Cardiac Resychronization Therapy Fails for Certain Heart Failure Patients

The EchoCRT trial was ended early to prevent harm to patients

September 5, 2013 — Researchers announced this week that an attempt to expand cardiac resynchronization therapy (CRT) to include more patients with heart failure has failed and an international clinical trial ended early to prevent potential harm to patients. 
 
The Echocardiography Guided Cardiac Resynchronization Therapy (EchoCRT) is the largest international, multicentre, prospective, randomized, double-blind, clinical trial of its kind. Results of the trial are available online by the New England Journal of Medicine and were presented during this week’s Late Breaking Clinical Trials session at the European Society of Cardiology Congress in Amsterdam, Netherlands.
 
The trial found the widespread off-label use of CRT in patients with narrow QRS should no longer be used as an option for patients with a QRS below 130 milliseconds, regardless of mechanical dyssynchrony. This trial serves as a reminder that in clinical medicine adequately powered definitive clinical outcome trials are needed before we expand the use of an apparently favorable therapy.
 
“Cardiac resynchronization therapy is a proven treatment for people who have a type of heart failure that includes an electrical abnormality, or a wide QRS complex,” said William Abraham, M.D., director of the division of cardiovascular medicine at The Ohio State University Wexner Medical Center and national co-principal investigator of the study. “We noticed some cardiologists were also trying CRT in heart failure patients who did not have this electrical abnormality, however no large studies had tested the use of CRT in this way.”
 
In 2008, cardiovascular researchers at 115 centers in Europe, Australia and the United States teamed up to test the safety and efficacy of CRT in heart failure patients who had a narrow QRS complex. Patients were enrolled in the study if they had an ejection fraction of 35 percent or less, a narrow QRS duration of 130 milliseconds or less and echocardiographic evidence of a left ventricular dyssynchrony. A total of 809 study participants underwent implantation of a cardiac resynchronization device with defibrillator capability developed by Biotronik. Half (404) were randomized to have CRT turned on while the other half (405) did not receive CRT. All study participants had the defibrillator capability turned on.
 
After following each participant an average of 19 months, the trial was stopped in March on the basis of futility and potential for harm. Researchers recorded 45 deaths and 224 hospitalizations for worsening heart failure in the CRT group compared to 26 deaths and 194 hospitalizations in the control group. 
 
“Not only did cardiac resynchronization not help these patients with systolic heart failure, but the data showed the potential for harm,” said Abraham. “This is a landmark trial in CRT and heart failure because it tells us we should not use this therapy in this group of patients.”
 
Heart failure occurs when the heart does not pump blood efficiently, most often due to a weak heart muscle. Patients suffer from shortness of breath, fatigue, swelling and reduced quality of life. According to the American Heart Association, about 5.7 million Americans have heart failure and it accounts for about 1 million hospital admissions each year at an estimated societal cost of $32 billion.
 
“We’re always looking for better treatments for patients with heart failure to improve their quality of life and reduce their hospitalizations,” said  Ayesha Hasan, M.D., a heart failure cardiologist at Ohio State’s Richard M. Ross Heart Hospital and the lead principal investigator at Ohio State. “We now know expanding the use of CRT in this population of patients is not a positive solution.”
 
Abraham says researchers are still investigating why CRT did not work for this group of patients, to better understand the benefits and challenges of this treatment option.
 
“The EchoCRT trial evaluated an important question for daily clinical practice.  The results will help to guide physicians’ treatment decisions for heart failure patients moving forwards.” said co-lead investigator Johannes Holzmeister, M.D., from University Hospital in Zurich, Switzerland.
Biotronik funded the FDA-approved trial. Abraham is a paid consultant for the company.
 
For more information: bit.ly/1buTeHk
 

Related Content

common adult CT examinations, computed tomography, diagnostic reference levels, DRLs, radiation dose, achievable dose, AD
News | Radiation Dose Management| February 23, 2017
Using data from the world’s largest computed tomography (CT) dose index registry, researchers have established national...
News | Cardiac Diagnostics| February 17, 2017
Levels of a protein in the blood associated with heart disease are also linked to early-stage brain damage, according...
Medtronic, expanded indication, Freezor Xtra Cryoablation Catheter, AVNRT, atrioventricular nodal re-entrant tachycardia
Technology | Ablation Systems| February 16, 2017
Medtronic plc announced the U.S. Food and Drug Administration (FDA) has approved its Freezor Xtra Cryoablation Catheter...
Mercator MedSystems, DANCE trial data, ISET, LINC, Bullfrog Micro-Infusion Device
News | Peripheral Arterial Disease (PAD)| February 15, 2017
Mercator MedSystems announced that the national co-principal investigators of the company’s DANCE trial each presented...
Biotronik, ProMRI Configurator tool, MR-conditional cardiac devices, ProMRI SystemCheck
Technology | Implantable Cardiac Monitor (ICM)| February 14, 2017
Biotronik has developed an online tool that streamlines the workflow for physicians selecting the right magnetic...
News | Hypertension| February 13, 2017
Vascular Dynamics Inc. (VDI) announced that the U.S. Food and Drug Administration (FDA) has approved the company’s...
Xarelto, rivaroxaban, COMPASS study, ends early,
News | Antiplatelet and Anticoagulation Therapies| February 09, 2017
February 9, 2017 — Janssen Research & Development LLC (Janssen) announced that the Phase 3 COMPASS trial is stopp
Medtronic, IDE approval, IN.PACT Admiral drug-coated balloon, DCB, end-stage renal disease
News | Drug-Eluting Balloons| February 08, 2017
Medtronic plc announced receipt of an investigational device exemption (IDE) from the U.S. Food and Drug Administration...
CSI, LIBERTY 360 Study, ISET 2017, six-month data, lower extremity PAD
News | Atherectomy Devices| February 08, 2017
February 8, 2017 — Cardiovascular Systems (CSI) presented six-month data from its LIBERTY 360° post-market study in a
Penn Medicine, heart failure causes, YAP and TAZ proteins, Journal of Clinical Investigation study
News | Heart Failure| February 07, 2017
February 7, 2017 — Of the more than 700,000 Americans who suffer a heart attack each year, about a quarter go on to d
Overlay Init