Technology | February 25, 2013

FDA Approves First Single-Lead ICD With Atrial Sensing

Biotronik’s Lumax DX system could help patients who may benefit from atrial sensing without pacing indication

Lumax 740 DX system, ICD

February 25, 2013 — The U.S. Food and Drug Administration (FDA) granted final approval for the Biotronik Lumax 740 DX system. The device is a first-in-class implantable cardiac defibrillator (ICD) that utilizes a single lead with atrial sensing capabilities.

Single-chamber ICDs utilize a lead to deliver an electrical shock to the heart when the heart rate becomes dangerously fast. For patients who have, or are at risk of developing atrial fibrillation (AF), a physician may consider implanting a dual-chamber ICD, which utilizes two leads and has pacemaker functions built in. For the more than 70,000[1] patients in the U.S. who receive an ICD each year, device selection remains controversial.

“Until now, our only option to obtain important and useful atrial signal information from patients undergoing defibrillator implantation has been to implant a separate atrial lead. Implanting multiple leads in the heart has been shown to increase the risk of complications,[2] and the use of dual-chamber devices in patients without a clear indication for the additional atrial lead has received a great deal of attention in recent months. Until now, my approach for patients who do not require atrial pacing has been to implant single-chamber ICDs,” said Bradley P. Knight, M.D., medical director, Center for Heart Rhythm Disorders at Northwestern Memorial Hospital’s Bluhm Cardiovascular Institute.

“The DX System addresses a significant gap in ICD therapy,” he said. “Patients now have access to the benefits of both dual and single-chamber ICDs without the risk of additional hardware.”

Traditional standard single-chamber ICDs come with limitations. The devices are designed only to sense changes in ventricular rhythm and are unable to sense atrial arrhythmias, such as AF, correctly. This can result in an increased risk of an inappropriate shock[3] or a stroke[4] if AF is not detected.

The DX system expands the diagnostic capabilities of a standard single-chamber ICD with a single lead, in addition to featuring sophisticated sensors that allow for atrial monitoring and enhanced arrhythmia diagnosis. The system utilizes the LinoxsmartS DX lead. Based on proven technology, the LinoxsmartS DX utilizes an innovative floating atrial dipole. This allows physicians, for the first-time in an ICD, to capture atrial sensing capabilities with one lead. When combined with the Lumax 740 VR-T DX device — which has optimized circuitry — the system provides a reliable atrial signal. Additionally, its SMART Detection algorithms discriminate supraventricular tachycardias (SVTs), AF and atrial flutter to reduce the risk of inappropriate shocks.

“Electrophysiologists have long searched for effective diagnostics and disease management capability with a less invasive treatment. But the increased regulatory and financial obstacles associated with bringing innovative technology to market was a challenge,” said Thomas Ahern, M.D., director of cardiac electrophysiology research at Scripps Clinic. “Biotronik’s commitment to nearly a decade of research for this system has provided electrophysiologists with technology that will allow for better management of cardiac rhythm care for our patients.”

The DX System also integrates with Biotronik’s Home Monitoring,  allowing physicians to remotely follow their DX patients’ clinical and device statuses daily, at anytime, anywhere in the world. The cellular-based system has demonstrated the ability to detect clinically relevant events, including silent, asymptomatic arrhythmias,[6]and device related issues,[1] allowing for earlier medical intervention. The diagnostic capabilities of the DX system combined with Home Monitoring makes this a simple, yet sophisticated system for cardiac rhythm management.

The DX System is now approved and currently available in most international markets (including the European Union and Japan. Biotronik expects to begin U.S. implants in late February/early March.

For more information:


[1] Biotronik data on file

[2] Dewland, TA. Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry. J Am Coll Cardiol.. 2011 Aug 30;58(10):1007-13. doi: 10.1016/j.jacc.2011.04.039.

[3] Daubert, JP. Et al; Inappropriate implantable cardioverter-defibrillator shocks in MADIT II, JACC 2008; 51: 1357-6.

