Feature | September 10, 2014

Authors Say Contrast-Enhanced CT Safe for Most Patients

Contrast-Enhanced CT Safe for Most Patients. Patient Dave Fornell.

September 10, 2014 — According to new research performed at the Mayo Clinic, iodine-based contrast material injected intravenously to enhance computed tomography (CT) images can be safely used in most patients. The study appears online in the journal Radiology.

Of the 80 million or more CT scans performed each year in the United States, iodine-based contrast material is used in at least half to enhance CT images, according to researcher Robert J. McDonald, M.D., Ph.D., a radiology resident at the Mayo Clinic in Rochester, Minn.

According to McDonald, a small number of case reports from the 1950s and, more recently, retrospective studies lacking appropriate control groups causally linked the use of iodine-based contrast CTs to kidney damage, a condition called contrast-induced nephropathy.

“For nearly 60 years, physicians have worried about contrast-induced nephropathy when using iodinated contrast material, particularly for patients with impaired kidney function,” McDonald said. “Emerging evidence now suggests these concerns are likely vastly overestimated.”

McDonald and a team of researchers analyzed information on patients who underwent abdominal, pelvic and thoracic CT scans at the Mayo Clinic between 2000 and 2010. A study group of 21,346 patients included 10,673 patients who each underwent a contrast-enhanced CT exam and 10,673 patients who underwent a similar CT without intravenous contrast. The two groups were closely matched by demographic and clinical characteristics, including gender, race and pre-existing conditions such as diabetes, congestive heart failure and acute renal disease.

The researchers analyzed the patient data for adverse events following the CT scans, including acute kidney injury, the need for emergency renal dialysis (in patients with no prior history of dialysis) and death within 30 days of contrast exposure.

The analysis revealed no significant difference in the rate of acute kidney injury between patients in the contrast group (4.8 percent, or 515 of 10,673) and the non-contrast group (5.1 percent or 544 of 10,673). More importantly, the rates of emergency dialysis and death in the 30-day window following CT examination were not significantly different between patients exposed to contrast and those who were not exposed. These results were also observed among patients with compromised kidney function and high-risk conditions, such as congestive heart failure and diabetes, which are assumed to predispose a patient to kidney injury.

“These results challenge long-held assumptions regarding the presumed nephrotoxic risk of intravenous contrast material,” McDonald said. “We hope that our findings will help refine the safety profile of these contrast agents."

For more information: www.radiologyinfo.org

Related Content

Hitachi Supria True64 CT Receives FDA Clearance
Technology | Computed Tomography (CT)| September 15, 2017
Hitachi Healthcare Americas Inc. announced it has attained U.S. Food and Drug Administration (FDA) 510(k) clearance to...
Orange County, Calif. Hospital Adopts Siemens Somatom Force CT for Cardiac Imaging
News | Computed Tomography (CT)| September 12, 2017
Hoag Memorial Hospital Presbyterian recently became the first hospital in Orange County, Calif., to install the Siemens...
Technology | Radiation Dose Management| September 07, 2017
September 7, 2017 — Sapheneia and Scannerside received U.S.
FDA Holds MIDAC Meeting on Gadolinium-Based Contrast Agents. Image by Marilyn Fornell
News | Contrast Media| September 07, 2017
The U.S. Food and Drug Administration (FDA) announced it would hold a meeting of the Medical Imaging Drugs Advisory...
European Medicines Agency Issues Update on Gadolinium Contrast Agents
News | Contrast Media| August 29, 2017
August 29, 2017 — The European Medicines Agency (EMA) issued a final opinion that recommended restricting the use of
Philips is partnering with HeartFlow to co-develop new FFR-CT and FFR-angiography imaging technologies.
News | FFR Technologies| August 28, 2017
August 28, 2017 — Philips Healthcare and HeartFlow Inc.
St. Cloud Hospital Installs Toshiba Aquilion One Genesis CT for Emergency Department
News | Computed Tomography (CT)| August 23, 2017
Central Minnesota residents now have access to advanced computed tomography (CT) technology that is safe and fast at St...
Houston Methodist Hospital Enters Multi-Year Technology and Research Agreement With Siemens Healthineers
News | Cardiac Imaging| August 17, 2017
Houston Methodist Hospital and Siemens Healthineers have entered into a multi-year agreement to bring cutting-edge...
ISMRM Issues Guidelines for MRI Gadolinium Contrast Agents
News | Magnetic Resonance Imaging (MRI)| August 15, 2017
The International Society for Magnetic Resonance in Medicine (ISMRM) has provided new guidance in the use of contrast...
Four Blue Cross Blue Shield Companies Issue Positive Medical Policies on HeartFlow FFRct Analysis
News | FFR Technologies| August 09, 2017
HeartFlow Inc. announced that four Blue Cross Blue Shield companies have each issued a positive medical policy for the...
Overlay Init