News | Heart Valve Technology | December 19, 2016

First U.S. TAVR Patients Treated With Temporary Pacing Lead

Novel technology designed to reduce complications, shorten length of ICU stays

BioTrace Medical, Tempo Temporary Pacing Lead, TAVR

December 19, 2016 — BioTrace Medical Inc. announced the first commercial use of the company’s Tempo Temporary Pacing Lead since U.S. Food and Drug Administration (FDA) 510(k) clearance in October.

The first cases involved patients undergoing transcatheter aortic valve replacement (TAVR) procedures and were performed by James Harkness, M.D., interventional cardiologist, and Brian K. Whisenant, M.D., medical director of the Structural Heart Disease Program at Intermountain Medical Center in Salt Lake City, Utah, and Susheel Kodali, M.D., director of the Heart Valve Program at Columbia University Medical Center/New York Presbyterian Hospital.

BioTrace Medical’s Tempo Lead is for use in procedures in which temporary pacing is indicated, including TAVR and electrophysiology (EP) procedures. The lead is designed for secure and stable cardiac pacing with the goal of reducing complications and allowing patients to ambulate sooner after procedures.

“I am pleased to now have an innovative new option for temporary pacing for my patients,” said Whisenant. “The lead reliably allows stable and secure placement, and is easy to use. The Tempo Lead is the new standard of care for patients who need temporary pacemaker support.”

“BioTrace’s temporary pacing leads are an exciting advance over existing technologies, which can cause complications that result in poor clinical outcomes and longer hospital stays,” said Martin B. Leon, M.D., director of the Center for Interventional Vascular Therapy at Columbia University Medical Center/New York Presbyterian Hospital, and a member of BioTrace Medical’s Scientific Advisory Board. “The Tempo Lead is designed to alleviate the risks associated with lead dislodgement and inconsistent pacing, providing a safer option for patients.”

Temporary leads are used in more than 350,000 procedures each year, a number that is growing rapidly as the population ages and TAVR becomes increasingly common. The temporary pacing lead, a small catheter with two electrodes, is placed in the right ventricle of the heart through a vein in the groin or neck. The lead is then connected to an external pacemaker allowing a physician to monitor and control a patient’s heart rate for several days.

The Tempo Lead features a novel active fixation mechanism, bipolar electrodes and a soft tip.

Read the article “First U.S. TAVR Patients Treated With Temporary Pacing Lead.”

 

Safety and efficacy results of the first-in-human study of the Tempo Lead were presented in October at the annual Transcatheter Cardiovascular Therapeutics (TCT) conference in Washington, D.C. The multi-center study clearly demonstrated the safety of the Tempo Lead, with no device-related adverse events, dislodgements, sustained ventricular arrhythmia, or cardiac perforations. The device was successfully positioned in 23 patients (92 percent), with two patients having unsuitable anatomy. Pacing with the Tempo Lead was successful in all treated patients with no loss of pace capture or lead dislodgement of the device from within the heart.

The design of conventional temporary pacing leads can cause serious complications. Current temporary leads can be easily dislodged from the heart, which may result in loss of pacing, with serious consequences for the patient. As a result, patients are often limited to bed rest for the duration of temporary pacing lead placement, delaying ambulation and thereby increasing length of stay in costly hospital units such as intensive care. In addition, current leads risk perforation of the heart wall, which may lead to pericardial effusion and tamponade, in which blood from within the heart escapes into the sac surrounding the heart, leading to potentially life-threatening cardiac compression.

BioTrace Medical, Inc., a venture backed company based in San Carlos, Calif., is dedicated to reinventing temporary pacing to improve patient outcomes and reduce hospital costs. 

For more information: www.biotracemedical.com

Related Content

Philips Healthcare, Volcano IVUS showing an implanted stent. IVUS might offer an alternative to contrast angiography in patients with acute kidney disease (AKD).
News | Cath Lab | June 14, 2019
June 14, 2019 – A late-breaking study examined the effects of intravascular ultrasound (IVUS) guided drug-eluting ste
Videos | Cath Lab | May 20, 2019
This is a walk through of the primary structural heart hybrid cath lab at...
Mobility May Predict Elderly Heart Attack Survivors' Repeat Hospital Stays
News | Cath Lab | April 23, 2019
Determining which elderly heart attack patients take longer to stand from a seated position and walk across a room may...
FDA Releases New Guidance on Medical Devices Containing Nitinol
News | Cath Lab | April 18, 2019
April 18, 2019 — The U.S.
Angiography shows a stenotic lesion in the mid right coronary artery, undilatable by standard high-pressure balloon angioplasty (inset, arrowheads). (B) Optical coherence tomography (OCT) cross-sectional (top) and longitudinal (bottom) images acquired before IVL and coregistered to the OCT lens (arrow in A) demonstrate severe near-circumferential calcification in the area of the stenosis. (C) Angiography demonstrates improvement in the area of stenosis after IVL lithoplasty.

Figure 2: Angiography demonstrates a stenotic lesion in the mid right coronary artery, undilatable by standard high-pressure balloon angioplasty (inset, arrowheads). (B) Optical coherence tomography (OCT) cross-sectional (top) and longitudinal (bottom) images acquired before IVL and coregistered to the OCT lens (arrow in A) demonstrate severe near-circumferential calcification (double-headed arrow) in the area of the stenosis. (C) Angiography demonstrates improvement in the area of stenosis after IVL (inset; note the cavitation bubbles generated by IVL [black arrows]). (D) OCT cross-sectional (top) and longitudinal (bottom) images acquired post-IVL and coregistered to the OCT lens (white arrow in C) demonstrate multiple calcium fractures and large acute luminal gain. (E) Angiography demonstrates complete stent expansion with the semicompliant stent balloon (inset) without the need for high-pressure noncompliant balloon inflation. (F) OCT cross-sectional (top) and longitudinal (bottom) images acquired post-stenting and coregistered to the OCT lens (arrow in E) demonstrate further fracture displacement (arrow), with additional increase in the acute area gain (5.17 mm2), resulting in full stent expansion and minimal malapposition.

Feature | Cath Lab | April 15, 2019 | Dean Kereiakes, M.D., FACC, FSCAI, and Jonathan Hill, M.D., DISRUPT CAD III Co-Principal Investigators
Over the last 40 years, despite multiple advancements in percutaneous coronary interventions, calcified lesions remai
BIOTRONIK’s PK Papyrus covered coronary stent. The stent ius used in emergency coronary artery dissections to repair the vessel wall.
Technology | Cath Lab | April 15, 2019
April 15, 2019 — Biotronik began its U.S.
Providing Follow-Up Care After Heart Attack Helps Reduce Readmissions, Deaths
News | Cath Lab | April 09, 2019
A program designed to help heart attack patients with the transition from hospital to outpatient care can reduce...
TherOx Receives FDA Approval for SuperSaturated Oxygen Therapy
Technology | Cath Lab | April 08, 2019
TherOx Inc. announced that the U.S. Food and Drug Administration (FDA) granted premarket approval for its...
Cook Medical Recalls Transseptal Needle Due to Risk of Detached Plastic Fragments
News | Cath Lab | March 20, 2019
March 20, 2019 — Cook Medical is recalling one lot of its...
Overlay Init