News | Magnetic Resonance Imaging (MRI) | March 28, 2016

New Class of Molecular Lightbulbs Illuminate MRI

Duke researchers synthesize molecular tags that generate significantly stronger signal for longer to track biochemical reactions

Duke University study, molecular lightbulbs, MRI imaging agent

Duke scientists have discovered a new class of inexpensive and long-lived molecular tags that enhance MRI signals by 10,000-fold. To activate the tags, the researchers mix them with a newly developed catalyst (center) and a special form of hydrogen (gray), converting them into long-lived magnetic resonance 'lightbulbs' that might be used to track disease metabolism in real time. Image courtesy of Thomas Theis, Duke University.

March 28, 2016 — Duke University researchers have taken a major step towards realizing a new form of magnetic resonance imaging (MRI) that could record biochemical reactions in the body as they happen.

In the March 25 issue of Science Advances, they report the discovery of a new class of molecular tags that enhance MRI signals by 10,000-fold and generate detectable signals that last over an hour. The tags are biocompatible and inexpensive to produce, paving the way for widespread use of MRI to monitor metabolic processes of conditions like cancer and heart disease in real time.

“This represents a completely new class of molecules that doesn’t look anything at all like what people thought could be made into MRI tags,” said Warren S. Warren, James B. Duke Professor and Chair of Physics at Duke, and senior author on the study. “We envision it could provide a whole new way to use MRI to learn about the biochemistry of disease.”

MRI takes advantage of a property called spin, which makes the nuclei in hydrogen atoms act like tiny magnets. Applying a strong magnetic field, followed by a series of radio waves, induces these hydrogen magnets to broadcast their locations. Since most of the hydrogen atoms in the body are bound up in water, the technique is used in clinical settings to create detailed images of soft tissues like organs, blood vessels and tumors inside the body.

But the technique also has the potential to show body chemistry in action, said Thomas Theis, assistant research professor of chemistry at Duke and co-lead author on the paper. “With magnetic resonance in general, you have this unique sensitivity to chemical transformations. You can see them and track them in real time,” Theis said.

MRI’s ability to track chemical transformations in the body has been limited by the low sensitivity of the technique, which makes small numbers of molecules impossible to detect without using unattainably massive magnetic fields.

For the past decade, researchers have been developing methods to “hyperpolarize” biologically important molecules, converting them into what Warren calls magnetic resonance “lightbulbs.”

With this boosted signal, these “lightbulbs” can be detected even in low numbers. “Hyperpolarization gives them 10,000 times more signal than they would normally have if they had just been magnetized in an ordinary magnetic field,” Warren said.

While promising, Warren says these hyperpolarization techniques face two fundamental problems: incredibly expensive equipment — around $3 million for one machine — and most of these molecular lightbulbs burn out in a matter of seconds.

“It’s hard to take an image with an agent that is only visible for seconds, and there are a lot of biological processes you could never hope to see,” said Warren. “We wanted to try to figure out what molecules could give extremely long-lived signals so that you could look at slower processes.”

Jerry Ortiz Jr., a graduate student at Duke and co-lead author on the paper, synthesized a series of molecules containing diazarines, a chemical structure which is composed of two nitrogen atoms bound together in a ring. Diazirines were a promising target for screening because their geometry traps hyperpolarization in a “hidden state” where it cannot relax quickly.

Using a simple and inexpensive approach to hyperpolarization called SABRE-SHEATH, in which the molecular tags are mixed with a spin-polarized form of hydrogen and a catalyst, the researchers were able to rapidly hyperpolarize one of the diazirine-containing molecules, greatly enhancing its magnetic resonance signals for over an hour.

Qiu Wang, assistant professor of chemistry at Duke and co-author on the paper, said this structure is a particularly exciting target for hyperpolarization because it has already been demonstrated as a tag for other types of biomedical imaging.

