Feature | May 12, 2015

Smarter, Cheaper Technologies Offer Improved Point-of-Care Medicine

May 12, 2015 — A team from Stanford University School of Medicine has developed and combined new paper and flexible polymer substrates with special sensing devices for rapid and accurate detection of pathogens such as HIV and other biotargets. These novel technologies offer the type of robust, simple, and inexpensive biosensing systems required to provide point-of-care healthcare in remote areas, where there is minimal diagnostic infrastructure or equipment and a lack of trained medical technicians.

The Bio-Acoustic MEMS in Medicine Labs team developed assays for the simple and rapid detection of HIV-1, various bacteria and CD4+ T lymphocytes. The assays for pathogens and cells were used as proof of concept to demonstrate the utility of several new detection and sensing technologies.

Overall, the group has developed platforms and sensing devices that are easy to make, easy to use and can be safely disposed of after use — characteristics necessary for developing affordable tools with broad applications in both developed and developing countries. The work is reported in the March 6 edition of Nature Scientific Reports.

“The group is simultaneously developing multiple novel methods that target important diseases in underserved communities,” said Tiffani Lash, Ph.D., director of the NIBIB Program in Point-of-care Technologies. “Their comprehensive approach is resulting in smarter, inexpensive technologies that can be applied to a wide range of healthcare problems and settings.”

Testing for HIV-1 in whole blood

Current tests for HIV infection detect antibodies to HIV in the individual’s blood. However, because it takes up to several months for those antibodies to form, these tests do not detect individuals in the earliest stage of infection when they are most likely to pass on the disease. In order to detect HIV-1 in recently infected individuals, the researchers developed an assay that can detect the presence of the virus in whole blood or plasma.

The platform is a disposable flexible polyester chip with implanted electrodes. HIV-1 antibodies are added to whole blood or plasma where they bind to the virus, creating aggregates of antibody and viral lysate. When added to the flexible chip, the aggregates change the electrical conductivity of the chip, which gives a simple electrical readout indicating that the sample contains HIV-1. In addition to detecting early-stage infection, the electrical readout is much simpler and less expensive than current assays. The researchers estimate the cost is about $2 per test and can be safely disposed of after use.

CD4+ T Lymphocyte capture and detection

Accurate CD4+ T cell count is essential for HIV-1 diagnosis and treatment monitoring. World Health Organization guidelines recommend antiretroviral therapy for individuals with a CD4+ T cell count of less than 500 cells/ml. Conventional CD4+ T cell counting methods require an expensive flow cytometer, a skilled operator and costly reagents. A disposable and flexible biosensing platform for efficient counting of CD4+ T cells has potential to address some of these global health challenges in the point-of-care setting.

The approach used by the research team to develop a simple, inexpensive assay for CD4+ T cell count involved two novel technologies: a polyester film with microfluidic channels to capture the T cells, and a detection technology known as lensless shadow imaging. The microfluidic channels were coated with an antibody that captures the CD4+ T cells. A single drop of whole blood from a fingerprick was applied to the polyester film, where capillary forces pull the blood into the microfluidic channels. The shadow of the CD4+ T cells that adhere to the channels can then be visualized on the polyester film. Overall, the platform allows efficient CD4+ T cell counting using fingerprick volume of unprocessed whole blood samples on disposable film at the point-of-care. This platform has the potential to replace the current use of non-disposable glass platforms that require additional steps and expense to visualize the cells with a fluorescent tag.

Using a cell phone to detect and quantify bacteria

E. coli and S. aureus are the most common bacterial pathogens that cause food poisoning, skin infections and blood infections. The group developed a sensitive biosensing platform that detects E. coli by the aggregation of nanoparticles on cellulose paper.

Gold nanoparticles are covered with surface molecules that bind to E. coli bacteria. When the test fluid containing bacteria is mixed with the nanoparticles and transferred to the cellulose paper, the aggregation results in a blue spot. If bacteria are not present, there is no aggregation and the solution applied to the cellulose paper turns red. Thus the presence or absence of bacteria can be seen immediately. Further, the group was able to determine the concentration of E.coli in the sample by taking a picture of the blue spot on the paper with a cell phone and using an imaging analysis tool to measure red pixel intensity of the picture. Concentrations of E. coli could be quantified ranging from 8 to 1.5 million bacteria per milliliter. Further, the platform provides a multiplexed capability and can be applied to other bacteria such as S. aureus.

“The goal of our work,” said Utkan Demirici, Ph.D.., of the Demirici Bio-Acoustic-MEMS in Medicine Laboratory at Stanford School of Medicine, “is to simplify the techniques that both capture the biotarget and detect that captured target. Both aspects of a simplified test must be addressed to move this type of work forward to practical use in low resource settings. These platform technologies can be potentially broadly applied to other diseases such detecting oncogenic viruses such as KSHV, HPV, HBV and HCV, which we also need to be monitored in the developed world settings at a primary care physicians office or during a dental appointment or at the bedside.”

For more information: www.nibib.nih.gov

Related Content

Florida Medical Center First in State to Offer High Sensitive STAT Blood Test
News | Blood Testing | September 07, 2017
In July, The Heart Institute at Florida Medical Center became the first hospital in the state of Florida to offer the U...
Patients With Low Corus CAD Test Score Less Likely to Undergo Cardiac Referra
News | Blood Testing | May 02, 2017
CardioDx Inc. recently announced the publication of results from the multi-center, community-based PRESET Registry in...
New Blood Test Predicts Major Cardiac Events Better Than Clinical Evaluation of Other Common Risk Factors
News | Blood Testing | April 28, 2017
Prevencio Inc. announced the publication of data demonstrating that a simple new blood test is more accurate than...
New Study Pursues Universal Sample Bank for Troponin Tests
News | Blood Testing | April 13, 2017
April 13, 2017 — A study published recently in the American Association for Clinical Chemistry’s (AACC)...
PTS Diagnostics, FDA 510k clearance, extended HDL range, lipid panel test strips
News | Blood Testing | April 05, 2017
PTS Diagnostics announced that the U.S. Food and Drug Administration (FDA) has cleared an expanded top range for...
heart attack evaluation, blood test, HEART Score, ER, emergency room, Circulation Cardiovascular Quality and Outcomes study
News | Blood Testing | March 01, 2017
Up to 40 percent of emergency room (ER) patients with chest pain can safely go home in a little under 2 hours, using a...
troponin blood test, heart disease risk, heart attack, British Heart Foundation, BHF
News | Blood Testing | January 04, 2017
A high-sensitivity blood test could be used to predict which patients are at risk of a heart attack according to new...
Alere, INRatio PT/INR Monitor, voluntary recall, FDA
News | Blood Testing | July 12, 2016
July 12, 2016 — Following a collaborative process with the U.S. Food and Drug Administration (FDA), Alere Inc.
News | Blood Testing | March 22, 2016
March 22, 2016 — Critical Diagnostics announced that it entered into a license agreement for the exclusive worldwide