News | Magnetic Resonance Imaging (MRI) | May 24, 2016

New Cardiac MRI Technique Removes Patients' Need to Breathe

Lack of motion allows acquisition of higher quality images in less time

cardiac magnetic resonance, CMR, breathing, high frequency percussive ventilation, EuroCMR 2016

May 24, 2016 — A new technique for cardiac magnetic resonance (CMR) imaging improves accuracy by removing patients' need to breathe, reveals research presented at EuroCMR 2016. Data was presented by Prof. Juerg Schwitter, director of the Cardiac MR Centre at the University Hospital Lausanne, Switzerland. The lack of motion allows acquisition of higher quality images in less time.

"In many imaging techniques, but particularly in CMR, you need a relatively long acquisition time and must correct for respiratory motion," said Schwitter. "For decades we have had to correct for respiration when estimating the position and motion of the heart by CMR, and this is not always accurate."

He continued: "In Lausanne, radio-oncologists are exploring a technique called high frequency percussive ventilation. Patients do not need to breathe naturally and no correction for respiratory motion is required. This enables the physicians to more accurately plan the field of radiation to apply in each patient."

For the technique, patients put a mask over their mouth which is connected to a ventilator that delivers small volumes of air, called "percussions." Instead of the 10 to 15 large breaths patients would take naturally per minute, air is provided in 300 to 500 small ventilations per minute. Air volumes are small so the chest does not move. The procedure is noninvasive, patients are conscious, not sedated, and do not need to breathe.

For the current study, the ventilator was adapted for use in the CMR environment. CMR uses a magnet, which means that metal parts had to be swapped for MR-compatible ones. Tubes were used to connect equipment inside and outside the scanning room.

Schwitter said, "Patients lie face up in the CMR machine and do not need to breathe. They say their chest feels a bit inflated during the ventilation but otherwise it feels okay."

The study was designed to test the feasibility and tolerability of high frequency percussive ventilation during CMR. It included one healthy volunteer aged 38 years and one patient aged 55 years with a thymic lesion. The procedure was well tolerated in both cases. The average time without breathing was 10 minutes in the volunteer and six minutes in the patient.

The investigators could clearly see the coronary arteries. Lung volumes were "frozen" in full inspiration and the pulmonary vessels were also seen clearly. There was no need to correct for respiratory motion.

Schwitter said, "We found that this type of ventilation was feasible and there was no problem with tolerating it. Of course, we are in a very early stage of development and we now need to test it in more patients. Some patients may find it difficult because the CMR machine is small and on top of that they will be ventilated by a machine."

CMR images are currently acquired in steps. Patients breathe in and then hold their breath for each image, then recover before repeating the process for the next image. High frequency percussive ventilation offers the potential to acquire all images in one go, with no need to correct for respiratory motion.

"The possibilities with high frequency percussive ventilation are huge," said Schwitter. "You could run all the CMR sequences in one batch, which would be much faster. Data could be acquired constantly with fewer artifacts. We might be able to use this technique for diagnosis of sicker patients, who find breath holding difficult and need the imaging to be done quickly."

He continued, "This technique would help us to collect high resolution images where we want millimetric precision, for example to localize scar in the myocardium or to see the anatomy of coronary arteries or valves and malformations. We would have much better conditions because we would not need to correct for motion."

Schwitter concluded, "We have made promising first steps with high frequency percussive ventilation in CMR. In future we could even imagine that if the patient is not breathing for 20 minutes or even longer this technique could give a precise 3-D representation of cardiac structures and help guide electrophysiology procedures such as ablation."

For more information: www.escardio.org

Related Content

ASNC and SNMMI Release Joint Document on Diagnosis, Treatment of Cardiac Sarcoidosis
News | Cardiac Imaging| August 18, 2017
August 18, 2017 — The American Society of...
Houston Methodist Hospital Enters Multi-Year Technology and Research Agreement With Siemens Healthineers
News | Cardiac Imaging| August 17, 2017
Houston Methodist Hospital and Siemens Healthineers have entered into a multi-year agreement to bring cutting-edge...
ISMRM Issues Guidelines for MRI Gadolinium Contrast Agents
News | Magnetic Resonance Imaging (MRI)| August 15, 2017
The International Society for Magnetic Resonance in Medicine (ISMRM) has provided new guidance in the use of contrast...
CDN to Integrate Advanced Cardiac Imaging Tools From DiA Imaging Analysis
Technology | August 10, 2017
August 10, 2017 — CDN recently announced a new partnership agreement with DiA Imaging Analysis Ltd., makers of next-g
Four Blue Cross Blue Shield Companies Issue Positive Medical Policies on HeartFlow FFRct Analysis
News | FFR Catheters| August 09, 2017
HeartFlow Inc. announced that four Blue Cross Blue Shield companies have each issued a positive medical policy for the...
GE Healthcare's Signa Premier MRI Receives FDA 510(k) Clearance
Technology | Magnetic Resonance Imaging (MRI)| August 04, 2017
GE Healthcare announced Signa Premier, a new wide bore 3.0T magnetic resonance imaging (MRI) system, is now available...
Left Atrial Pressure Monitor from Vectorious Medical Technologies Offers New Hope for Heart Failure Patients

On of the top stories in July was the introduction of a left atrial pressure monitor from Vectorious Medical Technologies to prevent heart failure patient hospitalizations or readmissions. Read the article"Left Atrial Pressure Monitor Offers New Hope for Heart Failure Patients."

Feature | August 01, 2017 | Dave Fornell
Aug.
Philips released a new version of its iFR system that displays FFR readings as an overlay on live angiographic, angiogram images.

Philips released a new version of its iFR system that displays hemodynamic pressure drop points in an overlay on live angiographic images, matching up the iFR readings with corresponding lesions. The system is supposed to speed diagnostic decision making and help guide percutaneous revascularization procedures. 

Feature | FFR Catheters| July 31, 2017 | Dave Fornell
The gold standard for assessing the hemodynamic significance of coronary lesions to determine if they should be revas
New PET-CT Scan Improves Detection in Rare Cardiac Condition
News | PET-CT| July 25, 2017
Using a new imaging technique that can diagnose cardiac sarcoidosis much more accurately than traditional tests,...
Overlay Init