Feature | April 25, 2014

New Heart Assist Pump Allows Minimally Invasive Approach at Vanderbilt Heart and Vascular Institute

heartware lvads vanderbilt heart heartmate

The new HeartWare left ventricular assist device (LVAD) is implanted through a minimally invasive approach and sits inside the chest, connecting directly to the heart.


April 25, 2014 — Vanderbilt Heart and Vascular Institute (VHVI) was the first facility in Tennessee to implant the miniaturized HeartWare HVAD pump through a minimally invasive approach known as a thoracotomy, a small incision on the side of the chest.

The HVAD pump is a miniaturized, full output device designed to be implanted in the pericardial space. It sits inside the chest and connects directly to the heart. No abdominal dissection is required in the implant procedure. The mechanically operated heart pump is meant to bridge heart failure patients to transplantation.

Last year, Simon Maltais, M.D., assistant professor of cardiac surgery and director of the heart transplant and ventricular support program at VHVI, traveled to the University Heart Center in Leipzig, Germany, to observe Martin Strueber, M.D., and Jan Schmitto, M.D., of Hanover, Germany, as they implanted the HeartWare device. They are now considered pioneers of the minimally invasive LVAD (left ventricular assist device) approach.

Over the last year, VHVI became the largest minimally invasive LVAD center in the United States. To date, Maltais has implanted 50 HeartWare devices, 40 percent of them minimally invasively, which requires a small 4-6 cm incision. This approach avoids opening the chest through a sternotomy, thus decreasing operating room (OR) time, risk of perioperative bleeding and infection.

“We try to minimize splitting the sternum, which can be very traumatic. This facilitates the reoperation for the eventual heart transplant. It’s a very big advantage,” Maltais said.

Combined with another LVAD device known as HeartMate II, which VHVI started using in 2008, Vanderbilt performed 82 LVAD procedures in 2013, placing it in the top five medical centers in the country for the number of implants. All told, LVAD survival rates are at 90 percent at Vanderbilt, Maltais said.

The HeartMate II is a high-speed axial flow rotary blood pump. It drains blood continuously from the left ventricle to the aorta by the action of the internal rotor, leading to improved long-term performance.

An article that appeared recently in the New England Journal of Medicine outlined an increased rate of pump thrombosis (blood clots) with the HeartMate II. Vanderbilt, which has a collaborative relationship with the Mayo Clinic and the University of Michigan to study LVAD outcomes, had not observed this trend. Maltais and John Stulak, M.D., of the Mayo Clinic, studied the outcomes from 516 HeartMate II pump implants performed at the three institutions and submitted their results to the NEJM. Their letter, written in response to the original article, appeared in the April 10 issue of the journal.

While the group’s findings confirmed a similar peak in pump thrombosis in 2012, it unanimously observed a decrease in 2013, according to the NEJM letter.

“These observations were found consistent at each individual center before combining data. While the field is indebted to the report by Starling et al, we have observed a different trajectory in confirmed pump thrombosis incidence more recently,” the authors wrote. “While we believe this important information should be available to readers, it reaffirms the need to standardize patient management in this challenging population.”

“This work will be widely cited in the upcoming years and proves our ability to be in the top of advanced heart failure centers in the country. Our advanced heart failure research program is very productive and is part of making the field progress,” Maltais said.

For more information: www.mc.vanderbilt.edu


Related Content

News | Ventricular Assist Devices (VAD)

October 31, 2023 — Tenaya Therapeutics, Inc., a clinical-stage biotechnology company with a mission to discover, develop ...

Home October 31, 2023
Home
News | Ventricular Assist Devices (VAD)

June 7, 2023 — Magenta Medical Ltd. has announced the initiation of its FDA-approved Early Feasibility Study with the ...

Home June 07, 2023
Home
News | Ventricular Assist Devices (VAD)

March 1, 2023 — Mesoblast Limited, global leader in allogeneic cellular medicines for inflammatory diseases, today ...

Home March 01, 2023
Home
News | Ventricular Assist Devices (VAD)

November 2, 2022 — For decades, left ventricular-assist devices (LVADs) have extended the lives of people whose hearts ...

Home November 02, 2022
Home
News | Ventricular Assist Devices (VAD)

October 18, 2022 — The U.S. Food and Drug Administration (FDA) is providing updates to the FDA website to include ...

Home October 18, 2022
Home
News | Ventricular Assist Devices (VAD)

August 25, 2022 — The U.S. Food and Drug Administration (FDA) issued a statement that Medtronic, Inc. is recalling ...

Home August 25, 2022
Home
News | Ventricular Assist Devices (VAD)

August 5, 2022 — Black people and women with severe heart failure who might be good candidates for surgery to implant a ...

Home August 05, 2022
Home
News | Ventricular Assist Devices (VAD)

June 23, 2022 — Medtronic, Inc. is recalling a single lot of HeartWare HVAD System batteries due to welding defects that ...

Home June 23, 2022
Home
News | Ventricular Assist Devices (VAD)

June 8, 2022 — The U.S. Food and Drug Administration (FDA) has issued a release stating that Medtronic is recalling the ...

Home June 08, 2022
Home
News | Ventricular Assist Devices (VAD)

April 28, 2022 — The U.S. Food and Drug Administration (FDA) is alerting healthcare providers to the possibility that ...

Home April 28, 2022
Home