Feature | Magnetic Resonance Imaging (MRI) | October 29, 2020

Cardiac MRI Contrast Agents Carry Low Risk of Adverse Events

Researchers analyzed data from 154,779 patients who underwent cardiac MRI, 95% of whom received a gadolinium-based contrast agent

This study found cardiac MRI gadolinium-based contrast agents are safe for patient use. Overall, there were only 556 acute adverse effects in 145,855 contrast-enhanced MRIs, with only 47 being classified as severe.

This study found cardiac MRI gadolinium-based contrast agents are safe for patient use. Overall, there were only 556 acute adverse effects in 145,855 contrast-enhanced MRIs, with only 47 being classified as severe. 


October 29, 2020 — Contrast agents used to improve views of the heart on magnetic resonance imaging (MRI) carry a very low risk of allergic reactions, vomiting and other acute adverse events, according to a large study from Europe published in Radiology: Cardiothoracic Imaging.[1] The findings come three years after the European Union enacted new regulations on the contrast agents.

Cardiac MRI is a well-established tool for heart imaging. The majority of cardiac MRI exams use intravenous gadolinium-based contrast agents (GBCAs) to improve visualization of the heart muscle and blood flow. Contrast-enhanced MRI is often used to assess scars to the heart tissue and detect cardiac ischemia, a condition of reduced blood flow to the heart resulting from blockage of the coronary arteries. Contrast-enhanced cardiac MRI is also frequently used to evaluate diseases like cardiomyopathy and myocarditis.

GBCAs rely on an ion of the heavy metal gadolinium to work. Since the ion is toxic to humans, it is bound in a molecule called a ligand to make it safe. GBCAs are classified as either linear or macrocyclic based on the type of ligand used. Linear GBCAs have elongated ligands, while macrocyclic GBCAs have a cage-shaped ligand that traps the gadolinium ion inside.

Studies have shown that trace amounts of the toxic gadolinium ions may remain in the body following repeated GBCA administration. Linear GBCAs are thought to have a higher likelihood of deposit compared to macrocyclic GBCAs, as the macrocyclic GBCAs offer better containment of the gadolinium ion and are considered more stable.

“Studies have demonstrated that the likelihood and extent of cerebral gadolinium depositions are increased after administration of linear GBCAs compared to macrocyclic GBCAs, although the clinical relevance of these depositions still needs to be determined,” said the study’s lead author, Johannes Uhlig, M.D., M.P.H., from University Medical Center in Goettingen, Germany.

As a preventive measure, in late 2017 the European Medicines Agency (EMA) suspended the marketing authorization of linear GBCA types except in liver imaging.

For the new study, Uhlig and colleagues tapped into the multinational, multicenter European Society of Cardiovascular Radiology MRCT Registry to assess the impact of the EMA’s regulatory decision. The study group included 154,779 patients who underwent cardiac MRI, with almost 95% receiving GBCA. While linear GBCAs were used in 15.2% of examinations before and in 2017, their use decreased to less than 1% in 2018 and 2019.

They also tracked GBCA-associated acute adverse events and classified them as mild, moderate or severe. Mild events included allergic reactions such as hives and wheezing, while reactions like chest pain and arrhythmia were classified as moderate or severe. Overall, there were 556 acute adverse effects in 145,855 contrast-enhanced MRIs, or 0.38%, with only 47 being classified as severe.

“Using a large-scale patient cohort from several European countries, our study demonstrates that the administration of GBCA for cardiac MRI is safe for the overwhelming majority of patients,” Uhlig said. “In particular, macrocyclic GBCAs exhibit a favorable acute safety profile, and should be considered for cardiac MRI examinations evaluating myocardial scarring, ischemia, cardiomyopathy and myocarditis.”

Adverse events occurred even without GBCA administration. Out of the 8,924 cases in the study group that did not involve GBCAs, 231 examination-related events were reported, or 2.59%, the majority being anxiety and shortness of breath.

The results underscore the importance of pre-procedural assessment to look for contraindications to MRI scanning and GBCA administration, as well as the likelihood of GBCA-associated adverse events, Uhlig said.

“Potentially vulnerable populations include those with orthostatic shortness of breath, prior adverse GBCA reactions and terminal renal insufficiency,” he said.

Policies on linear GBCAs vary internationally. No regulatory restrictions have been issued in the United States, although the U.S. Food and Drug Administration (FDA) recommends that physicians consider gadolinium retention characteristics when choosing GBCAs. Because of their unique properties, linear GBCAs are still considered vital for liver imaging.

“Although there are efforts to advance non-contrast hepatic imaging, linear GBCAs will probably be indispensable for specific patient populations in the near future,” Uhlig said.

