Technology | December 15, 2014

New Version of Siemens’ Definition Edge Brings Dual Energy to Routine CT Imaging

New TwinBeam Dual Energy for single-source CT enables simultaneous imaging at two different energy levels

dual energy, Siemens, Definition edge, single source dual energy scanning
iMAR, siemens, metal artifact reduction

Reconstruction of a chest CT with iMAR metal artifact reduction filtering to eliminate metal blooming from a bi-ventricular assist device (VAD).


December 15, 2014 — The new version of the Siemens Somatom Definition Edge CT system, which debuted at the Radiological Society of North America (RSNA) 2014 annual meeting, allows dual energy images to be acquired using a single-source system in clinical routine. 
 
The TwinBeam Dual Energy X-ray tube concept of the relaunched Definition Edge enables simultaneous imaging at two different energy levels for the first time in single-source computed tomography (CT).
 
In dual energy imaging, the same region of the body is examined using two different energy levels. The resulting two datasets offer more detailed information about tissue composition that extends beyond pure morphology. However, in cases where data have been acquired using fast kV-switching or dual layer detector technology, dual energy imaging has had significant drawbacks. In the past, single-source dual energy images acquired with these methods were excluded from routine clinical use because the X-ray tube did not emit the two energy spectra simultaneously, but rather in succession through rapid switching or spectral separation at the detector side. With kV-switching, the segmentation of the measuring points impairs image quality significantly due to the limited data per energy level. Also, increased X-ray doses are inevitable because the dose cannot be modulated to reduce radiation.
 
Siemens’ approach to dual energy imaging technology in general offers tissue characterization that could be applicable in clinical situations like the evaluation of kidney stones to differentiate between uric acid and non-uric acid stones, which provides additional diagnostic information. Another example: When examining liver lesions, the material information contained in the dual energy imaging acquisition can indicate liver lesions, with information that is based on the determination of contrast uptake in the tumor (iodine maps).
 
The new version of the Somatom Definition Edge also can simplify the radiology workflow considerably. Unlike other single-source dual energy CT imaging, the Edge’s acquired dual energy datasets are preprocessed intelligently directly after acquisition. 
 
Metal Artifact Reduction
To further improve not only the quality of dual energy examinations but also conventional CT scans using the Definition Edge, Siemens is introducing imam — a new iterative algorithm for metal artifact reduction. With iMAR, metal artifacts can be reduced. Installed Definition Edge and Definition AS+ CT scanners can be retrofitted with TwinBeam technology, iMAR and ADMIRE (in combination with the Stellar detector). iMAR is pending 510(k) clearance and is not yet commercially available in the United States.
 
For more information: www.siemens.com

Related Content

News | Computed Tomography (CT)

April 22, 2024 — A new study showed that a non-invasive imaging test can help identify patients with coronary artery ...

Home April 22, 2024
Home
Feature | Computed Tomography (CT) | By Alberto Morales, MD

Cardiac CT scans, recommended by the American College of Cardiology (ACC) and the American Heart Association (AHA) as ...

Home March 20, 2024
Home
News | Computed Tomography (CT)

February 20, 2024 — Ultrahigh-spatial-resolution photon-counting detector CT improved assessment of coronary artery ...

Home February 20, 2024
Home
News | Computed Tomography (CT)

HeartFlow is offering a free webinar based on a recent study that measured the ability of the of its roadmap analysis to ...

Home January 15, 2024
Home
News | Computed Tomography (CT)

December 19, 2023 — Siemens Healthineers announced the Food and Drug Administration (FDA) clearance of the Somatom Pro ...

Home December 19, 2023
Home
Feature | Computed Tomography (CT) | By Andrew Michalski, PhD and Rohit Sood MD, PhD

Coronary artery disease (CAD), also known as ischemic heart disease, is the most common heart disease with a prevalence ...

Home December 05, 2023
Home
News | Computed Tomography (CT)

October 26, 2023 — HeartFlow, Inc., a leader in non-invasive integrated artificial intelligence (AI) heart care ...

Home October 26, 2023
Home
News | Computed Tomography (CT)

October 13, 2023 — Arineta Cardiac Imaging is excited to announce the FDA 510(k) clearance of the SpotLight and ...

Home October 13, 2023
Home
News | Computed Tomography (CT)

September 29, 2023 —Nano-X Imaging, an innovative medical imaging technology company, today announced that HealthCCSng ...

Home September 29, 2023
Home
News | Computed Tomography (CT)

September 19, 2023 — An advanced CT test can identify individuals with stable angina at a reduced risk of three-year ...

Home September 19, 2023
Home
Subscribe Now