Medtronic NC Euphora Coronary Balloon Receives FDA Clearance

September 11, 2014 — Medtronic announced the U.S. Food and Drug Administration (FDA) 510(k) clearance and launch of the NC Euphora noncompliant balloon dilatation catheter. The new device will be featured for the first time in the United States at the Medtronic booth at the upcoming Transcatheter Cardiovascular Therapeutics (TCT) meeting in Washington, D.C.

Following drug-eluting stent (DES) implantation to reopen a narrowed artery, a noncompliant balloon is inflated with high pressure to ensure the stent is fully apposed in order to facilitate transfer of the drug to the artery wall. Stent under-expansion has been defined as a major risk factor for both artery re-narrowing, or restenosis, and the potential formation of blood clots (stent thrombosis). Postdilatation with noncompliant balloons has been recommended to overcome these complications and provide optimal stent expansion after stent placement.

“When developing NC Euphora, insights from the entire cath lab team were gathered and addressed to ensure it meets the current needs of cath lab professionals in device design and performance,” said David Kandzari, M.D., director of interventional cardiology and chief scientific officer at the Piedmont Heart Institute in Atlanta. “The advanced design characteristics of NC Euphora provide physicians with a reliably deliverable noncompliant balloon catheter to ensure success in challenging coronary angioplasty procedures.”

The NC Euphora balloon catheter was designed for uncompromising performance to provide clinicians with several valuable features, including:

  • PowerTrac technology to provide superior deliverability through challenging lesions and require less force to track through tortuous anatomy;
  • An optimized tapered tip design and low-lesion entry profile that improves flexibility and allows for reliable stent re-cross when traversing long, challenging lesions so the balloon does not catch on a strut when passing through a deployed stent.
  • Strong and flexible proprietary balloon material provides high-pressure capability, which enables NC Euphora to expand consistently within the stent area at a rated burst pressure of up to 20 atmospheres without bursting.
  • Significantly low radial growth to reduce unwanted vessel expansion and low longitudinal growth beyond the stent length to minimize damage to the surrounding healthy artery.
  • Environmentally friendly packaging and a reduced box size that has a smaller footprint on congested shelves and a broad size range labeled clearly and intuitively.


“The advanced features of NC Euphora demonstrate that not all balloon catheters are the same,” said Chad Dupree, RT(R), cath lab staff member at the Piedmont Heart Institute. “The cath lab team recognizes that balloon catheters are a key component of the procedure, and availability of a device that optimizes stent deployment presents a key opportunity that we have to achieve procedural success.”

For more information: www.medtronic.com

Related Content

Tryton Side Branch Stent Recognized With Premier Technology Breakthrough Award
News | Stents Bifurcation| September 21, 2017
September 21, 2017 — Cardinal Health and Tryton Medical Inc.
DISRUPT BTK Study Shows Positive Results With Lithoplasty in Calcified Lesions Below the Knee
News | Peripheral Artery Disease (PAD)| September 20, 2017
Shockwave Medical reported positive results from the DISRUPT BTK Study, which were presented at the annual...
Corindus Announces First Patient Enrolled in PRECISION GRX Registry
News | Robotic Systems| September 18, 2017
September 18, 2017 — Corindus Vascular Robotics Inc.
Two-Year ILLUMENATE Trial Data Demonstrate Efficacy of Stellarex Drug-Coated Balloon
News | Drug-Eluting Balloons| September 18, 2017
Philips announced the two-year results from the ILLUMENATE European randomized clinical trial (EU RCT) demonstrating...
Sentinel Cerebral Protection System Significantly Reduces Stroke and Mortality in TAVR
News | Embolic Protection Devices| September 18, 2017
September 18, 2017 – Claret Medical announced publication of a new study in the...
Fysicon Receives FDA Approval for QMAPP Hemodynamic Monitoring System
Technology | Hemodynamic Monitoring Systems| September 18, 2017
Fysicon announced that it has been granted 510(k) clearance by the U.S. Food and Drug Administration (FDA) for its...
Peter Schneider, M.D. presents late breaking clinical trial results at VIVA 17 in Las Vegas. Panelists (l to r) Krishna Rocha-Singh, M.D., Sean Lyden, M.D., John Kaufman, M.D., Donna Buckley, M.D.

Peter Schneider, M.D. presents late breaking clinical trial results at VIVA 17 in Las Vegas. Panelists (l to r) Krishna Rocha-Singh, M.D., Sean Lyden, M.D., John Kaufman, M.D., Donna Buckley, M.D.

Feature | Cath Lab| September 14, 2017
September 14, 2017 — Here are quick summaries for all the key late-breaking vascular and endovascular clinical trials
Mississippi Surgical and Vascular Center Uses Toshiba Ultimax-i FPD to Save Patients' Limbs
News | Angiography| September 14, 2017
The southern U.S. sees some of the highest numbers of chronic medical conditions, such as peripheral artery disease...
Sponsored Content | Videos | Structural Heart Occluders| September 13, 2017
Ziyad Hijazi, M.D., MPH, MSCAI, FACC, director of the cardiac program and chair of the Department of Pediatrics at Si
Philips Showcases Integrated Vascular Solutions at VIVA 2017
News | Peripheral Artery Disease (PAD)| September 13, 2017
Philips announced its presence at the Vascular Interventional Advances (VIVA 17) Annual Conference in Las Vegas from...
Overlay Init