Technology | Magnetic Resonance Imaging (MRI) | October 12, 2017

FDA Clears Siemens Magnetom Terra 7T MRI Device

Device is the first 7T MRI cleared for clinical use in the United States

FDA Clears Siemens Magnetom Terra 7T MRI Device

The FDA has cleared the Siemens Magnetom Terra as the first 7T MRI system in the U.S. to gain regulatory approval.

FDA Clears Siemens Magnetom Terra 7T MRI Device
FDA Clears Siemens Magnetom Terra 7T MRI Device

October 12, 2017 — The U.S. Food and Drug Administration (FDA) cleared the first 7 Tesla (7T) magnetic resonance imaging (MRI) device, more than doubling the static magnetic field strength available for use in the United States. The Magnetom Terra from Siemens Healthineers is the first 7T MRI system cleared for clinical use in the United States.

“The overall image quality of MRI improves with higher magnetic field strength,” said Robert Ochs, Ph.D., director of the Division of Radiological Health in the FDA’s Center for Devices and Radiological Health. “The added field strength allows for better visualization of smaller structures and subtle pathologies that may improve disease diagnosis.”

MRI scanners use strong magnetic fields and radio waves (radiofrequency energy) to generate images. The signal comes mainly from the protons in fat and water molecules in the body. When interpreted by a trained physician, images from an MRI scan provide information that may be useful in determining a diagnosis. MRI scanners come in different magnet field strengths measured in tesla or “T.” Before today’s clearance, clinical MRI systems were available in field strengths of 3T and below.

The FDA reviewed the Magnetom Terra through the 510(k) premarket clearance pathway. The FDA based its clearance on comparison to a predicate device and acquisition of sample clinical images. The agency reviewed the safety of the radiofrequency subsystem through computational modeling, simulations and rigorous experimental validation. The manufacturer also provided data from a comparative study of 35 healthy patients that compared images of the patients using the 7T device and images using the 3T device. Board-certified radiologists reviewed the images and confirmed that the images acquired on the 7T device were of diagnostic quality and, in some cases, an improvement over imaging at the 3T.

This advanced ultra-high-field scanner produces cross-sectional images of the head and knee, and is intended for patients over 66 lbs. The system’s neurological and musculoskeletal (MSK) applications have the potential to help physicians achieve unprecedented breakthroughs in clinical care by revealing functional and anatomical details not visible at lower magnet field strengths.

The ultra-high-field scanner is indicated for patients who weigh more than 66 pounds and is limited to examinations of the head, arms and legs (extremities).

Siemens said the system’s neurological and musculoskeletal (MSK) applications have the potential to help physicians achieve unprecedented breakthroughs in clinical care by revealing functional and anatomical details not visible at lower magnet field strengths. 

The system has a unique dual mode feature, which permits the user to switch for the first time ever between an investigational “research mode” and a 510(k)-cleared “clinical mode” for imaging, while keeping research data and clinical images safe on separate databases, respectively. The scanner delivers superior images with up to 64 receive channels and more than twice the signal-to-noise (SNR) ratio of 3T MRI in optimized 7T neuro and MSK clinical applications. Its 80/200 gradients provide high levels of power to not only perform diffusion MRI and functional MRI (fMRI), but also to utilize the company’s Simultaneous Multi-Slice (SMS) application to accelerate advanced neurological applications for clinical routine. Its ultrafine 0.2 mm in-plane anatomical resolution potentially enables visualization of previously unseen anatomical structures.

For example, cerebral cortex imaging at 0.2 mm in-plane resolution may yield never-before-visible clinical details in cortical structure, Siemens said. The scanner’s submillimeter BOLD fMRI contrast increases linearly with field strength, which may translate in clinical use to higher resolution in neuro imaging compared to 3T applications.

The scanner has two coils optimized for clinical neuro and knee imaging. The MRI scanner leverages the syngo MR E11 software platform from Siemens Healthineers, enabling users to work in the same manner as they would with the company’s 1.5T and 3T technology. The Magnetom Terra also features the hyper-fast image reconstruction technology of the MaRS (Measurement and Reconstruction System) computer, for speeds up to 20 times faster than previous generations of 7T research scanners. 

