News | October 14, 2008

SYNTAX Data Show Comparable Safety for TAXUS Express2 Stents, Bypass Surgery

October 15, 2008 – At TCT 2008, Boston Scientific Corp. announced 12-month left main and three-vessel disease subset data from its landmark SYNTAX trial comparing percutaneous coronary intervention (PCI) using the TAXUS Express2 Paclitaxel-Eluting Coronary Stent System to contemporary coronary artery bypass graft (CABG) surgery.

The results reinforced previously announced data demonstrating no overall statistically significant differences between PCI and CABG in rates of death or myocardial infarction (MI). The company also presented an analysis of the data based on the SYNTAX Score, a new tool that seeks to provide guidance to physicians on optimal treatment options for this high-risk group of patients, showing similar safety and efficacy outcomes for two- thirds of SYNTAX randomized patients.

The SYNTAX trial is the first large scale randomized, controlled clinical trial comparing PCI using drug-eluting stents (DES) to CABG in patients with left main disease and three-vessel disease. These patient groups are typically treated with CABG and represent a population with far more complex anatomy and advanced disease than those studied in prior DES clinical trials.

The goal of the trial is to expand the body of knowledge of PCI use and help inform physicians and patients on appropriate treatment options for the sickest patients.

According to Boston Scientific, the SYNTAX Score is breaking new ground by scientifically defining a new measure for anatomical complexity that seeks to provide guidance to physicians on optimal treatment options for this high-risk group of patients.

The SYNTAX Score characterizes coronary anatomy based on lesion frequency, complexity and location, relying on data from the SYNTAX trial, and assigns a score to each patient. The analysis of the raw SYNTAX Score data presented demonstrated that PCI and CABG patients whose scores fell into the lower or intermediate terciles of complexity had similar rates of MACCE (Major Adverse Cardiovascular or Cerebrovascular Event rate, including all-cause death, stroke, MI and repeat revascularization) at 12 months. For patients whose SYNTAX Score fell into the upper tercile -- those with the greatest lesion complexity -- there was a significant increase in MACCE for PCI patients compared with CABG patients.

The 12-month subset results for patients with left main disease reported comparable rates of overall MACCE for the CABG group and the PCI group (13.6 percent for CABG versus 15.8 percent for PCI, p=0.44), as well as similar overall safety outcomes (death, stroke, MI) for the two groups (9.1 percent for CABG versus 7.0 percent for PCI, p=0.29). As expected, the rate of revascularization was significantly higher in the PCI group (12.0 percent for PCI versus 6.7 percent for CABG, p=0.02), while the rate of stroke was significantly higher in the CABG group (2.7 percent for CABG versus 0.3 percent for PCI, p=0.009). The subset results for patients with three-vessel disease reported comparable overall safety outcomes for the two groups (6.4 percent for CABG versus 7.9 percent for PCI, p=0.39), an expected higher rate of revascularization for PCI (14.7 percent for PCI versus 5.4 percent for CABG, p=28mm in length or requiring multiple stents.

For more information: www.bostonscientific.com

Related Content

Medtronic Announces Global Resolute Onyx DES One-Month DAPT Study
News | Antiplatelet and Anticoagulation Therapies| August 18, 2017
Medtronic plc announced a global randomized clinical trial that will evaluate one-month dual antiplatelet therapy (DAPT...
Abbott Initiates XIENCE Short DAPT Clinical Trial
News | Antiplatelet and Anticoagulation Therapies| August 03, 2017
Abbott recently announced the first patient has been enrolled in a clinical study evaluating the short-term use of...
Onyx DES 2.0 mm stent meets primary endpoints in small vessels
News | June 12, 2017
June 12, 2017 – The Medtronic Resolute Onyx Drug-Eluting Stent (DES) met its primary endpoint of target lesion failur
First Pennsylvania Patient Treated in LEADERS FREE II Trial of BioFreedom Drug-Coated Stent
News | Stents Drug Eluting| May 12, 2017
PinnacleHealth CardioVascular Institute enrolled the first patient in Pennsylvania in a trial assessing the safety and...
Resolute Onyx DES, drug eluting stent, medtronic, gains FDA approval
Technology | Stents Drug Eluting| May 01, 2017
May 1, 2017 — The U.S.
Sponsored Content | Videos | Stents Drug Eluting| May 01, 2017
This video, provided by Medtronic, demonstrates the Resolute Onyx coronary stent.
Biosensors, BioFreedom drug-coated stent, LEADERS FREE II IDE trial, first patient, U.S. pivotal study
News | Stents Drug Eluting| March 03, 2017
Biosensors International Group Ltd. announced in February enrollment of the first patient in LEADERS FREE II, its new...
CeloNova Cobra Pzf stent
Technology | Stents| March 02, 2017
March 2, 2017 — The U.S. Food and Drug Administration (FDA) cleared CeloNova BioSciences Inc.
Synergy stent, abluminal polymer DES, bioresorbable polymer DES, bioresorbable polymer metallic stent

The Synergy stent is the first FDA cleared drug-eluting stent to use a bioresorbable polymer drug carrier. When the polymer dissolves after about four months, the devices become a bare metal stent. The technology is supposed to reduce the rate of late stent thrombosis due to vessel inflammation caused by durable polymers.

Feature | Stents Bioresorbable| January 17, 2017 | Dave Fornell
One of the big advancements in drug-eluting stent (DES) technology has been the development of bioresorbable polymers
OCT, intravascular imaging, stent, good stent apposition on vessel wall, TRANSFORM-OCT study

An OCT image showing good stent strut apposition against the vessel wall.

News | Stents| January 13, 2017
January 13, 2017 — Results from TRANSFORM-OCT, a prospective, randomized trial using optical coherence tomography (OC
Overlay Init