Novel String-Shaped Subcutaneous ICD Proves Effective in Patients

First-in man study proves feasibility of implanting the first-ever, string-shaped rechargeable device

NewPace ISSD string subcutaneous ICD system

The NewPace string subcutaneous ICD system.

May 16, 2017 – A new study examines the effectiveness of the implantable subcutaneous string defibrillator (ISSD), a flexible, string-shaped and first-ever rechargeable implantable cardioverter-defibrillator (ICD). This is the first-in-man study to report on the feasibility of the innovative device and was presented today at Heart Rhythm 2017, the Heart Rhythm Society’s 38th Annual Scientific Sessions.

Each year, about 300,000 worldwide receive an ICD to protect against irregular heartbeats.[1] In fact, ICDs are proven to be 98 percent effective in treating dangerous ventricular (VT) arrhythmias that can lead to sudden cardiac arrest.[2,3] Although traditional ICDs have been utilized to deliver painless pacing therapy, a subcutaneous ICD does not require leads, but requires an electrically active, metal-encased generator implanted over the ribs.

The new, first-of-its-kind ISSD was designed by NewPace Ltd. in an effort to eliminate the need for an active generator and places only small, flexible device including coils below and over the ribs and totally subcutaneously. The ISSD does not have leads within the heart nor an implantable pulse generator (or can) and provides a minimally invasive approach compared to the Boston Scientific S-ICD, because it only requires two very small incisions with no need to create a pulse generator pocket. This results in minimal anatomical protrusion, for improved patient comfort and aesthetic appearance.

The study enrolled 22 patients ages 69.5 ±8.9 years and 82 percent male with BMI 26.9±3.5 and LVEF 28.9±8.2. The common diagnoses for which the ISSD was used included: non-ischemic cardiomyopathy (18 percent), prior cardiac surgery (14 percent), and primary prevention patients (91 percent). The average implant time was 20 minutes and results include an average defibrillation testing threshold (DFT) of 25.8 joules and a SD of 10.7 joules in successfully screened patients.

“The results are very promising because not only does the subcutaneous string device provide a minimally invasive approach that lowers the risk of infection for patients, but we were also able to successfully implant the device in a short amount of time when compared to other defibrillators,” says lead author, Petr Neužil, M.D., CSc. FESC, chairman at the Department of Cardiology at Na Homolce Hospital in Prague, Czech Republic. “We’re optimistic about this innovative technology and what it means for the future of healthcare. It’s an example of how advancing technology has the potential to improve the quality of life for patients and, ultimately, improve patient outcomes.”

Watch a VIDEO interview with Neuzil on the trail at Heart Rhythm 2017.

Patients indicated for standard ICD implantation underwent acute subcutaneous insertion of the ISSD device comprised of: a 10 cm long, 5 mm diameter sternal coil, a 10 cm long, 3 mm diameter side coil and a 4 cm long, 1.5 cm diameter cylindrical metal tube called the "active segment". Defibrillation energy from an external defibrillator was delivered through these surfaces so that both the side coil and the active segment were one pole and the sternal coil was the other.

The author notes interest in expanding clinical studies to further test the device for larger patient populations and long-term efficacy.
 

Read more: heartrhythmjournal.com/article/S1547-5271(17)30589-1/fulltext

For more information: www.hrssessions.org, www.HRSonline.org

References:

1. McMaster University. "Common test used on heart patients who need defibrillator implants unnecessary: Study." ScienceDaily. ScienceDaily, 8 May 2014. <www.sciencedaily.com/releases/2014/05/140508172051.htm>
2. Zipes, DP, Roberts, D. for the Pacemaker-Cardioverter-Defibrillator investigators. “Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator: A Comparison of Epicardial and Endocardial Lead Systems.” Circulation. 1995;92:59-65.
3. Volosin et. al. “Virtual ICD: A Model to Evaluate Shock Reduction Strategies.” Heart Rhythm. Vol. 7, N. 5, May supplement 2010. (PO3-125).

Related Content

Medtronic Announces Global Resolute Onyx DES One-Month DAPT Study
News | Antiplatelet and Anticoagulation Therapies| August 18, 2017
Medtronic plc announced a global randomized clinical trial that will evaluate one-month dual antiplatelet therapy (DAPT...
The FDA is concerned about cybersecurity of ICDs and cyber security of other medical devices.
Feature | Cybersecurity| August 16, 2017 | Dave Fornell
There is growing concern among patients and regulators that medical devices, especially implantable electrophysiology
Bivalirudin exhibited an improvement in 30-day all-cause mortality when injected post PCI.
News | Antiplatelet and Anticoagulation Therapies| August 16, 2017
August 16, 2017 — A study has examined the efficacies of various post-percutaneous coronary intervention (PCI) bivali
ESC 2017 late breaking trial hot line study presentations.
News | Clinical Study| August 16, 2017
Aug. 16, 2017 – The European Society of Cardiology (ESC) Congress 2017 includes several Hot Line Late-breaking Clinic
News | Drug-Eluting Balloons| August 15, 2017
Surmodics Inc. announced receipt of an investigational device exemption (IDE) from the U.S. Food and Drug...
The Vascular Dynamics MobiusHD device enhances the carotid baroreceptors to reduce resistant hypertension.
News | Hypertension| August 15, 2017
Aug. 15, 2017 — The U.S. Food and Drug Administration (FDA) has approved the Vascular Dynamics Inc.
Abbott Initiates First Clinical Trial of Clip-Based Tricuspid Repair System
News | Heart Valve Technology| August 09, 2017
Abbott announced that the first patient has been enrolled in a clinical study to evaluate a minimally invasive clip-...
Three New Atrial Fibrillation Studies to Feature HeartLight Endoscopic Ablation System
News | Ablation Systems| August 07, 2017
CardioFocus Inc. announced that its HeartLight Endoscopic Ablation System is being featured in three new major clinical...
Overlay Init