News | August 28, 2008

Talent Thoracic Stent Graft Proves Safe Treatment for Aortic Aneurysms

August 29, 2008 - The Vascular Medtronic Talent Thoracic Stent Graft System (VALOR) is a safe and effective endovascular therapy, as an alternative to open surgery in patients with thoracic aortic aneurysms who were considered candidates for open surgical repair, according to research published in the September 2008 Journal of Vascular Surgery, published by the Society for Vascular Surgery.

Ronald M. Fairman, M.D., professor of surgery, chief of the division of vascular surgery at the Hospital of the University of Pennsylvania in Philadelphia and National Principal Investigator, reported the results of this prospective, non-randomized, multi-center, pivotal trial conducted at 38 sites. A total of 195 patients were enrolled in the VALOR Trial and 189 patients were identified as retrospective open surgical subjects. Endovascular enrollment occurred between December 2003 and June 2005 and endovascular results were compared with retrospective open surgical data from three centers of excellence.

The mean number of Talent Thoracic Stent Graft components implanted was 2.7 ± 1.3 devices per patient. Twenty-five percent of the proximal main Talent Thoracic Stent Graft components implanted had diameters smaller than 26 mm or larger than 40 mm. Left subclavian artery revascularization was performed prior to the initial stent graft procedure in 5.2 percent of patients, and iliac conduits were utilized in 21.1 percent of patients. Thirty-three percent of patients had the bare spring segment of the most proximally implanted device in zones 1 or 2 of the aortic arch. One hundred and ninety-four patients (99.5 percent) had successful vessel access and deployment of the Talent at the intended site.

The 30 day VALOR results included perioperative mortality (2.1 percent), major adverse advents (41 percent), incidence of paraplegia (1.5 percent), paraparesis (7.2 percent), and stroke (3.6 percent). The 12 month VALOR results included all-cause mortality (16.1 percent), aneurysm-related mortality (3.1 percent), conversion to open surgery (0.5 percent), target aneurysm rupture (0.5 percent), stent graft migration > 10 mm (3.9 percent), endoleak (12.2 percent), stent graft patency (100 percent), stable or decreasing aneurysm diameter (91.5 percent) and loss of stent graft integrity (four patients). There were no instances of deployment-related events or perforation of the aorta by a graft component.

“The Talent Thoracic Stent Graft showed statistically superior performance with respect to acute procedural outcomes, 30-day major adverse events (41 percent vs. 84.4 percent, p

The submission of these pivotal trial results lead to FDA approval of the Talent Thoracic Stent Graft System for treatment of thoracic aortic aneurysms in June, 2008.

For more information: www.jvascsurg.org, www.VascularWeb.org

Related Content

Medtronic Announces Global Resolute Onyx DES One-Month DAPT Study
News | Antiplatelet and Anticoagulation Therapies| August 18, 2017
Medtronic plc announced a global randomized clinical trial that will evaluate one-month dual antiplatelet therapy (DAPT...
Bivalirudin exhibited an improvement in 30-day all-cause mortality when injected post PCI.
News | Antiplatelet and Anticoagulation Therapies| August 16, 2017
August 16, 2017 — A study has examined the efficacies of various post-percutaneous coronary intervention (PCI) bivali
ESC 2017 late breaking trial hot line study presentations.
News | Clinical Study| August 16, 2017
Aug. 16, 2017 – The European Society of Cardiology (ESC) Congress 2017 includes several Hot Line Late-breaking Clinic
News | Drug-Eluting Balloons| August 15, 2017
Surmodics Inc. announced receipt of an investigational device exemption (IDE) from the U.S. Food and Drug...
The Vascular Dynamics MobiusHD device enhances the carotid baroreceptors to reduce resistant hypertension.
News | Hypertension| August 15, 2017
Aug. 15, 2017 — The U.S. Food and Drug Administration (FDA) has approved the Vascular Dynamics Inc.
Abbott Initiates First Clinical Trial of Clip-Based Tricuspid Repair System
News | Heart Valve Technology| August 09, 2017
Abbott announced that the first patient has been enrolled in a clinical study to evaluate a minimally invasive clip-...
Three New Atrial Fibrillation Studies to Feature HeartLight Endoscopic Ablation System
News | Ablation Systems| August 07, 2017
CardioFocus Inc. announced that its HeartLight Endoscopic Ablation System is being featured in three new major clinical...
Registry Identifies Early Onset of Heart Failure and Lack of Defibrillators in Asia
News | Heart Failure| August 03, 2017
August 3, 2017 — The Asian Pacific Society of Cardiology (ASPC) held its first-ever late-breaking...