News | Angiography | April 06, 2022

Dixon GRE Technique Outperforms Clinical Standard for Unenhanced Coronary MRA

Study included 44 patients with intermediate-to-high risk of coronary artery disease who underwent both 1.5-T SSFP and 3-T Dixon GRE coronary MRA examinations before coronary angiography.

According to ARRS’ American Journal of Roentgenology (AJR), the 3-T Dixon gradient-recalled echo (GRE) sequence performed higher than the current standard of 1.5-T SSFP for unenhanced coronary MRA, which could help expand clinical adoption of the procedure.

A 60-year-old man with chest pain. (A) Image from coronary angiogram shows no significant stenosis of right coronary artery (RCA). (B) Curved multiplanar reformatted image from 1.5-T SSFP coronary MRA shows severe stenosis of mid RCA (arrow), representing a false-positive finding. (C) Curved multiplanar reformatted image from 3-T Dixon GRE coronary MRA shows no RCA stenosis.


April 6, 2022 – According to ARRS’ American Journal of Roentgenology (AJR), the 3-T Dixon gradient-recalled echo (GRE) sequence performed higher than the current standard of 1.5-T SSFP for unenhanced coronary MRA, which could help expand clinical adoption of the procedure.

“For unenhanced coronary MRA, 3-T unenhanced Dixon GRE had better image quality and diagnostic performance than 1.5-T SSFP, particularly for distal and branch segments,” wrote lead researcher Hang Jin from China’s Fudan University and Shanghai Institute of Medical Imaging.

Jin and team’s prospective study included 44 patients (27 men, 17 women; mean age, 59 years) with intermediate-to-high risk of coronary artery disease who underwent both 1.5-T SSFP and 3-T Dixon GRE coronary MRA examinations before coronary angiography. Two radiologists independently assessed coronary arteries in random order for subjective image quality, number of visible segments, apparent contrast-to-noise ratio, and presence of significant stenoses.

Compared with 1.5-T SSFP, coronary MRA using 3-T unenhanced Dixon GRE demonstrated higher image quality (4.0±1.1 vs 3.0±1.2), higher percentage of visible coronary segments (96.7% vs 88.9%), as well as higher sensitivity (87.9% vs 77.3%) and specificity (83.3% vs 60.6%) for significant stenoses on a per-vessel basis, using coronary angiography as reference.

“The present results demonstrate the benefits of robust epicardial fat suppression using Dixon GRE in terms of improved apparent contrast-to-noise and improved visibility, with the latter difference observed particularly for distal and branch segments that course close to the myocardium,” the authors of this AJR article concluded.

Reference:

Unenhanced Whole-Heart Coronary MRA: Prospective Intraindividual Comparison of 1.5-T SSFP and 3-T Dixon Water-Fat Separation GRE Methods Using Coronary Angiography as Reference
 


Related Content

News | Angiography

April 25, 2025 — The annual Society for Cardiovascular Angiography & Interventions (SCAI) meeting, SCAI 2025 Scientific ...

Home April 25, 2025
Home
News | Angiography

March 17, 2025 – Ostial Corp., a privately held medical technology company focused on addressing the clinical challenges ...

Home March 18, 2025
Home
News | Angiography

SCAI Scientific Sessions 2025 will take place May 1 to 3, at the Walter E. Washington Convention Center in Washington ...

Home March 14, 2025
Home
News | Angiography

Oct. 7, 2024 — The Society for Cardiovascular Angiography & Interventions (SCAI) recently announced the publication of ...

Home October 07, 2024
Home
News | Angiography

January 31, 2024 — Coronary artery calcification is increasing in prevalence, leading to greater risks both during ...

Home January 31, 2024
Home
Feature | Angiography | By Bhvita Jani

The world market for interventional X-ray and mobile C-arm equipment is forecast to reach over $4.9 billion by 2026 ...

Home November 09, 2022
Home
News | Angiography

April 7, 2021 — Philips Healthcare announced U.S. Food and Drug Administration (FDA) 510(k) clearance for its Philips ...

Home April 07, 2021
Home
Feature | Angiography | By Bhvita Jani

January 19, 2021 – With the postponement of non-essential elective surgeries and medical procedures in 2020 to conserve ...

Home January 19, 2021
Home
News | Angiography

December 3, 2020 — GE Healthcare is introducing a new version of its robotic driven angiography system for image guided ...

Home December 01, 2020
Home
Feature | Angiography | Dave Fornell, Editor

Philips is working on a prototype cath lab angiographic imaging system that might be able to replace the current X-ray ...

Home March 12, 2020
Home
Subscribe Now