Case Study | July 15, 2011

Simplifying Computed Tomography Angiography (CTA)

While CTA is a complex procedure, Philips Ingenuity CT has advanced features to simplify CTA planning, acquisition and analysis

A low-dose neuro CTA using a Philips Ingenuity CT.

Pulmonary CTA using an Ingenuity CT scanner.

Computed tomography angiography (CTA) is one of the most complex procedures routinely performed on a CT scanner. A successful CTA exam requires synchronization of the timing of the scan with maximum vessel contrast enhancement.

Several factors influence vessel enhancement. Some are patient-related, such as weight and cardiac output, while others are related to contrast, such as concentration and injection rate. It is well established that maximum vessel enhancement benefits from optimal contrast volume, injection rate, and contrast concentration. Modifying injection protocols for various patient populations can be quite challenging.

Further challenges in CTA
The latest generation of CT scanners offers wide coverage and fast rotation speeds, requiring updated contrast injection protocols to take full advantage of scanner features. CTA scans are also challenging from a post-processing perspective because they require significant 3-D analysis for visualization and measurement of the vessel and its lumen.


With its patient focus and clinical integration, Philips Ingenuity CT provides the necessary tools and dedicated workflow to perform a successful CTA exam time after time. Following are some of the features:


SyncRight — The Philips SyncRight option provides seamless integration between the injector and scanner, facilitating the workflow of a CTA exam. Benefits of this include the ability to edit and view scanner and injection parameters and results using the scanner console. SyncRight simplifies operations and enhances overall consistency by streamlining workflow and reducing decision points by up to 50 percent. With SyncRight, the user can:
    •    Automatically load the injection protocol from the exam card to the injector
    •    Modify the injection protocol through scanner/injector console
    •    View injection timings and planned scan timings on scanner console
    •    Start injection and timed scans from scanner/injector console
    •    Produce the injection report as part of the exam summary series


Bolus tracking — BolusPro software on Philips Ingenuity CT allows the user to synchronize the start of the scan with predefined vessel enhancement. The user can place a region of interest on a vessel and define a Hounsfield unit threshold. Reaching a predefined threshold for vessel enhancement triggers the start of CT scanning.


Other tools on the Ingenuity CT allow users to manage the radiation dose involved in a CTA exam without compromising clinical details. Ingenuity CT also allows enhanced visualization of iodine versus calcium in the vessels.


Dose modulation — The Ingenuity CT scanner has several dose modulation features that reduce the radiation dose delivered to the patient:
    •    Automatic current setting for each patient based on patient size
    •    Longitudinal modulation of the tube current according to patient attenuation at every table position (ZDOM)
    •    Combined longitudinal and angular modulation of tube current (3DDOM)


In-room controls — The user can position the patient and start/stop the scan after setting up the IV contrast in the scan room. The in-room countdown to X-ray “ON” updates the user on the amount of time left to leave the room before the X-ray starts.
Automatic MPR creation — Results driven scanning on Ingenuity creates automatic MPRs as predefined by the exam card. The user can save the needed MPRs for a particular exam as a part of the exam card for automatic generation after the scan is completed.
Scannable range — The scanner has a scannable range of 2000 mm, allowing the user to scan lower extremities of patients with peripheral arterial disease (PAD).


Advanced Vessel Analysis — The Advanced Vessel Analysis (AVA) package on the Extended Brilliance Workspace (EBW), Brilliance Workspace Portal, and IntelliSpace Portal provides automatic bone removal, vessel extraction with centerline creation, and labeling. This automatic processing noticeably simplifies workflow with rapid creation of results. The package also allows measurement and quantification of stenosis and aneurysm within a vessel, and also provides stent planning, generating a report with all measurements to send to the referring physician.


Dose reporting — A summary of the radiation dose delivered to the patient is saved with the patient’s exam and sent to PACS for future reference.


Contrast reporting — A summary of the patient injection parameters is saved with the patient’s exam and sent to PACS for future reference on the contrast dose delivered to the patient.


This case study was supplied by Philips Healthcare.


For more information: www.healthcare.philips.com/main/products/ct/products/ingenuity_ct_scanner
 

Related Content

FDA Clears AiCE Image Reconstruction on Canon's Aquilion Precision CT
Technology | Computed Tomography (CT) | October 21, 2019
Canon Medical Systems USA Inc. has received U.S. Food and Drug Administration (FDA) 510(k) clearance on its Advanced...
FDA Clears Modules of AI-Rad Companion Chest CT From Siemens Healthineers
Technology | Computed Tomography (CT) | September 26, 2019
The U.S. Food and Drug Administration (FDA) has cleared three modules of AI-Rad Companion Chest CT, an intelligent...
Videos | Computed Tomography (CT) | August 07, 2019
This is an example of in-stent restenosis shown using spectral CT imaging.
Achenbach to Receive Inaugural 2019 Stephan Achenbach Pioneer Award in Cardiovascular CT
News | Computed Tomography (CT) | July 10, 2019
The Society of Cardiovascular Computed Tomography (SCCT) will present Stephan Achenbach, M.D., FSCCT with the inaugural...
New Type of Cardiac Care to Cut Imaging Wait Times and Unnecessary Hospital Admissions
News | Computed Tomography (CT) | June 20, 2019
A new type of care for cardiac patients at St. Paul’s Hospital, Vancouver, has the potential to reduce heart imaging...
Canon Medical Receives FDA Clearance for AiCE Reconstruction Technology for CT
Technology | Computed Tomography (CT) | June 18, 2019
Canon Medical Systems USA Inc. has received 510(k) clearance on its new deep convolutional neural network (DCNN) image...
SCCT Announces 2019 Gold Medal Award Recipients

Jonathon Leipsic, M.D., (left) and Gilbert Raff, M.D., (right)

News | Computed Tomography (CT) | June 05, 2019
The Society of Cardiovascular Computed Tomography (SCCT) will present the 2019 Gold Medal Award to Jonathon Leipsic, M....
Johns Hopkins Medicine First in U.S. to Install Canon Medical's Aquilion Precision
News | Computed Tomography (CT) | March 26, 2019
Johns Hopkins Medicine now has access to the first Ultra-High Resolution computed tomography (UHR CT) system for...
Siemens Healthineers Debuts Cardiovascular Edition of Somatom go.Top CT
News | Computed Tomography (CT) | March 14, 2019
Siemens Healthineers will introduce the Somatom go.Top Cardiovascular Edition, a new version of its established...
Canon Medical Introduces Deep Learning-Based CT Image Reconstruction
News | Computed Tomography (CT) | February 27, 2019
Canon Medical Systems recently introduced AiCE (Advanced intelligent Clear IQ Engine), a deep convolutional neural...
Overlay Init