“It can be tagged on small molecules, macromolecules, amino acids, without changing the intrinsic properties of the original compound,” said Wang. “We are really interested to see if it would be possible to use it as a general imaging tag.”

The scientists believe their SABRE-SHEATH catalyst could be used to hyperpolarize a wide variety of chemical structures at a fraction of the cost of other methods.

“You could envision, in five or ten years, you’ve got the container with the catalyst, you’ve got the bulb with the hydrogen gas. In a minute, you’ve made the hyperpolarized agent, and on the fly you could actually take an image,” Warren said. “That is something that is simply inconceivable by any other method.”

Other authors include Angus W. J. Logan, Kevin E. Claytor, Yesu Fang, William P. Huhn, Volker Blum and Steven J. Malcolmson of Duke University and Eduard Y. Chekmenev of Vanderbilt University.

This research was supported by the National Science Foundation (CHE-1058727, CHE-1363008, CHE-1416268), the National Institutes of Health (1R21EB018014), the Department of Defense Congressionally Directed Medical Research Programs Breast Cancer grant (W81XWH-12-1-0159/BC112431), the Pratt School of Engineering Research Innovation Seed Fund, the Burroughs Wellcome Fellowship and the Donors of the American Chemical Society Petroleum Research Fund.

For more information:

Related Content

Ligand Establishes Program to Develop Captisol-Enabled, Next-Generation Diagnostic Imaging Contrast Agents
News | Contrast Media | January 19, 2018
Ligand Pharmaceuticals Inc. announced initiation of a program to develop contrast agents with reduced renal toxicity....
FDA Holds MIDAC Meeting on Gadolinium-Based Contrast Agents. Image by Marilyn Fornell
News | Contrast Media | September 07, 2017
The U.S. Food and Drug Administration (FDA) announced it would hold a meeting of the Medical Imaging Drugs Advisory...
European Medicines Agency Issues Update on Gadolinium Contrast Agents
News | Contrast Media | August 29, 2017
August 29, 2017 — The European Medicines Agency (EMA) issued a final opinion that recommended restricting the use of
Guerbet Announces Plans to Streamline Contrast Media Portfolio, gadolinium MRI contrast
News | Contrast Media | July 18, 2017
Guerbet recently announced that it will phase out sales throughout the world of two products: Hexabrix (meglumine and...
ACR Offers Revised Contrast Media in Imaging Manual
News | Contrast Media | July 17, 2017
The American College of Radiology (ACR) recently revised its authoritative guide for the safe and effective use of...
Bayer Arterion contrast Injector used to administer medical imaging contrast for CT scans.

Bayer Healthcare's Arterion contrast injector system.

Feature | Contrast Media | June 19, 2017 | Dave Fornell
Here are several updates in medical imaging...
PRAC, European Medicines Agency, gadolinium-based contrast agents, safety recommendations, brain MRI
News | Contrast Media | March 13, 2017
The Pharmacovigilance Risk Assessment Committee (PRAC) of the European Medicines Agency recently released new...
Lantheus Medical Imaging, Definity, FDA approval, label update, echocardiography, cardiac shunt contraindication
Technology | Contrast Media | February 02, 2017
Lantheus Medical Imaging Inc. announced U.S. Food and Drug Administration (FDA) approval of a label update for Definity...
CT, computed tomography, IV contrast media, acute kidney injury risk, Annals of Emergency Medicine study

A new study in Annals of Emergency Medicine finds no association between intravenous contrast media used in computed tomography (CT) and kidney damage. Roughly 80 million doses of IV contrast media are given every year. Credit: American College of Emergency Physicians

News | Contrast Media | January 30, 2017
Intravenous contrast media (typically iohexol or iodixanol) used in computed tomography (CT) does not appear to be...
GE Healthcare, Optison ultrasound contrast agent, FDA labeling change, cardiac shunts, intra-arterial injection
Technology | Contrast Media | October 04, 2016
GE Healthcare announced that the U.S. Food and Drug Administration (FDA) has approved a label change for the ultrasound...