trial. Radiology: Volume 252: Number 3—September 2009. radiology.rsnajnls.org.

For more information: www.rsna.org

Related Content

Carotid Artery MRI Improves Cardiovascular Disease Risk Assessment
News | Magnetic Resonance Imaging (MRI) | October 23, 2018
Magnetic resonance imaging (MRI) measurements of wall thickness in the carotid arteries improve cardiovascular disease...
FDA Clears Magnetom Sola 1.5T MRI From Siemens Healthineers
Technology | Magnetic Resonance Imaging (MRI) | October 09, 2018
The U.S. Food and Drug Administration (FDA) has cleared the Magnetom Sola, a 1.5 Tesla magnetic resonance imaging (MRI...
Stress Cardiac MRI Shows High Prognostic Value for Suspected Ischemia Patients
News | Magnetic Resonance Imaging (MRI) | September 17, 2018
Raymond Kwong, M.D., MPH, from the Harvard Medical School recently presented his findings on a study of how single-...
Rapid Cardiac MRI Technique May Cut Costs, Boost Care in Developing World
News | Magnetic Resonance Imaging (MRI) | August 29, 2018
A newly developed rapid imaging protocol quickly and cheaply diagnosed heart ailments in patients in Peru, according to...
Videos | Magnetic Resonance Imaging (MRI) | August 13, 2018
Haojie Wang, M.D., director of advanced cardiovascular MRI and a member of the heart valve clinic at Baylor Scott Whi
High Prevalence of Atherosclerosis Found in Lower Risk Patients
News | Magnetic Resonance Imaging (MRI) | June 08, 2018
Whole-body magnetic resonance angiography (MRA) found a surprisingly high prevalence of atherosclerosis in people...
A cardiac MRI scanner at the Houston Methodist DeBakey Heart and Vascular Center. There is growing concern that gadolinium contrast may cause chronic health problems in some patients.

A cardiac MRI scanner at the Houston Methodist DeBakey Heart and Vascular Center. There is growing concern that gadolinium contrast may cause chronic health problems in some patients.

Feature | Magnetic Resonance Imaging (MRI) | February 28, 2018 | Dave Fornell
One of the biggest concerns in radiology in recent years is the safety of gadolinium-based contrast agents (GBCAs) us
Contrast-Free Cardiac MRI May Better Assess Need for Mitral Valve Surgery
News | Magnetic Resonance Imaging (MRI) | February 27, 2018
A new study published in the Journal of the American College of Cardiology confirms non-invasive cardiac magnetic...
The FDA has cleared the Toshiba Vantage Galan 3.0T XGO Edition MRI from Canon Medical Systems.
Technology | Magnetic Resonance Imaging (MRI) | February 12, 2018
February 12, 2018 — Physicians now have access to more neuro and cardiac ...
Overlay Init