The study authors credited the MRCT Registry for helping make their research possible.

“These analyses highlight the importance of establishing and maintaining large-scale prospective data registries, specifically in the field of radiology,” said the study’s senior author Matthias Gutberlet, M.D., one of the MRCT Registry co-founders.

“Gadolinium-based Contrast Agents for Cardiac MRI: Use of Linear and Macrocyclic Agents with Associated Safety Profile from 154,779 European Patients.” Collaborating with Drs. Uhlig and Gutberlet were Omar Al-Bourini, M.D., Rodrigo Salgado, M.D., Marco Francone, M.D., Ph.D., Rozemarijn Vliegenthart, M.D., Ph.D., Jens Bremerich, M.D., and Joachim Lotz, M.D.

 

Related Content on Gadolinium Contrast Safety:

The Debate Over Gadolinium MRI Contrast Toxicity

VIDEO: Big Concerns Remain for MRI Gadolinium Contrast Safety — An interview with Emanuel Kanal, M.D.

FDA Approves Bayer's Gadavist Contrast for Cardiac MRI in Adult Coronary Artery Disease Patients

VIDEO: Artificial Intelligence May Help Reduce Gadolinium Dose in MRI

Subtle Medical Receives FDA 510(k) Clearance for AI-powered SubtleMR

VIDEO: Managing Gadolinium Safety — Interview with Lawrence Tanenbaum, M.D.

Artificial Intelligence Processes Provide Solutions to Gadolinium Retention Concerns

MRI's Environmental Impact

VIDEO: How Serious is MRI Gadolinium Retention in the Brain and Body? An interview with Max Wintermark, M.D.

Radiology Has Failed to Properly Assess or Track MRI Gadolinium Contrast Safety

Recent Developments in Contrast Media

FDA Committee Votes to Expand Warning Labels on Gadolinium-Based Contrast Agents

European Medicines Agency Issues Update on Gadolinium Contrast Agents

ISMRM Issues Guidelines for MRI Gadolinium Contrast Agents

FDA: No Harm in MRI Gadolinium Retention in the Brain

VIDEO: MRI Gadolinium Contrast Retention in the Brain

Gadolinium May Remain in Brain After Contrast MRI

 

Reference:

1. Johannes Uhlig, Omar Al-Bourini, Rodrigo Salgado, Marco Francone, Rozemarijn Vliegenthart, Jens Bremerich, Joachim Lotz, Matthias Gutberlet. Gadolinium-based Contrast Agents for Cardiac MRI: Use of Linear and Macrocyclic Agents with Associated Safety Profile from 154 779 European Patients. Radiology: Cardiothoracic Imaging. Published online Oct 29 2020. https://doi.org/10.1148/ryct.2020200102. 

 


Related Content

News | Cardiac Imaging

July 11, 2023 — Hyperfine, Inc., the groundbreaking medical device company that created the Swoop system, the world’s ...

Home July 11, 2023
Home
Feature | Cardiac Imaging | By Matthew Jay Budoff, MD, FACC, FAHA

Coronary computed tomography angiography (CCTA) is cheaper, easier to use and its results are easier to understand than ...

Home July 10, 2023
Home
News | Cardiac Imaging

June 29, 2023 — According to an accepted manuscript published in ARRS’ own American Journal of Roentgenology (AJR) ...

Home June 29, 2023
Home
News | Cardiac Imaging

June 26, 2023 — Jubilant DraxImage Inc., dba Jubilant Radiopharma, a wholly-owned subsidiary of Jubilant Pharma Limited ...

Home June 26, 2023
Home
News | Cardiac Imaging

June 15, 2023 — Dr. Jonathan Weinsaft, an esteemed physician-scientist who focuses on clinical research and ...

Home June 15, 2023
Home
News | Cardiac Imaging

June 9, 2023 — According to an accepted manuscript published in ARRS’ own American Journal of Roentgenology (AJR) ...

Home June 09, 2023
Home
Feature | Cardiac Imaging | By Mohammad Sahebjalal, MD

Invented in 1896 by Enrico Salvioni, the fluoroscope remains a flagship technology of modern medicine. The live video X ...

Home May 04, 2023
Home
News | Cardiac Imaging

April 26, 2023 — In the majority of cases, graft failure after heart transplantation is attributable to abnormalities ...

Home April 26, 2023
Home
News | Cardiac Imaging

April 14, 2023 — Genetesis, Inc., the leader in biomagnetic cardiac imaging solutions, today announced that the U.S ...

Home April 14, 2023
Home
News | Cardiac Imaging

February 8, 2023 — Carestream Health is partnering with Robarts Research Institute to increase and demonstrate the ...

Home February 08, 2023
Home
Subscribe Now