Technology | Computed Tomography (CT) | December 14, 2017

Siemens Healthineers Strengthens CT Portfolio With Four New Systems at RSNA 2017

New Somatom go. scanners provide mobile workflow for advanced clinical fields; new high-end Somatom Edge Plus and Somatom Force feature FAST 3-D Camera for more precise, consistent patient positioning

Siemens Healthineers Strengthens CT Portfolio With Four New Systems at RSNA 2017

The Somatom Force with the new FAST 3D Camera

December 14, 2017 — Siemens Healthineers introduced four new computed tomography (CT) scanners across two platforms at the 2017 Radiological Society of North America (RSNA) Annual Meeting, Nov. 26-Dec. 1 in Chicago. The two new scanners in the Somatom go. Platform — Somatom go.All and Somatom go.Top — expand the mobile workflow into advanced fields such as cardiology and CT-guided intervention. With its new high-end systems for single- and dual-source imaging — Somatom Edge Plus and Somatom Force — Siemens Healthineers is introducing the new FAST (Fully Assisting Scanner Technologies) Integrated Workflow with the new FAST 3-D Camera.

With its new models Somatom go.All and Somatom go.Top, Siemens Healthineers expands the range of clinical applications for its patient-centric mobile workflow operated via tablet and remote. With a 0.33-second rotation time and the established Stellar detector technology, the 64-slice Somatom go.All can cover scan ranges of up to 100 mm in one second. The 128-slice Somatom go.Top can perform whole-body scans of up to 200 cm with a scan speed of up to 175 mm per second. This means that users can deploy the Somatom go. platform’s mobile workflow in advanced clinical fields such as emergency medicine, interventional radiology (steered by Guide&GO, the first tablet-based solution for CT-guided interventions) and even cardiology, which is a major growth area for many healthcare providers because of the sharp rise in coronary CT angiography.

The new X-ray tube allows users to adjust the tube voltage in 10-kilovolt increments while keeping the tube current high. In this way, users can adapt the settings to each patient’s individual anatomy. Examinations performed at just 70 kv with a current of up to 825 milliamps, for instance, can significantly reduce X-ray dose and the amount of contrast. Somatom go.Top also offers TwinBeam Dual Energy imaging, which enables users to examine the same body region at two different energy levels simultaneously. The technology splits the X-ray beam into two energy spectra before it reaches the patient. With a scan mode that is no different from a routine CT examination, TwinBeam Dual Energy can therefore acquire two image datasets that provide additional information about the tissue, which is particularly beneficial in soft tissue differentiation and for oncology.

In all applications, patients benefit from a comfortable examination situation: All scanners in the Somatom go. platform (including the two new additions) are operated via a tablet and remote that can be used to control all routine and advanced examinations. Technologists can remain close to patients during the entire scan preparation process, which can make the experience more pleasant for patients, particularly children.

Additional innovative hardware designs have been introduced with the Somatom go. platform. Following integration of all computer hardware into the gantry, a new injector arm is now available. This smart, ergonomic solution allows the user to swivel the tablet and the injector around the gantry.

In the high-end segment, Siemens Healthineers introduces two new flagship products in its portfolio: Somatom Edge Plus, the new premium single-source system, and Somatom Force, the new version of the dual-source system. The new systems allow clinical users to cover all CT applications, regardless of patient or clinical issue. Both systems also offer high-precision diagnostics, which is a prerequisite for individualized prevention and therapy.

Such precise diagnostics come from the FAST applications that are integrated into the premium systems. One application is the FAST Integrated Workflow with the all-new FAST 3D Camera for automatic patient positioning. In many CT examinations, incorrect patient positioning is an obstacle to achieving optimal results. This new innovation is designed to help users eliminate position misalignment, which studies show can average around 2.6 cm from true isocenter. This misalignment positioning results in more image noise or – to counteract the noise – increased dose levels.

In Somatom Edge Plus and the Dual Source scanners Somatom Drive and Somatom Force, a 3-D camera is fitted above the patient table that uses artificial intelligence and deep learning technologies to recognize patient anatomical landmarks. This technology enables institutions to potentially have fewer rescans, decrease the time required for patients and staff, and therefore benefit from precise diagnostics at lower cost. The two touch-operated control panels fitted directly on the scanner allow radiology staff to remain close to the patient during most of the time needed for scan preparation.

The new single-source Somatom Edge Plus system combines the Straton MX Sigma X-ray tube, high power reserves at every kV value in 10-kV steps and the Stellar Infinity detector. This provides the powerful imaging chain for scanning obese patients with diagnostic confidence – enabling sharp, rich-in-contrast images at high speed and low dose. In addition, the scanner is equipped with TwinBeam Dual Energy scan modes and the Tin Filter technology that facilitates CT scans at very low doses by shielding patients from clinically irrelevant radiation. Tin Filter technology can be used in all routine examinations and allows users to perform CT imaging at very low dose values which, in the case of lung cancer screening, for instance, do not exceed those of a normal X-ray examination. With the introduction of the new scanners, Tin Filter technology is now available across the complete Siemens Healthineers CT portfolio.

