Study Evaluates Semi-Automated Quantification of Right Ventricular Size and Function

EchoInsight software found to be accurate and efficient compared to conventional methods

EchoInsight, right ventricle, quantitative assessment, RV, study

May 22, 2015 — A study in the May issue of the International Journal of Cardiovascular Imaging examines the ability of the EchoInsight software to achieve quantitative assessment of the right ventricle (RV). The study, “Semi-automated Echocardiographic Quantification of Right Ventricular Size and Function," was published by Diego Medvedofsky, Karima Addetia, Roberto Lang, Victor Mor-Avi, et al.

An excerpt from the study reads:

"Until recently, RV assessment was qualitative only and thus subjective and experience dependent. The new guidelines from the ASE [American Society of Echocardiography] have emphasized the importance of quantitative assessment of RV size and function and encouraged making these measurements standard in clinical practice. Previous studies have shown that RV measurements provide important prognostic and therapeutic information in patients with heart disease. However, current quantitative approaches rely on manual measurements performed on a variety of images, including endocardial boundary tracings on 2-D images for chamber area and dimensions, measurements of TAPSE on M-Mode images and S' on tissue Doppler images. This methodology is time-consuming and experience dependent. As a result, in clinical practice, visual qualitative assessment of RV size and function is usually used instead, despite the clear benefits of a quantitative assessment. Accordingly, development of new tools for fast, accurate and reproducible measurement of RV indexes would address an important clinical need."

This study compared manual versus semi-automated (EchoInsight) approaches in transthoracic echo images obtained in 149 patients with a wide range of RV size and function; all images were analyzed by an expert. Both techniques were used to obtain fractional area change (FAC), linear chamber dimensions, tricuspid annular plane systolic excursion (TAPSE) and S'. Fifteen patients were excluded due to image quality (90 percent feasibility). Time required with EchoInsight was approximately 30 seconds per patient, compared to 4 minutes for conventional analysis. The parameters obtained with EchoInsight were in agreement with manual measurements: r-values 0.79–0.95 for RV size and 0.70–0.74 for function indices and biases of 2–22 percent of the mean measured values, which were comparable to the intrinsic variability of the conventional technique.

The study concluded EchoInsight is feasible, fast and provides quantitative parameters of RV size and function, which are comparable to conventional measurements. 

For more information: www.epsilon-imaging.com

Related Content

Toshiba Medical Rolls Out Interactive Learning Tools for Ultrasound and Vascular Training
News | Ultrasound Imaging | December 04, 2017
Toshiba Medical, a Canon Group company, introduced new educational tools and interactive learning resources to help...
Toshiba Medical's Portable Ultrasound Used in Second Pediatric Mission in Tanzania
News | Ultrasound Imaging | October 05, 2017
October 5, 2017 — To provide lifesaving surgical care for sick children in one of the most underserved countries, 13
Clarius Wireless Ultrasound Scanners Now Available With Advanced Features
News | Ultrasound Imaging | August 09, 2017
Clarius Mobile Health has released advanced features and options for its wireless handheld ultrasound scanner for...
Oregon Tech Partners with Mindray for High-Tech Ultrasound Education
News | Ultrasound Imaging | August 04, 2017
To better prepare its ultrasound students to compete and thrive in the evolving healthcare environment, Oregon...
News | Ultrasound Imaging | March 28, 2017
Young rabbits exposed to ultrasound during fetal development had weaker thighbones than unexposed rabbits, according to...
ultrasound systems market, $5 billion, 2023, GlobalData report
News | Ultrasound Imaging | January 25, 2017
The ultrasound systems space, which covers 39 major markets, is set to rise steadily from $4.2 billion in 2016 to $5...
GE Healthcare, Vscan Extend, app-based ultrasound, dual-probe, RSNA 2017
Technology | Ultrasound Imaging | January 12, 2017
GE Healthcare unveiled its new generation of pocket-sized, dual-probe ultrasound, the Vscan Extend. From the hospital...
Toshiba, Aplio 500 Platinum ultrasound, International Contrast Ultrasound Society, ICUS, live case, contrast-enhanced ultrasound
News | Ultrasound Imaging | September 07, 2016
September 7, 2016 — Toshiba America Medical Systems Inc.
best ultrasound technician schools, 2016 ranking, College Choice
News | Ultrasound Imaging | August 22, 2016
August 22, 2016 — College Choice, a leading authority in college and university rankings and resources, has published
ContextVision, US PLUSView ultrasound enhancement software, iOS
Technology | Ultrasound Imaging | July 11, 2016
ContextVision has signed a contract to bring its US PLUSView ultrasound image enhancement software to hand-held iOS-...
Overlay Init