News | Heart Valve Technology | March 07, 2018

FDA Expands Approval of Replacement Heart Valve

This replacement heart valve is the smallest mechanical valve size approved in the world

The U.S. Food and Drug Administration expanded the approval of a heart valve to include a size small enough to be used in newborn pediatric patients to treat heart defects.

The U.S. Food and Drug Administration expanded the approval of a heart valve to include a size small enough to be used in newborn pediatric patients to treat heart defects. Specifically, the agency approved the Masters Series Mechanical Heart Valve with Hemodynamic Plus (HP) Sewing Cuff to include the 15-mm valve size, making it the smallest mechanical heart valve approved in the world.

“While larger replacement heart valves have been approved for years, there is an unmet need in young pediatric patients, especially newborns and infants, with congenital valve defects who may be too small to use currently-marketed heart valves,” said Jeff Shuren, M.D., J.D., director of the FDA’s Center for Devices and Radiological Health.

Heart valve disease occurs if one or more of the four heart valves, which direct the flow of blood through the heart, fail to function properly. In pediatric patients, a malfunctioning heart valve is often the result of a congenital heart defect at birth. Each year, more than 35,000 babies in the U.S. are born with congenital heart defects, some of which will require heart valve surgery and, potentially, replacement heart valve surgery. However, prior to today’s approval, there have been limited replacement heart valve options available because of the patients’ small size. The Masters Series 15-mm HP valve represents an important treatment option for these patients.

The Master Series Mechanical Heart Valve is a rotatable, bileaflet (two-leaflet) valve designed for implantation in the aortic or mitral position. The bileaflet design consists of two semi-circular discs that open and close in response to blood pressure changes during the heartbeat, similar to a patient’s own valve.

The Masters Series Mechanical Heart Valve was first approved in 1995 for patients with a diseased, damaged or malfunctioning aortic or mitral heart valve. The device is also approved for use in replacing previously implanted aortic or mitral prosthetic heart valves. Today’s approval expands the range of valve sizes available, providing smaller patients another treatment option.

The FDA evaluated clinical data from a single-arm study of 20 pediatric patients with serious heart failure ranging in age from 1.5 weeks to 27 months at the time of mitral valve implant. The data showed that one year after the implant procedure, the probability of survival was 69.3 percent and the probability of not experiencing a valve-related adverse event was 66.8 percent. Serious valve-related adverse events observed during the study through one-year follow-up included blood clots in the device and bleeding in the brain. Anticoagulation (blood thinning) therapy may be necessary after the procedure, to prevent clotting on the device, which can increase the risk of bleeding.

The Master Series Mechanical Heart Valve should not be used by patients unable to tolerate anticoagulation therapy.

The FDA granted approval of the Master Series Heart Valve to St. Jude Medical. 

For more information: www.fda.gov

Related Content

First TriCinch Coil Tricuspid Repair Systems Implanted in U.S.
News | Heart Valve Technology | November 06, 2018
4Tech Inc. initiated its U.S. Early Feasibility Study of the TriCinich Coil System following U.S. Food and Drug...
Valve Replacement Volume Key to Successful Patient Outcomes
News | Heart Valve Technology | November 02, 2018
Hospitals that routinely perform a heart valve replacement procedure requiring open heart surgery are more likely to...
Prosthetic Valve Mismatches Common in TAVR Procedures
News | Heart Valve Technology | October 03, 2018
A high number of patients in a study who underwent transcatheter aortic valve replacement (TAVR) experienced severe and...
Local Anesthesia Safe and Effective for Intermediate- and High-Risk TAVR Patients
News | Heart Valve Technology | September 28, 2018
The first randomized study to compare general versus local anesthesia during transcatheter aortic valve replacement (...
MitraClip Reduces Mortality for Heart Failure Patients With Secondary Mitral Regurgitation
News | Heart Valve Technology | September 26, 2018
Patients with heart failure and secondary mitral regurgitation (MR) who remained symptomatic despite maximally...
Ancora Heart Announces Positive Interim Analysis of AccuCinch Ventricular Repair System for Heart Failure
News | Heart Valve Technology | September 24, 2018
Ancora Heart Inc. announced positive clinical data from the company’s recently expanded U.S. early feasibility study...
Medtronic Announces TAVR Study of Aortic Stenosis Patients With Bicuspid Valves
News | Heart Valve Technology | September 19, 2018
The U.S. Food and Drug Administration (FDA) has approved an investigational device exemption (IDE) to initiate a new...
4C Medical's AltaValve First-in-Human Experience to be Presented at TCT 2018
News | Heart Valve Technology | September 17, 2018
September 17, 2018 — 4C Medical Technologies Inc.
Gore Acquires Pipeline Medical Technologies Inc.
News | Heart Valve Technology | September 06, 2018
W. L. Gore & Associates Inc. (Gore) announced the acquisition of Pipeline Medical Technologies Inc., a privately...
Overlay Init