The new version of the Somatom Force system delivers high-quality images, particularly in highly challenging situations. One example is functional imaging. Although functional imaging provides additional image information, the high levels of radiation involved mean that it has yet to become routine in many applications. Somatom Force allows functional imaging to become part of clinical practice because it offers a perfusion range of up to 22 cm that can cover entire organs. Its Vectron X-ray tubes, with a power-independent focal spot size of just 0.4 × 0.5 mm (IEC) and the highly sensitive Stellar Infinity detector, make Somatom Force the ideal scanner when high-speed (up to 737 mm/s), large-volume coverage combined with high image quality is required. Furthermore, the scanner offers precise and dose-neutral quantification with spectral separation in Dual Energy acquisition to generate high-quality diagnostic results.

Somatom Force and Somatom Drive also feature Rapid Results Technology that allows the dual-source scanner to communicate directly with syngo.via for zero-click postprocessing. As a result, large Dual Energy CT datasets are sent automatically to the picture archiving and communications system (PACS). This task is now part of standard reconstructions, enabling standardized and consistent image quality independent of operator skills.

Customers with existing Somatom Force and Somatom Drive CT systems will have the option of retrofitting their systems with the new FAST 3D Camera.

For more information: www.usa.healthcare.siemens.com

Related Content

A comparison of CT image of heavily calcified coronary arteries that appear to present a significant hemodynamic blockages and the correspending FFR-CT showing the patient had adequate blood flow and does not need a diagnostic angiogram or intervention.

A comparison of a CT image of heavily calcified coronary arteries that appear to present a significant hemodynamic blockage and the corresponding FFR-CT showing the patient had adequate blood flow and does not need a diagnostic angiogram or intervention. Image courtesy of Kavitha Chinnaiyan, William Beaumont Hospital.

Feature | CT Angiography (CTA) | July 23, 2018 | Dave Fornell, Editor
The use of non-invasive fractional flow reserve CT (FFR-CT) was the hottest topic discussed at the Society of Cardiov
Videos | CT Angiography (CTA) | July 19, 2018
Kavitha Chinnaiyan, M.D., FACC, FSCCT, associate professor, Oakland University, William Beaumont School of Medicine,
Videos | CT Angiography (CTA) | July 18, 2018
A discussion with Gianluca Pontone, M.D., Ph.D., FSCCT, director of cardiovascular MRI, Centro Cardiologico Manzino,
Videos | CT Angiography (CTA) | July 17, 2018
A discussion with Todd Villines, M.D., FACC, FAHA, FSCCT, cardiologist, Georgetown Medical Center, and president of t
HeartFlow Announces New Commercial Coverage With UnitedHealthcare
News | CT Angiography (CTA) | July 03, 2018
HeartFlow Inc. announced that UnitedHealthcare now covers the HeartFlow FFRct Analysis, extending access to their 45...
Post-Mortem CT Angiography Illuminates Causes of Death
News | CT Angiography (CTA) | June 25, 2018
Computed tomography (CT) angiography is a useful adjunct to autopsy that is likely to increase the quality of post-...
iSchemaView Receives FDA Clearance for Rapid CTA
Technology | CT Angiography (CTA) | May 01, 2018
Cerebrovascular imaging analysis company iSchemaView received final clearance from the U.S. Food and Drug...
The use of metal artifact reduction software on this CCTA (CTA) cardiac CT from an Canon, Toshiba, Aquilion Precision, allows clear visualization inside a coronary stent. The 0.25 mm high-resolution reconstruction also helps delineate the various components of plaque.

The use of metal artifact reduction software on this Aquilion Precision image allows clear visualization inside a coronary stent. The 0.25 mm high-resolution reconstruction also helps delineate the various components of plaque.

Feature | CT Angiography (CTA) | April 26, 2018 | Dave Fornell
There have been a few big, recent advancements in cardiac computed tomography angiography (CCTA) imaging technology.
Siemens Healthineers, Florida Hospital Collaborate to Improve Healthcare Outcomes
News | CT Angiography (CTA) | January 23, 2018
January 23, 2018 – Siemens Healthineers and Florida Hospital, part of Adventist Health System, have announced a multi
Videos | CT Angiography (CTA) | July 21, 2017
DAIC and ITN Editor Dave Fornell discusses some of the most innovative new computed tomography (CT) technology and tr
Overlay Init