Technology | Computed Tomography (CT) | October 09, 2017

Medis Releases QAngio CT v3.1

Coronary plaque burden analysis software now offers enhanced access to CT angiography studies across the network, ability to analyze multiple vessels at the same time

Medis Releases QAngio CT v3.1

October 9, 2017 — Medis has released a new version of its QAngio CT (computed tomography), which can now be launched from the Medis Suite imaging platform. QAngio CT v3.1 provides a detailed analysis of plaque burden of the coronary system with comprehensive results.

Features of QAngio CT include:

Data import

  • Support for CT angiography (CTA) studies of all major CT vendors;
  • Access to CTA studies across the network;
  • Import of CTA studies from local storage media (hard disk, USB and CD/DVD);
  • DICOM connectivity, receiving cases, and query and retrieve;
  • Centralized database, thick client solution possible with multiple clients;
  • Loading of prior exams in parallel.

Viewing

  • Viewing 3-D CTA series, double oblique viewing, MPR, MIP, slabbed MIP, VR; and
  • Efficient caliper measurements.

CTA analysis workflow

  • Fully automatic extraction of the complete coronary tree;
  • Semi-automatic editing of coronary tree;
  • Automatic labeling of the segments in the coronary tree with anatomical names;
  • Analyze multiple vessels at the same time;
  • A two-step contour detection approach per vessel for both lumen and vessel contours:
    • Longitudinal detection: provides quick overview of border and allows easy corrections which will propagate to the transversal step.
    • Transversal detection: Based on the longitudinal contours and corrections.
    • Edit contours in longitudinal and transversal images simultaneously; and
  • Flexible lesion detection and definition using synchronized views of the vessel data (stretched MPR, curved MPR, graphs).
    • Simple contour editing workflow (two steps)
    • Automatic segment labeling for reporting and statistics

CTA analysis results

  • Lumen and plaque statistics:
    • Degree of stenosis (diameter and area)
    • Lesion length
    • Plaque burden
    • Plaque volume (per lesion and per vessel)
    • Vessel remodeling index
    • Mean plaque and lumen intensities
  • Fixed and adaptive thresholding methods for plaque characterization;
  • Plaque characterization components according to Virtual Histology classification; and
  • Vessel segment labeling.

Data export

  • All analysis results including coronary tree, contours, lesion parameters and vessel labels can be saved and reloaded again for reviewing and/or exporting;
  • Easy data export for quantification data (Excel or copy-to-clipboard);
  • Batch processing of quantified parameters from multiple studies into a single spreadsheet
    • Segment based
    • Lesion based
    • Slice based; and
  • Screenshots (jpeg, png, copy to clipboard, DICOM snapshots).

For more information: www.medis.nl

Related Content

An example of perivascular fat attenuation index (FAI) imaging inside the coronary vascular wall to show areas of inflammation. #SCCT2020

An example of perivascular fat attenuation index (FAI) imaging inside the coronary vascular wall to show areas of inflammation. The technology was created by Oxford University and several experts in cardiac CT imaging say this might be a game changer to improving risk assessments.

Feature | CT Angiography (CTA) | July 30, 2020 | Dave Fornell, Editor
There is a promising recent development in...
A cardiac CT of a patient with pacemaker leads, which can be challenging to get good images due to metal artifact. This image was rendered from using Canon's AiCE AI-assisted interactive reconstruction with Global Illumination 3-D rendering from a scan on an Aquilion One Genesis SP system.

A cardiac CT of a patient with pacemaker leads, which can be challenging to get good images due to metal artifact. This image was rendered from using Canon's AiCE AI-assisted interactive reconstruction with Global Illumination 3-D rendering from a scan on an Aquilion One Genesis SP system.

Feature | CT Angiography (CTA) | July 27, 2020 | Dave Fornell, Editor
There has been tremendous growth in the field of cardiovascular...
The new Aquilion One Genesis SP cardiac CT system uses artificial intelligence to help reconstruct low dose cardiac CT images. #SCCT2020

The new Aquilion One Genesis SP cardiac CT system uses artificial intelligence to help reconstruct low dose cardiac CT images.

News | CT Angiography (CTA) | July 20, 2020
July 20, 2020 – To meet the growing cardiovascular imaging needs of healthcare systems, Canon Medical Systems USA is
Canon displays new CT technologies in its virtual SCCT 2020 booth.
News | CT Angiography (CTA) | July 06, 2020
Canon Medical Systems USA has created a virtual trade-show experience for its cardiovascular computed tomography (CT)
Two examples of CT myocardial perfusion (CTP) imaging assessment software. Canon is on the left and GE Healthcare is on the right. Both of these technologies have been around for a few years, but there have been an increasing amount of clinical data from studies showing the accuracy of the technology compared to nuclear imaging, the current stand of care for myocardial perfusion imaging, and cardiac MRI.

Two examples of CT myocardial perfusion (CTP) imaging assessment software. Canon is on the left and GE Healthcare is on the right. Both of these technologies have been around for a few years, but there has been an increasing amount of clinical data from studies showing the accuracy of the technology compared to nuclear imaging, the current standard of care for myocardial perfusion imaging, and cardiac MRI.

Feature | CT Angiography (CTA) | June 08, 2020 | Dave Fornell, Editor
Here is an overview of a few of the biggest technology advances in...
Two examples of CT myocardial perfusion (CTP) imaging assessment software. Canon is on the left and GE Healthcare is on the right. Both of these technologies have been around for a few years, but there have been an increasing amount of clinical data from studies showing the accuracy of the technology compared to nuclear imaging, the current stand of care for myocardial perfusion imaging, and cardiac MRI. #SCCT #perfusionimaging 

Two examples of CT myocardial perfusion (CTP) imaging assessment software. Canon is on the left and GE Healthcare is on the right. Both of these technologies have been around for a few years, but there have been an increasing amount of clinical data from studies showing the accuracy of the technology compared to nuclear imaging, the current stand of care for myocardial perfusion imaging, and cardiac MRI.

News | CT Angiography (CTA) | March 16, 2020
March 16, 2020 — The Society of Cardiovascular Computed Tomography (SCCT) released a new...
New ESC Guideline Provides Class 1 Recommendation for Coronary CTA
News | CT Angiography (CTA) | September 17, 2019
The European Society of Cardiology (ESC) published new ...
HeartFlow Announces FDA Clearance for HeartFlow Planner
Technology | CT Angiography (CTA) | September 12, 2019
HeartFlow Inc. has obtained clearance from the U.S. Food and Drug Administration (FDA) for the HeartFlow Planner, a non...
Gallery | CT Angiography (CTA) | August 08, 2019 | Dave Fornell, Editor
This is a photo essay of the ca...