Siemens said the system has the ability to expand research capabilities, giving research centers a competitive edge and to support reputations as a key opinion leader. Currently, the vendor said more than 65 percent of 7T MRI scanners worldwide are from Siemens. In the United States, six hospitals have installed Siemens 7T systems for research purposes

Siemens said the 7T system is designed for fast installation in clinical environments and will enable reduced operating costs thanks to design that has zero helium boil-off. 

“With the Magnetom Terra 7T scanner, Siemens Healthineers proudly introduces the first MRI field strength above 3T to be cleared for clinical imaging in nearly 20 years,” said Christoph Zindel, M.D., senior vice president and head of magnetic resonance at Siemens Healthineers. “Armed with the Magnetom Terra’s ultra-high-field strength, clinicians may be able to achieve new, unforeseen levels of patient care and clinical advancements through improved visualization of a wide variety of neurological disease states.”

For more information: https://usa.healthcare.siemens.com/magnetic-resonance-imaging/7t-mri-scanner/magnetom-terra/features#02161187_EN_US

 

Watch the VIDEO Magnetic Resonance Imaging (MRI) Technology Report from RSNA 2016.

Related Content

Cardiac MR, also called cardiac MRI or heart MRI, can offer data above and beyond anatomical imaging.

Cardiac MR can offer data above and beyond anatomical imaging, which is the main reason why this system was installed at Baylor Scott White Heart Hospital in Dallas. The system is a dedicated heart MRI scanner.

Feature | Magnetic Resonance Imaging (MRI) | February 19, 2020 | Dave Fornell, Editor
Videos | Magnetic Resonance Imaging (MRI) | December 20, 2019
James Carr, M.D., chair of the Department of Radiology, Northwestern University, and incoming 2020 President of the...
Greater Left Ventricular Mass Increases Risk of Heart Failure
News | Magnetic Resonance Imaging (MRI) | October 21, 2019
Elevated left ventricular mass, known as left-ventricular hypertrophy, is a stronger predictor of coronary artery...
Heart MRI example. An example of a cardiac MRI exam showing perfusion defects in the heart muscle, amount of infarct and edema and a score for myocardial salvage which can help determine if revasularization will help restore heart function.

A example of a cardiac MRI exam showing perfusion defects in the heart muscle, amount of infarct and edema and a score for myocardial salvage, which can help determine if revasularization will restore heart function following a heart attack.

News | Magnetic Resonance Imaging (MRI) | October 07, 2019
October 7, 2019 – A recent study published in the New England Journal of Medicine supports the use of
Machine Learning Could Offer Faster, More Precise Cardiac MRI Scan Results
News | Magnetic Resonance Imaging (MRI) | September 25, 2019
Cardiac magnetic resonance imaging (MRI) analysis can be performed significantly faster with similar precision to...
Haojie Wang, M.D., director of advanced cardiovascular MRI and a member of the heart valve clinic at Baylor Scott White Heart Hospital, Dallas. His hospital installed a dedicated cardiac Siemens 1.5T MRI scanner in 2018 because MRI offers soft tissue visualization not available on CT or ultrasound.

Haojie Wang, M.D., director of advanced cardiovascular MRI and a member of the heart valve clinic at Baylor Scott White Heart Hospital, Dallas. His hospital installed a dedicated cardiac Siemens 1.5T MRI scanner in 2018 because MRI offers soft tissue visualization not available on CT or ultrasound.

Feature | Magnetic Resonance Imaging (MRI) | September 06, 2019 | Jeff Zagoudis, Associate Editor
Traditionally, computed tomography (CT) and ultrasound have been the workhorse imaging modalities in the world of car
Displacement comparison at the end-systolic frame and final frame

Displacement comparison at the end-systolic frame and final frame. The three patients (V6, V10, V16) with different left-ventricle walls are shown. Point-to-surface distance is a measure to estimate the distance of a point from the reference surface. Image courtesy of WMG, University of Warwick

News | Magnetic Resonance Imaging (MRI) | August 28, 2019
A new 3-D magnetic resonance imaging (MRI) computing technique developed by scientists in WMG at the University of...
FDA Issues Draft Guidance on Medical Device Safety in MRI Environment
News | Magnetic Resonance Imaging (MRI) | August 01, 2019 | Jeff Zagoudis, Associate Editor
The U.S. Food and Drug Administration (FDA) issued a new draft guidance titled Testing and Labeling Medical Devices for...
360 Photos | Magnetic Resonance Imaging (MRI) | May 17, 2019
This is a dedicated cardiac Siemens 1.5T MRI system installed at the...