News | May 16, 2017

Novel String-Shaped Subcutaneous ICD Proves Effective in Patients

First-in man study proves feasibility of implanting the first-ever, string-shaped rechargeable device

NewPace ISSD string subcutaneous ICD system

May 16, 2017 – A new study examines the effectiveness of the implantable subcutaneous string defibrillator (ISSD), a flexible, string-shaped and first-ever rechargeable implantable cardioverter-defibrillator (ICD). This is the first-in-man study to report on the feasibility of the innovative device and was presented today at Heart Rhythm 2017, the Heart Rhythm Society’s 38th Annual Scientific Sessions.

Each year, about 300,000 worldwide receive an ICD to protect against irregular heartbeats.[1] In fact, ICDs are proven to be 98 percent effective in treating dangerous ventricular (VT) arrhythmias that can lead to sudden cardiac arrest.[2,3] Although traditional ICDs have been utilized to deliver painless pacing therapy, a subcutaneous ICD does not require leads, but requires an electrically active, metal-encased generator implanted over the ribs.

The new, first-of-its-kind ISSD was designed by NewPace Ltd. in an effort to eliminate the need for an active generator and places only small, flexible device including coils below and over the ribs and totally subcutaneously. The ISSD does not have leads within the heart nor an implantable pulse generator (or can) and provides a minimally invasive approach compared to the Boston Scientific S-ICD, because it only requires two very small incisions with no need to create a pulse generator pocket. This results in minimal anatomical protrusion, for improved patient comfort and aesthetic appearance.

The study enrolled 22 patients ages 69.5 ±8.9 years and 82 percent male with BMI 26.9±3.5 and LVEF 28.9±8.2. The common diagnoses for which the ISSD was used included: non-ischemic cardiomyopathy (18 percent), prior cardiac surgery (14 percent), and primary prevention patients (91 percent). The average implant time was 20 minutes and results include an average defibrillation testing threshold (DFT) of 25.8 joules and a SD of 10.7 joules in successfully screened patients.

“The results are very promising because not only does the subcutaneous string device provide a minimally invasive approach that lowers the risk of infection for patients, but we were also able to successfully implant the device in a short amount of time when compared to other defibrillators,” says lead author, Petr Neužil, M.D., CSc. FESC, chairman at the Department of Cardiology at Na Homolce Hospital in Prague, Czech Republic. “We’re optimistic about this innovative technology and what it means for the future of healthcare. It’s an example of how advancing technology has the potential to improve the quality of life for patients and, ultimately, improve patient outcomes.”

Watch a VIDEO interview with Neuzil on the trail at Heart Rhythm 2017.

Patients indicated for standard ICD implantation underwent acute subcutaneous insertion of the ISSD device comprised of: a 10 cm long, 5 mm diameter sternal coil, a 10 cm long, 3 mm diameter side coil and a 4 cm long, 1.5 cm diameter cylindrical metal tube called the "active segment". Defibrillation energy from an external defibrillator was delivered through these surfaces so that both the side coil and the active segment were one pole and the sternal coil was the other.

The author notes interest in expanding clinical studies to further test the device for larger patient populations and long-term efficacy.
 

Read more: heartrhythmjournal.com/article/S1547-5271(17)30589-1/fulltext

For more information: www.hrssessions.org, www.HRSonline.org

References:

1. McMaster University. "Common test used on heart patients who need defibrillator implants unnecessary: Study." ScienceDaily. ScienceDaily, 8 May 2014. <www.sciencedaily.com/releases/2014/05/140508172051.htm>
2. Zipes, DP, Roberts, D. for the Pacemaker-Cardioverter-Defibrillator investigators. “Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator: A Comparison of Epicardial and Endocardial Lead Systems.” Circulation. 1995;92:59-65.
3. Volosin et. al. “Virtual ICD: A Model to Evaluate Shock Reduction Strategies.” Heart Rhythm. Vol. 7, N. 5, May supplement 2010. (PO3-125).

Related Content

News | Cardiovascular Clinical Studies

June 24, 2021 — Data captured in American College of Cardiology (ACC) National Cardiovascular Data Registry (NCDR) ...

Home June 24, 2021
Home
News | Cardiovascular Clinical Studies

January 27, 2021 — A New York Institute of Technology research team has secured a five-year $1.8 million grant from the ...

Home January 27, 2021
Home
News | Cardiovascular Clinical Studies

July 22, 2020 — Eating chocolate at least once a week is linked with a reduced risk of heart disease, according to ...

Home July 22, 2020
Home
News | Cardiovascular Clinical Studies

July 1, 2020 — Carag AG announced receiving U.S. Food and Drug Administration (FDA) Investigational Device Exemption ...

Home July 01, 2020
Home
News | Cardiovascular Clinical Studies

January 20, 2020 — Scientists at Los Alamos and international partners have created the first 3-D images of a special ...

Home January 20, 2020
Home
News | Cardiovascular Clinical Studies

Environmental and lifestyle issues were popular this year, with pick up from both European Society of Cardiology (ESC) ...

Home December 23, 2019
Home
News | Cardiovascular Clinical Studies

November 26, 2019 — The University of Connecticut (UConn) Department of Kinesiology and Hartford Healthcare have ...

Home November 26, 2019
Home
News | Cardiovascular Clinical Studies

July 10, 2019 — The U.S. Food and Drug Administration (FDA) issued the final guidance “Live Case Presentations During ...

Home July 10, 2019
Home
News | Cardiovascular Clinical Studies

July 3, 2019 — The American College of Cardiology (ACC) has partnered with Veradigm, an Allscripts business unit, to ...

Home July 03, 2019
Home
News | Cardiovascular Clinical Studies

November 19, 2018 — The U.S. Food and Drug Administration (FDA) is proposing to add an exception to informed consent ...

Home November 19, 2018
Home
Subscribe Now