News | Stents Drug Eluting | October 11, 2019

Supraflex Drug-Eluting Stent Superior to Xience in Two-Year Target Vessel Failure

Findings of TALENT trial two-year results reinforce SMT’s Supraflex stent clinically at par with Abbott’s Xience family

Supraflex Drug-Eluting Stent Superior to Xience in Two-Year Target Vessel Failure

October 11, 2019 — The ultra-thin Supraflex drug-eluting stent (DES) from SMT maintained numerically lower outcomes at two years of follow-up in a randomized trial against Abbott’s Xience stent, according to results presented at Transcatheter Cardiovascular Therapeutics (TCT) 2019, Sept. 25-29 in San Francisco. 

Patients who got the Supraflex stent in the TALENT trial had 6.9 percent target lesion failure occur at 720 days (versus 7.9% percent of Xience recipients), according to a presentation by Azfar Zaman, M.D., cardiac catheter laboratories, Royal Freeman Hospital, Newcastle, United Kingdom.

Patrick Serruys, M.D., was the chair for the TALENT trial. The study was conducted in seven countries — the U.K., Netherlands, Poland, Spain, Italy, Hungary and Bulgaria — across 23 centers with a sample size of 1,435 patients. Xience is regarded as the global standard in safety and efficacy for drug-eluting stents. 

Presenting the findings of the TALENT trial, Zaman said, “Safety and efficacy of Supraflex SES with ultra-thin struts and biodegradable polymer were compared with Xience EES in [an] all comers-population. Supraflex was found to be non-inferior to the Xience for DOCE (device-oriented end points) at 24 months in an all comer-population.” 

Upendra Kaul, M.D., one of the leading cardiologists from India, was the co-chair of the TALENT Study. Commenting on the study, Kaul said, "There remained a perception that stents produced outside of India were superior to homegrown devices. 

There were demands from Indian manufacturers to prove that their devices are comparable to those made elsewhere in robust clinical trials.” 

The individual components of the primary endpoint suggest the difference was mainly driven by myocardial infarction (MI):

  • Target vessel MI: 3 percent versus 3.8 percent (P=0.382);

  • Cardiac death: 1.3 percent versus 1.6 percent (P=0.659); and

  • Clinically driven target lesion revascularization: 4.9 percent versus 5.3 percent (P=0.718).

Over the entire two-year study period, stent thrombosis rates were similar between Supraflex and Xience groups. However, late and very late instances were more likely with Xience (0.5 percent versus 1 percent).

Prof. R. de Winter, M.D., Academisch Medisch Centrum, Amsterdam, The Netherlands; and Zaman were the principal investigators for the TALENT trial.  

Supraflex is available in 75 countries across the world and has advanced features like a biodegradable polymer and ultrathin strut (60μm) thickness compared tothe  81 μm strut thickness and biostable polymer coating of Xience. The TALENT clinical study result matches with the published meta-analysis, highlighting the benefits of lower strut thickness. 

For more information: www.smtpl.com


Related Content

News | Cardiovascular Clinical Studies

April 24, 2024 —Hello Heart, a digital leader in preventive heart health, today announced results from its latest study ...

Home April 24, 2024
Home
News | Cardiovascular Clinical Studies

April 22, 2024 — Corvia Medical, Inc, a company dedicated to transforming the treatment of heart failure, welcomes the ...

Home April 22, 2024
Home
News | Cardiovascular Clinical Studies

April 16, 2024 — CVRx, Inc., a commercial-stage medical device company, announced today the availability of additional ...

Home April 16, 2024
Home
News | Cardiovascular Clinical Studies

April 11, 2024 — Transcatheter aortic valve replacement (TAVR) was found to bring no increased risks and was associated ...

Home April 11, 2024
Home
News | Cardiovascular Clinical Studies

April 11, 2024 — People with a buildup of fatty atherosclerotic plaque in the heart’s arteries considered at risk of ...

Home April 11, 2024
Home
News | Cardiovascular Clinical Studies

April 9, 2024 — Patients who took an angiotensin-converting enzyme (ACE) inhibitor while undergoing cancer treatment ...

Home April 09, 2024
Home
News | Cardiovascular Clinical Studies

April 9, 2024 — One of the first studies to attempt to treat early-stage heart failure in patients with Type 2 diabetes ...

Home April 09, 2024
Home
News | Cardiovascular Clinical Studies

April 9, 2024 — The investigational drug ninerafaxstat showed a good tolerability and safety profile, along with ...

Home April 09, 2024
Home
News | Cardiovascular Clinical Studies

April 9, 2024 — Administering tranexamic acid (TxA), a drug used to reduce bleeding during heart surgery, topically ...

Home April 09, 2024
Home
News | Cardiovascular Clinical Studies

April 9, 2024 — Using a web application to qualify individuals for treatment with a nonprescription statin closely ...

Home April 09, 2024
Home
Subscribe Now