News | Angiography | March 10, 2017

Miniature Particle Accelerator Saves on Contrast Agents for Angiography

X-rays from the MuCLS compact synchrotron at Technical University of Munich open up new possibilities for heart examinations

Technical University of Munich, Munich Compact Light Source, MuCLS, angiography, contrast agents

March 10, 2017 — The most prevalent method for obtaining images of clogged coronary vessels is coronary angiography. For some patients, however, the contrast agents used in this process can cause health problems. A team at the Technical University of Munich (TUM) has now demonstrated that the required quantity of these substances can be significantly reduced if monoenergetic X-rays from a miniature particle accelerator are used.

Soft tissues such as organs and blood vessels are nearly impossible to examine in X-ray images. To detect a narrowing or other changes in coronary blood vessels, patients are therefore usually injected with an iodinated contrast agent.

These substances can sometimes be hazardous to health, however: "Particularly in patients with kidney insufficiency, complications may arise, in some cases even kidney failure," explained Daniela Münzel, M.D., an adjunct teaching professor for radiology at TUM's Klinikum rechts der Isar. "That is why we are studying possibilities of using lower concentrations of contrast agents."

One approach to reducing the dosage has now been developed by scientists from the Department of Diagnostic and Interventional Radiology at the Klinikum rechts der Isar, working in close cooperation with the Chair of Biomedical Physics at TUM's Department of Physics. The method, which they have described in a paper published in Nature Scientific Reports, is not based on new contrast agents. Instead it relies on special X-rays generated using the Munich Compact Light Source (MuCLS), the world's first mini-synchrotron, which was officially inaugurated at TUM at the end of 2015.

"Conventional X-ray sources generate a relatively broad range of energy levels. By contrast, the energy of X-rays produced by the MuCLS can be controlled much more precisely," said physicist Elena Eggl, the first author of the paper.

Contrast agents such as iodine and gadolinium have an absorption edge. That means that when the substance is exposed to X-rays of a certain energy, the contrast of the final image of the marked organ is particularly good. Below the absorption edge — about 30 kiloelectron volts (keV) for iodine — the contrast deteriorates rapidly. The contrast also becomes weaker at energies far above the absorption edge.

As a result, when using conventional broad-spectrum X-ray sources, an adequate quantity of contrast agent must always be used in order to offset this effect and obtain a sufficiently sharp image for a diagnosis. The MuCLS can generate X-rays that have exactly the optimal energy level. The capability of producing such monoenergetic X-rays has existed for some time. In the past, however, this was possible only with circular particle accelerators with a diameter of several hundred meters. In contrast, the MuCLS is comparable in size to a car.

The data shows that monoenergetic X-rays would make it possible to decrease the required concentration of iodine by about one third with no loss of contrast. For gadolinium, there would even be a somewhat greater reduction. A lot more research is needed, however, before real patients can be examined with monoenergetic X-rays.

"We're still at the very beginning of the development of this technology," said Eggl. The MuCLS is the very first machine of its kind. Moreover, it is designed for fundamental research, and not for examining patients. But with detailed computer simulations and tests with a pig's heart, using blood vessels dyed with iodine, the researchers were able to demonstrate feasibility of the method.

Franz Pfeiffer, professor of biomedical physics at TUM, sees the team's results as a promising start for medical research with the compact synchrotron: "The MuCLS offers numerous possibilities for medical applications that we plan to continue researching with our partners in medical fields,” he said.

The research was funded by the German Research Foundation (DFG), Munich-Centre for Advanced Photonics (MAP) cluster of excellence, the Center for Advanced Laser Applications (CALA), the Ministry for Education and Research, and the DFG Gottfried Wilhelm Leibniz Program.

For more information: www.nature.com/srep

References
Eggl E.,  Mechlem K., Braig E., Kulpe S., et al. "Mono-Energy Coronary Angiography with a Compact Synchrotron Source". Scientific Reports. Published online Feb. 9, 2017. DOI:10.1038/srep42211


Related Content

News | Angiography

January 31, 2024 — Coronary artery calcification is increasing in prevalence, leading to greater risks both during ...

Home January 31, 2024
Home
Feature | Angiography | By Bhvita Jani

The world market for interventional X-ray and mobile C-arm equipment is forecast to reach over $4.9 billion by 2026 ...

Home November 09, 2022
Home
News | Angiography
April 6, 2022 – According to ARRS’ American Journal of Roentgenology (AJR), the 3-T Dixon gradient-recalled echo (GRE) ...
Home April 06, 2022
Home
News | Angiography

April 7, 2021 — Philips Healthcare announced U.S. Food and Drug Administration (FDA) 510(k) clearance for its Philips ...

Home April 07, 2021
Home
Feature | Angiography | By Bhvita Jani

January 19, 2021 – With the postponement of non-essential elective surgeries and medical procedures in 2020 to conserve ...

Home January 19, 2021
Home
News | Angiography

December 3, 2020 — GE Healthcare is introducing a new version of its robotic driven angiography system for image guided ...

Home December 01, 2020
Home
Feature | Angiography | Dave Fornell, Editor

Philips is working on a prototype cath lab angiographic imaging system that might be able to replace the current X-ray ...

Home March 12, 2020
Home
News | Angiography

February 12, 2020 — The University of Wisconsin (UW) Health’s University Hospital in Madison, Wis., recently became the ...

Home February 12, 2020
Home
News | Angiography

October 9, 2019 — In the complex and fast-paced world of healthcare, customers face the challenge of staying up-to-date ...

Home October 09, 2019
Home
Technology | Angiography

September 17, 2019 — The U.S. Food and Drug Administration (FDA) has cleared the Artis icono, a high-precision family of ...

Home September 17, 2019
Home
Subscribe Now