[4] National Stroke Association. Controllable Risk Factors – Atrial Fibrillation. 2013.

[5] Biotronik data on file

[6] Varma N, Epstein AE, Irimpen A, Schweikert R, Love C, for the TRUST investigators. Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T safely reduces routine office device follow-up (TRUST) Trial. Circulation. 2010;122:325-332 follow-up: The Lumos-T safely reduces routine office device follow-up (TRUST) Trial. Circulation. 2010;122:325-332

[7] Varma N, Michalski J, Epstein AE, Schweikert R. Automatic remote monitoring of implantable cardioverter-defibrillator lead and generator performance: The Lumos-T safely reduces routine office device follow-up (TRUST) Trial. Circulation Arrhythmia and Electrophysiology. 2010;3:428-436

Related Content

Boston Scientific's Apama multi-electrode ablation balloon to treat atrial fibrillation.

Boston Scientific's Apama multi-electrode ablation balloon to treat atrial fibrillation. The technology allows different energies to be used for each electrode to prevent damage to the esophagus or other underlying critical structures. 

Feature | Atrial Fibrillation | January 15, 2018 | Dave Fornell
The development of atrial fibrillation (AFib or AF) ablation technologies over the past 20 years has been a constant
Heart Rhythm Society Partners With WebMD Education to Increase Atrial Fibrillation Awareness
News | Atrial Fibrillation | January 02, 2018
The Heart Rhythm Society (HRS), in partnership with WebMD Education, announced in December the launch of a free, online...
The Boston Scientific Rhythmia Mapping System produces higher-density voltage maps without increasing overall procedure time.

The Boston Scientific Rhythmia Mapping System produces higher-density voltage maps without increasing overall procedure time. It was the first of a new generation of high-density mapping systems to be introduced.

Feature | Atrial Fibrillation | December 18, 2017 | Kenneth Stein, M.D. FACC FHRS
When I began practicing as an electrophysiologist in 1994, the dream of successfully using cardiac catheter ablation
Acutus dipole density EP mapping for ablation procedures.

The FDA recently cleared high-speed Acutus Medical's AcQMap High Resolution image and mapping system and the AcQMap 3-D Imaging and Mapping Catheter.  detects and displays both standard voltage-based and higher resolution dipole density (charge-source) maps. The system combines ultrasound anatomy construction with an ability to map the electrical-conduction of each heartbeat to identify complex arrhythmias across the entire atrial chamber. Following each ablation treatment, the heart can be re-mapped in seconds to continually visualize any changes from the prior mapping.



Feature | Atrial Fibrillation | November 07, 2017
November 7, 2017 — Here is an aggregated list of articles detailing the latest clinical data and new device technolog
The Watchman LAA occluder PREVAIL Trial 5-year results were presented at the 2017 TCT meeting.
Feature | Atrial Fibrillation | November 02, 2017
November 2, 2017 – Five-year results from the PREVAIL Trial comparing left atrial appendage closure (LAAC) with the B
UNC School of Medicine Receives $1.7 Million for Atrial Fibrillation Program Streamlining Patient Care
News | Atrial Fibrillation | October 23, 2017
October 23, 2017 — University of North Carolina (UNC) School of Medicine cardiologist Anil Gehi, M.D., will use a $1.
EMANATE Trial Shows Apixaban Lowers stroke in AF Patients Undergoing Cardioversion.
News | Atrial Fibrillation | September 01, 2017
September 1, 2017 — Apixaban lowers the risk of stroke compared to warfarin in anticoagulation-naïve patients with at
CASTLE-AF Study shows Catheter Ablation of Atrial Fibrillation is First-Line Treatment for Heart Failure Patients. Biotronic Ilivia 7 ICD.

The CASTLE-AF Study shows catheter alation of AF can be used effectively to treat heart failure in patients with an implanted ICD.

News | Atrial Fibrillation | September 01, 2017
September 1, 2017 — Final results from the CASTLE-AF study show a 38 percent reduction in the composite of all-cause