News | August 24, 2008

No Difference Seen with DES vs. Bare Metal Stents for Narrowing in Saphenous Vein Grafts

August 25, 2008 - A study conducted by the Cardiovascular Research Institute, Washington Hospital Center, Washington, D.C. indicates both drug-eluting stents (DES) and bare metal stents (BMS) for catheter-based treatment of saphenous vein graft (SVG) stenoses provide acceptably safe and efficacious results, but unlike the case in native coronary arteries, DES use does not reduce the frequency of the need for repeat revascularization.

The study is published in the Sept. 1 issue of the American Journal of Cardiology.

Researchers said there is conflicting data regarding an advantage of DES over BMS, in SVG, so the study was undertaken to compare the efficacy of these modalities in that lesion subset. The DES group consisted of 138 cases with 183 lesions (sirolimus-eluting stents, n = 117; paclitaxel-eluting stents, n = 66) and the BMS group consisted of 344 cases with 478 lesions that were followed to one year.

At one year researchers said there was no significant superiority of DES over BMS with regard to hard end points (death and Q-wave myocardial infarction).

For more information: www.ajconline.org

Related Content

The Biotronik Osiro is an ultra thin strut, sirolimus-eluting stent. #TCT2018

The Biotronik Osiro is an ultra thin strut, sirolimus-eluting stent.

News | Stents | October 04, 2018
October 4, 2018 – Investigators unveiled clinical data from the independent BIONYX and SORT OUT IX all-comers trials
FDA Approves Biotronik's PK Papyrus Stent for Coronary Perforations
Technology | Stents | September 27, 2018
September 27, 2018 — Biotronik recently announced U.S.
Videos | Stents | September 11, 2018
This is an animation showing how the dedicated bifurcation stent developed by Advanced Bifurcation Systems (ABS) is d
Elixir Medical Corporation Unveils Transformational DynamX Stent Featuring Adaptive Segments that Uncage the Stented Artery
News | Stents | January 25, 2018
January 25, 2018 – Elixir Medical Corporation, a leader in the development of breakthrough adaptive remodeling techno
The TIDES-ACS results show us that the Optimax stent is noninferior in patients with acute coronary syndrome compared to Synergy.

The presentation of the ESC late-breaker TIDES-ACS results show us that the Optimax stent is noninferior in patients with acute coronary syndrome compared to Synergy.

News | Stents | November 24, 2017
November 24, 2017 – During a late-breaking session at the European Society of Cardiology (ESC) 2017 meeting, presente
News | Stents | November 10, 2017
Cordis, a Cardinal Health company, recently unveiled a comprehensive interventional cardiology portfolio, which now...
OCT comparison between the Combo vs. Xience stents in the HARMONEE study.

OCT comparison between the Combo vs. Xience stents in the HARMONEE study.

Feature | Stents | November 08, 2017
November 8, 2017 – New results from the HARMONEE Japan/U.S.
FDA Approves COBRA REDUCE Trial of 14-Day DAPT With CeloNova Stent
News | Stents | October 27, 2017
CeloNova BioSciences Inc. announced the U.S. Food and Drug Administration (FDA) approved expansion of CeloNova's...
CeloNova Cobra Pzf stent
Technology | Stents | March 02, 2017
March 2, 2017 — The U.S. Food and Drug Administration (FDA) cleared CeloNova BioSciences Inc.
OCT, intravascular imaging, stent, good stent apposition on vessel wall, TRANSFORM-OCT study

An OCT image showing good stent strut apposition against the vessel wall.

News | Stents | January 13, 2017
January 13, 2017 — Results from TRANSFORM-OCT, a prospective, randomized trial using optical coherence tomography (OC
Overlay Init