News | PET Imaging | July 07, 2017

Novel PET Tracer Detects Small Blood Clots

Fluorine-18 labeled compound offers molecular approach that offers alternative to assessing structural characteristics

Novel PET Tracer Detects Small Blood Clots

PET images (MIP 0-60 min) of three Cynomolgus monkeys. Strong signals are detected at the sites where inserted catheters had roughened surfaces. Almost no other background signal is visible. Only accumulation in the gallbladder becomes visible at the bottom of the image. Credit: Piramal Imaging GmbH, Berlin Germany.


July 7, 2017 — Blood clots in veins and arteries can lead to heart attack, stroke and pulmonary embolism, which are major causes of mortality. In the featured article of The Journal of Nuclear Medicine’s (JNM) July 2017 issue, German researchers show that targeting GPIIb/IIIa receptors, the key receptor involved in platelet clumping, with a fluorine-18 (18F) labeled ligand is a promising approach for diagnostic imaging. Current imaging modalities rely on structural characteristics, such as vascular flow impairment, and do not address the critical molecular components.

“Currently available diagnostic techniques of thrombus [blood clot] imaging rely on different modalities depending on the vascular territory,” explained Andrew W. Stephens, M.D., Ph.D., of Piramal Imaging GmbH, Berlin, Germany. “A single imaging modality that could visualize thrombi from various sources in different anatomic regions would be very valuable.”

For this preclinical study, researchers successfully developed the novel small molecule tracer 18F-GP1 for positron emission tomography (PET) imaging that binds with high affinity to GPIIb/IIIa receptors. 18F-GP1 showed a strong accumulation at the site of thrombus formation, and its binding ability was not affected by anticoagulants such as aspirin and heparin. The tracer showed rapid blood clearance, and PET imaging in a Cynomolgus monkey model demonstrated the detection of small venous and arterial clots, endothelial damage and emboli in the brain.

Due to the favorable pre-clinical results, a first-in-human study of 18F-GP1 is currently underway. Early results from an interim analysis confirm the preclinical data and were presented at the 2017 Annual Meeting of the Society of Nuclear Medicine and Molecular Imaging (SNMMI), June 10-14 in Denver.

“Although the current studies are preliminary, 18F-GP1 may provide not only more accurate anatomic localization, but also information of the risk of the clot growth or embolization,” Stephens pointed out. “This may lead to changes in clinical intervention to the individual patient.” Addressing the use of anticoagulants to treat blood clots, he noted, “These drugs can cause significant and life-threatening bleeding. There is a critical need to balance the risk of bleeding against the risk of clotting in each patient. 18F-GP1 may in the future assist in this important decision.”

For more information: www.jnm.snmjournals.org


Related Content

News | Cardiac Imaging

April 23, 2024 — CDL Nuclear Technologies, a pioneer in advanced diagnostic solutions, is proud to announce the launch ...

Home April 23, 2024
Home
Feature | Cardiac Imaging

Cardiac positron emission tomography (PET) is growing in popularity among cardiologists because it provides the ability ...

Home March 05, 2024
Home
News | Cardiac Imaging

PLEASE NOTE: This webinar has been postponed to a later date. A new date will be posted in the coming days. On March 25 ...

Home February 29, 2024
Home
News | Cardiac Imaging

February 28, 2024 — Royal Philips, a global leader in health technology, announced major enhancements to its Image ...

Home February 28, 2024
Home
News | Cardiac Imaging

February 12, 2024 — According to the American Journal of Roentgenology (AJR), free-breathing cine-deep learning (DL) may ...

Home February 12, 2024
Home
News | Cardiac Imaging

November 16, 2023 — Cardiovascular diseases rank among the top causes of death across the world, and cardiac ...

Home November 16, 2023
Home
News | Cardiac Imaging

September 21, 2023 — Declines in cardiovascular procedure volumes observed early in the COVID-19 pandemic greatly ...

Home September 21, 2023
Home
News | Cardiac Imaging

July 11, 2023 — Hyperfine, Inc., the groundbreaking medical device company that created the Swoop system, the world’s ...

Home July 11, 2023
Home
Feature | Cardiac Imaging | By Matthew Jay Budoff, MD, FACC, FAHA

Coronary computed tomography angiography (CCTA) is cheaper, easier to use and its results are easier to understand than ...

Home July 10, 2023
Home
News | Cardiac Imaging

June 29, 2023 — According to an accepted manuscript published in ARRS’ own American Journal of Roentgenology (AJR) ...

Home June 29, 2023
Home
Subscribe Now