News | April 01, 2008

TAXUS Outcomes Similar in Diabetic Patients Compared to Non-Diabetics

April 1, 2008 - Despite the known increased rates of mortality and restenosis for diabetics versus non-diabetics in patients with cardiovascular disease, the TAXUS Stent had comparable levels of late loss and target lesion revascularization (TLR) across these patient populations, according to results from TAXUS IV and TAXUS V randomized clinical trials.

The analysis compared the safety and efficacy of the TAXUS Express Paclitaxel-Eluting Coronary Stent System in diabetic versus non-diabetic patients.

The study also showed no significant differences in target vessel revascularization (TVR), stent thrombosis or myocardial infarction (MI), after adjustments were made for differences in other baseline characteristics between patients with or without diabetes. Analysis of the data was presented by Gregg W. Stone, M.D., of the Columbia University Medical Center in New York, at the SCAI Annual Scientific Sessions in Partnership with the ACC/i2 Summit in Chicago.

"The TAXUS IV/V diabetic subset data indicated that the TAXUS Stent mitigated the impact of diabetes as a risk factor for restenosis following stenting procedures in the patients studied," said Dr. Stone. "Diabetic patients treated with TAXUS Stents compared to bare-metal stents had significantly improved event-free survival, particularly important in high-risk patients with diabetes."

The pooled analysis included angiographic outcomes at nine months and clinical outcomes at three years among 338 diabetic patients and 901 non-diabetic patients treated with the TAXUS Stent from the TAXUS IV and V clinical trials. Nine-month angiographic outcomes showed equivalent in-segment late loss (0.27mm vs. 0.31mm, p=0.28) and binary restenosis (14.3 percent vs. 15.1 percent, p=0.83) in diabetics and non-diabetics, respectively.

At three years, TLR was similar for diabetic and non-diabetic patients (12.4 percent vs. 10.1 percent, p=0.25), despite significant baseline differences and increased comorbidity risk in diabetic patients. TVR was higher in diabetics (21.4 percent vs. 15.7 percent, p=0.017), due to an increase in remote TVR events (outside the stented segment), which is an indicator of the more aggressive background disease progression in diabetics. Three-year rates of stent thrombosis under Protocol definition (0.9 percent vs. 1.3 percent, p=0.63) and ARC Definite/Probable (1.6 percent vs. 1.9 percent, p=0.73) were similar, even without multivariate adjustment.

The TAXUS IV/V analysis also compared 338 diabetic patients treated with the TAXUS Stent versus 336 diabetic patients treated with bare-metal stents (BMS). Three-year rates of TVR and TLR were reduced by roughly 50 percent in diabetic patients treated with the TAXUS Stent compared to BMS, consistent with results seen in other high-risk patient groups. The TAXUS Stent showed comparable safety to BMS in diabetics, with no significant differences in death (7.3 percent vs. 7.1 percent, p=0.91), cardiac death (4.6 percent vs. 2.7 percent, p=0.23), MI (6.5 percent vs. 6.6 percent, p=0.83) or ARC Definite/Probable stent thrombosis (1.6 percent vs. 1.5 percent, p=1.00) in TAXUS and BMS, respectively.

The safety and effectiveness of the TAXUS Express Stent has not been established in patients with diabetes in the United States.

For more information: www.bostonscientific.com

Related Content

Abbott Initiates XIENCE Short DAPT Clinical Trial
News | Antiplatelet and Anticoagulation Therapies| August 03, 2017
Abbott recently announced the first patient has been enrolled in a clinical study evaluating the short-term use of...
Onyx DES 2.0 mm stent meets primary endpoints in small vessels
News | June 12, 2017
June 12, 2017 – The Medtronic Resolute Onyx Drug-Eluting Stent (DES) met its primary endpoint of target lesion failur
First Pennsylvania Patient Treated in LEADERS FREE II Trial of BioFreedom Drug-Coated Stent
News | Stents Drug Eluting| May 12, 2017
PinnacleHealth CardioVascular Institute enrolled the first patient in Pennsylvania in a trial assessing the safety and...
Resolute Onyx DES, drug eluting stent, medtronic, gains FDA approval
Technology | Stents Drug Eluting| May 01, 2017
May 1, 2017 — The U.S.
Sponsored Content | Videos | Stents Drug Eluting| May 01, 2017
This video, provided by Medtronic, demonstrates the Resolute Onyx coronary stent.
Biosensors, BioFreedom drug-coated stent, LEADERS FREE II IDE trial, first patient, U.S. pivotal study
News | Stents Drug Eluting| March 03, 2017
Biosensors International Group Ltd. announced in February enrollment of the first patient in LEADERS FREE II, its new...
CeloNova Cobra Pzf stent
Technology | Stents| March 02, 2017
March 2, 2017 — The U.S. Food and Drug Administration (FDA) cleared CeloNova BioSciences Inc.
Synergy stent, abluminal polymer DES, bioresorbable polymer DES, bioresorbable polymer metallic stent

The Synergy stent is the first FDA cleared drug-eluting stent to use a bioresorbable polymer drug carrier. When the polymer dissolves after about four months, the devices become a bare metal stent. The technology is supposed to reduce the rate of late stent thrombosis due to vessel inflammation caused by durable polymers.

Feature | Stents Bioresorbable| January 17, 2017 | Dave Fornell
One of the big advancements in drug-eluting stent (DES) technology has been the development of bioresorbable polymers
OCT, intravascular imaging, stent, good stent apposition on vessel wall, TRANSFORM-OCT study

An OCT image showing good stent strut apposition against the vessel wall.

News | Stents| January 13, 2017
January 13, 2017 — Results from TRANSFORM-OCT, a prospective, randomized trial using optical coherence tomography (OC
EXCEL Trial, TCT 2016, drug-eluting stents, CABG, surgery left main heart disease, LMCAD

Gregg W. Stone, M.D., presenting the EXCEL data at TCT 2016 during a standing room only late-breaking trial session.

Feature | Stents| January 12, 2017 | Dave Fornell
The biggest news from the 2016 Transcatheter Cardiovascular Therapeutics (TCT) meeting this past fall was the results
Overlay Init