News | July 08, 2007

PET-CT Generates False-Positives in Atherosclerosis

July 9, 2007 - A study published in the Journal of Nuclear Medicine reports that current PET-CT scanners with standard commercial software designed to provide images of the heart falsely indicated coronary artery disease in as many as 40 percent of 259 patients.

Lead author K. Lance Gould, M.D., professor in the Division of Cardiology at The University of Texas Medical School at Houston, said that an erroneous basic concept in the software functions make the PET-CT scanners prone to generating false-positive results. According to Gould, the commercial software does not account for movement in the lungs and heart while the patient is breathing during the test, and the PET and CT images don’t always co-register.
"Consequently, the images have big holes or gaps where the processing is incorrect in areas where the PET and CT data fail to match," Gould said. "It looks like someone has severe disease."
In 23 percent of patients participating in the study, there were severe false abnormalities suggesting heart disease, for which Gould ran additional tests to confirm his suspicions of the inaccurate results.

For more information: www.jnm.snmjournals.org

Related Content

Bruker Introduces New High-Performance Preclinical PET/CT Si78 System
Technology | PET-CT | September 26, 2018
September 26, 2018 — Bruker recently announced the introduction of the new preclinical...
FDA Clears New Imaging Functionalities for Biograph mCT PET/CT Systems
Technology | PET-CT | June 21, 2018
Siemens Healthineers will announce U.S. Food and Drug Administration (FDA) clearance of four new system features for...
Nuclear myocardial perfusion scan performed on a Biograph Vision positron emission tomography/computed tomography (PET-CT) system from Siemens Healthineers. The image shows good clarity with delineation of the left ventricular edge and papillary muscles without cardiac gating.

Nuclear myocardial perfusion scan performed on a Biograph Vision positron emission tomography/computed tomography (PET-CT) system from Siemens Healthineers. The image shows good clarity with delineation of the left ventricular edge and papillary muscles without cardiac gating.

Technology | PET-CT | June 05, 2018
June 5, 2018 — The U.S.
New PET-CT Scan Improves Detection in Rare Cardiac Condition
News | PET-CT | July 25, 2017
Using a new imaging technique that can diagnose cardiac sarcoidosis much more accurately than traditional tests,...
PET/CT, calcium blockages, heart attack risk, Intermountain study, American Heart Association, AHA Scientific Sessions 2016
News | PET-CT | November 15, 2016
Many people who experience chest pain but don’t have a heart attack breathe a big sigh of relief when a stress test...
PET/CT, atherosclerotic plaque detection, Stanford University

Application of dual-modality optical and PET/CT activity-based probe in experimental carotid inflammation model. Coronal noninvasive PET/CT scans of (A) healthy and (B) diseased mice with and without ligated carotid arteries respectively. Inset images show optical ex vivo florescence imagining of (A) healthy and (B) diseased carotid arteries.  PET/CT and optical images courtesy of Xiaowei Ma, Toshinobu Saito and Nimali Withana.

News | PET-CT | November 01, 2016
Researchers at Stanford University have demonstrated for the first time the use of a dual optical and positron emission...
GE Healthcare, Discovery MI PET/CT system, FDA clearance, RSNA 2016
Technology | PET-CT | October 05, 2016
GE Healthcare recently announced U.S. Food and Drug Administration (FDA) 510(k) clearance of its Discovery MI digital...
PET/CT scan, brain stress center, heart disease predictor, ACC.16
News | PET-CT | April 05, 2016
New research shows individuals with a greater degree of activity in the stress center of the brain also have more...
Siemens, Biograph Horizon PET CT, FDA clearance
Technology | PET-CT | January 21, 2016
Siemens Healthcare has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) for the Biograph...
Toshiba, Celesteion, Steinberg Diagnostic Medical Imaging, U.S., first
News | PET-CT | June 08, 2015
Steinberg Diagnostic Medical Imaging (SDMI) of Las Vegas has bolstered its capabilities by installing the United...
Overlay Init