News | November 15, 2011

Study Finds Comparable Results With Bioabsorbable, Conventional DES

November 15, 2011 — A clinical trial has shown a drug-eluting stent (DES) with a bioabsorbable polymer has comparable outcomes to a DES with a durable polymer. Results of the EVOLVE clinical trial were presented at the 23rd annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium, sponsored by the Cardiovascular Research Foundation.

 

Synergy everolimus-eluting stent system compared to the Promus Element everolimus-eluting stent

Durable polymer coatings on DES have been associated with chronic inflammation and impaired healing. Bioabsorbable polymer-coated drug-delivery systems may reduce the risk of late events, including stent thrombosis, and the need for prolonged dual antiplatelet therapy.

The EVOLVE trial is a prospective, multi-center, randomized, single blind, first-in-human non-inferiority trial. Subjects were randomized 1:1:1 to either of two formulations of the Synergy everolimus-eluting stent (full or one-half dose) with a bioabsorbable polymer and a standard DES - Promus Element everolimus-eluting stent.

The primary clinical endpoint was the 30-day rate of target lesion failure; this was defined as cardiac death related to the target vessel (TV), myocardial infarction related to the TV, or target lesion revascularization. The primary angiographic endpoint was 6-month in-stent late loss.

A total of 291 subjects were enrolled in the trial between July 29, 2010 and Jan. 20, 2011 at 29 sites in Europe, Australia, and New Zealand. The mean subject age was 63 years, 73.1 percent were male, and 19.3 percent had medically treated diabetes.

In the bioabsorbable stent group with the full dose (n= 94), late loss at six months was .10 mm and 30-day target lesion failure was 1.1 percent. In the bioabsorbable stent group with ½ dose (n=99), late loss at six months was 0.13 mm and 30-day target lesion failure was 3.1 percent.

These results compare to the use of a traditional drug-eluting stent (n=98), in which late loss at six months was .15 mm and 30-day target lesion failure was 0 percent.

“Clinical events were low and comparable with no stent thromboses in any group,” said lead investigator Ian T. Meredith, MBBS, Ph.D. Meredith is professor and director of Monash HEART and executive director of Monash Cardiovascular Research Centre at Monash Medical Centre and Monash University in Melbourne, Australia.

“These results support the safety and efficacy of the novel abluminal bioabsorbable polymer everolimus-eluting stent for the treatment of patients with de novo coronary artery disease. Additional research is needed to evaluate clinical event rates and the potential for dual antiplatelet therapy reduction with this novel stent. ” said Meredith.

The EVOLVE trial is funded by Boston Scientific Corp. Meredith is a member of the Scientific Advisory Board of Boston Scientific, but has no financial relationship with the company.

For more information: www.crf.org

Related Content

DISRUPT BTK Study Shows Positive Results With Lithoplasty in Calcified Lesions Below the Knee
News | Peripheral Artery Disease (PAD)| September 20, 2017
Shockwave Medical reported positive results from the DISRUPT BTK Study, which were presented at the annual...
Corindus Announces First Patient Enrolled in PRECISION GRX Registry
News | Robotic Systems| September 18, 2017
September 18, 2017 — Corindus Vascular Robotics Inc.
Two-Year ILLUMENATE Trial Data Demonstrate Efficacy of Stellarex Drug-Coated Balloon
News | Drug-Eluting Balloons| September 18, 2017
Philips announced the two-year results from the ILLUMENATE European randomized clinical trial (EU RCT) demonstrating...
Sentinel Cerebral Protection System Significantly Reduces Stroke and Mortality in TAVR
News | Embolic Protection Devices| September 18, 2017
September 18, 2017 – Claret Medical announced publication of a new study in the...
Marijuana Associated With Three-Fold Risk of Death From Hypertension
News | Hypertension| September 14, 2017
Marijuana use is associated with a three-fold risk of death from hypertension, according to research published recently...
Peter Schneider, M.D. presents late breaking clinical trial results at VIVA 17 in Las Vegas. Panelists (l to r) Krishna Rocha-Singh, M.D., Sean Lyden, M.D., John Kaufman, M.D., Donna Buckley, M.D.

Peter Schneider, M.D. presents late breaking clinical trial results at VIVA 17 in Las Vegas. Panelists (l to r) Krishna Rocha-Singh, M.D., Sean Lyden, M.D., John Kaufman, M.D., Donna Buckley, M.D.

Feature | Cath Lab| September 14, 2017
September 14, 2017 — Here are quick summaries for all the key late-breaking vascular and endovascular clinical trials
Medtronic Announces Japanese Regulatory Approval for In.Pact Admiral Drug-Coated Balloon
News | Drug-Eluting Balloons| September 13, 2017
Medtronic plc announced that the In.Pact Admiral Drug-Coated Balloon (DCB) received approval from the Japanese Ministry...
PQ Bypass Reports Positive Results for Detour System in Patients With Long Femoropopliteal Blockages
News | Peripheral Artery Disease (PAD)| September 13, 2017
A subset analysis of the DETOUR I clinical trial showed promising safety and effectiveness results of PQ Bypass’ Detour...
News | Cardiac Diagnostics| September 12, 2017
Contracting shingles, a reactivation of the chickenpox virus, increases a person’s risk of stroke and heart attack,...
Vascular screening for abdominal aortic aneurysm, peripheral artery disease and hypertension during the VIVA Study in Denmark

Vascular screening for abdominal aortic aneurysm, peripheral artery disease and hypertension during the VIVA Study. Photo credit: Lisbeth Hasager Justesen, Viborg Hospital.

News | Cardiac Diagnostics| September 12, 2017
September 12, 2017 — A new screening program for vascular disease saves one life for every 169 men assessed, accordin
Overlay Init