News | May 16, 2017

Novel String-Shaped Subcutaneous ICD Proves Effective in Patients

First-in man study proves feasibility of implanting the first-ever, string-shaped rechargeable device

NewPace ISSD string subcutaneous ICD system

The NewPace string subcutaneous ICD system.

May 16, 2017 – A new study examines the effectiveness of the implantable subcutaneous string defibrillator (ISSD), a flexible, string-shaped and first-ever rechargeable implantable cardioverter-defibrillator (ICD). This is the first-in-man study to report on the feasibility of the innovative device and was presented today at Heart Rhythm 2017, the Heart Rhythm Society’s 38th Annual Scientific Sessions.

Each year, about 300,000 worldwide receive an ICD to protect against irregular heartbeats.[1] In fact, ICDs are proven to be 98 percent effective in treating dangerous ventricular (VT) arrhythmias that can lead to sudden cardiac arrest.[2,3] Although traditional ICDs have been utilized to deliver painless pacing therapy, a subcutaneous ICD does not require leads, but requires an electrically active, metal-encased generator implanted over the ribs.

The new, first-of-its-kind ISSD was designed by NewPace Ltd. in an effort to eliminate the need for an active generator and places only small, flexible device including coils below and over the ribs and totally subcutaneously. The ISSD does not have leads within the heart nor an implantable pulse generator (or can) and provides a minimally invasive approach compared to the Boston Scientific S-ICD, because it only requires two very small incisions with no need to create a pulse generator pocket. This results in minimal anatomical protrusion, for improved patient comfort and aesthetic appearance.

The study enrolled 22 patients ages 69.5 ±8.9 years and 82 percent male with BMI 26.9±3.5 and LVEF 28.9±8.2. The common diagnoses for which the ISSD was used included: non-ischemic cardiomyopathy (18 percent), prior cardiac surgery (14 percent), and primary prevention patients (91 percent). The average implant time was 20 minutes and results include an average defibrillation testing threshold (DFT) of 25.8 joules and a SD of 10.7 joules in successfully screened patients.

“The results are very promising because not only does the subcutaneous string device provide a minimally invasive approach that lowers the risk of infection for patients, but we were also able to successfully implant the device in a short amount of time when compared to other defibrillators,” says lead author, Petr Neužil, M.D., CSc. FESC, chairman at the Department of Cardiology at Na Homolce Hospital in Prague, Czech Republic. “We’re optimistic about this innovative technology and what it means for the future of healthcare. It’s an example of how advancing technology has the potential to improve the quality of life for patients and, ultimately, improve patient outcomes.”

Patients indicated for standard ICD implantation underwent acute subcutaneous insertion of the ISSD device comprised of: a 10 cm long, 5 mm diameter sternal coil, a 10 cm long, 3 mm diameter side coil and a 4 cm long, 1.5 cm diameter cylindrical metal tube called the "active segment". Defibrillation energy from an external defibrillator was delivered through these surfaces so that both the side coil and the active segment were one pole and the sternal coil was the other.

The author notes interest in expanding clinical studies to further test the device for larger patient populations and long-term efficacy.

For more information: www.hrssessions.org, www.HRSonline.org

References:

1. McMaster University. "Common test used on heart patients who need defibrillator implants unnecessary: Study." ScienceDaily. ScienceDaily, 8 May 2014. <www.sciencedaily.com/releases/2014/05/140508172051.htm>
2. Zipes, DP, Roberts, D. for the Pacemaker-Cardioverter-Defibrillator investigators. “Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator: A Comparison of Epicardial and Endocardial Lead Systems.” Circulation. 1995;92:59-65.
3. Volosin et. al. “Virtual ICD: A Model to Evaluate Shock Reduction Strategies.” Heart Rhythm. Vol. 7, N. 5, May supplement 2010. (PO3-125).

Related Content

New Multi-Center Research Effort to Focus on Early Life Origins of Heart Health
News | Congenital Heart| June 23, 2017
Heart health in children will be the focus of three closely synergistic research projects and an integrated...
Feature | EP Lab| June 22, 2017 | Dave Fornell
Electrophysiology (EP) technology has been advancing rapidly the past few years with new ablation tools to improve ar
Pacemakers and Other Cardiac Devices Can Help Solve Forensic Cases
News | Pacemakers| June 20, 2017
Pacemakers and other cardiac devices can help solve forensic cases, according to a study presented at the European...
BioTrace Medical's Tempo Lead Shows Stability and Safety in Real-World Performance
News | Leads Implantable Devices| June 20, 2017
BioTrace Medical Inc. announced that the company’s Tempo Temporary Pacing Lead was featured in an oral presentation and...
BioImage-2 Study to Investigate Atherosclerotic Disease Progression
News | Cardiovascular Ultrasound| June 20, 2017
Mount Sinai Heart and BioImage-2 LLC recently announced the start of the BioImage-2 study investigating the progression...
News | June 12, 2017
June 12, 2017 – Med Alliance announced completion on schedule of patient enrollment in the first-in-man (FIM) study o
Sponsored Content | Videos | Business| June 06, 2017
Andrea Natale, M.D., FACC, FHRS, FESC, executive medical director, Texas Cardiac Arryhthmia Institute at St.
Biosense Webster's multi-electrode RF ablation balloon

The most popular technology in May was the first data released on Biosense Webster's multi-electrode RF ablation balloon with irrigation. The system allows operators to change the energy levels of each electrode to avoid damaging sensitive underlying critical structures like the esophagus or phrenic nerve.

Feature | June 01, 2017 | Dave Fornell
June 1, 2017 — Here is the list of the most popular pieces of content on the Diagnostic and Interventional Cardiology
Infab Introduces Revolution Lead Aprons
Technology | Radiation Dose Management| June 01, 2017
June 1, 2017 — Infab Corp.
Sponsored Content | Videos | Implantable Cardioverter Defibrillators (ICD)| June 01, 2017
Lucas Boersma, M.D., Ph.D., FESC, St.
Overlay Init