News | Defibrillator Monitors | April 16, 2018

Rice University Students Improve AED Operation With Needle Pad

Add-on pad punches through the skin to deliver a more effective shock

Rice University Students Improve AED Operation With Needle Pad

The automated external defibrillator add-on developed by Rice University students is a pad of needles that break through the skin's natural impedance barrier to deliver an electric shock to the heart of a patient in cardiac arrest. (Credit: Jeff Fitlow/Rice University)

April 16, 2018 — The skin presents a formidable barrier to life-saving defibrillators, but a team of students from Rice University believes it has found a way around that problem.

Or, more to the point, through.

The Zfib team of Rice senior bioengineering students created an add-on for automated external defibrillators (AEDs) that literally punches through the skin to help deliver a jolt to a person in cardiac arrest.

With the help of advisers Eric Richardson, a Rice bioengineering lecturer, and Mehdi Razavi, M.D., a cardiologist at Texas Heart Institute, the students developed a needle-laden pad that can be pressed through both a flexible AED pad and the skin to overcome the skin's typical impedance of around 500 kilo ohms per square centimeter.

In practice, AED users would apply AED pads to the exposed skin of a patient's chest and side, just as they are trained to do in thousands of AED/CPR classes taught in the U.S. each year. The needles would then be pressed through a pad and the patient's skin to bloodlessly deliver a more effective shock.

By the team's measurements, the add-ons reduce the skin's impedance by 72 percent. That, in turn, should increase a patient's chance of survival and reduce the odds that the patient will need multiple shocks.

"We looked into other ways to break the skin impedance, and some of the things we saw used chemicals or abrasion, like a sandpaper material," team member Billy Jeon said.

"But in an emergency situation, you wouldn't want to mess around with chemicals or something very complicated," said Alexander Lu. "With needles, you just push straight down and it's pretty effective."

The team — which also includes Jamie Leong, Natalie Bolton and Sylvia Cai — was inspired by insulin-delivery patches that break through the skin with microneedles.

The Zfib add-on is a 3-D printed plastic frame with a rubber backing that allows the user to press 180 tiny needles into a patient's chest without having to touch the needles. The needles collect current from the side of the pad that touches the skin and deliver it to the patient. Indicators on top of the device turn green when enough pressure is applied.

"These needles only go 1 to 2 millimeters into the skin, so it's not very far," Cai said. "They go just past the epidermis and into the dermis. There's no blood drawn."

The needles have to do their job without interfering with the AED's ability to monitor the heart's rhythm and decide whether a shock is necessary, according to the team. The current also has to be kept low enough to prevent burns.

"There are papers and clinical studies from the past 10 or 20 years about how people have gotten second- and third-degree burns from AED pads," Lu said.

"We had to calculate how many needles we needed based on surface area," Leong said. "We ran into the problem of putting so many needles on that it distributed the force and wouldn't break the skin, like a bed of nails."

Once they settled on 180 needles, the team evaluated their design with tests on artificial skin, an animal cadaver – and on Jeon.

"We actually hooked our device – really lightly! – onto Billy to see if it would pick up his rhythm, and it worked," Leong said.

For more information: www.oedk.rice.edu

 

Related Content

The Zoll LifeVest wearable defibrillator was the subject of the VEST Trial

The Zoll LifeVest wearable defibrillator system was evaluated in the late-breaking VEST Trial presented at ACC 2018 earlier this year.

Feature | Defibrillator Monitors | July 10, 2018 | Michael J. Mirro, M.D.
Following the...
Zoll Canada Equipping Province of Québec Paramedic Services with X Series Monitor/Defibrillators
News | Defibrillator Monitors | October 16, 2017
October 16, 2017 — Zoll Canada, a subsidiary of Zoll Medical Corp., announced it has won the tender to equip all ambu
Physio-Control Launches HeartSine samaritan PAD 360P Automated External Defibrillator in United States
Technology | Defibrillator Monitors | April 24, 2017
Physio-Control announced April 19 that the company’s HeartSine samaritan PAD 360P (SAM 360P) fully automatic external...
AEDs, automated external defibrillators, requirements, U.S. schools, JACC study
News | Defibrillator Monitors | March 30, 2017
Automated external defibrillators (AEDs) are associated with increased survival of sudden cardiac arrest when installed...
Philips, FDA, class I recall, HeartStart MRx Monitor/Defibrillator
News | Defibrillator Monitors | March 28, 2017
Philips and the U.S. Food and Drug Administration (FDA) announced the company has initiated a recall of its HeartStart...
Zoll, Hospital Wearable Defibrillator, HWD, FDA premarket approval
Technology | Defibrillator Monitors | March 10, 2017
Zoll Medical Corp. announced that the company’s Hospital Wearable Defibrillator (HWD) has been granted premarket...
Zoll LifeVest wearable defibrillator, WEARIT-II Registry results, CardioStim EuroPace 2016
News | Defibrillator Monitors | June 21, 2016
Zoll Medical Corp. announced that patients experience a high one-year survival rate following use of the LifeVest...
defibrillator-monitors, defibrillator monitor

Physio-Control's LifePAK15

Feature | Defibrillator Monitors | February 03, 2014 | Dave Fornell
For U.S. hospitals and emergency medical services (EMS) looking to upgrade their aging defibrillator-monitors, new...
Overlay Init