News | October 22, 2013

First Siemens ECAT Scintron Installed in Texas to Speed Cardiac Perfusion Exams

October 22, 2013 – Nuclear Imaging Services LLC (NIS) has completed the first U.S.-based ECAT Scintron installation into an outpatient cardiology facility. Gulf Coast Cardiology Group in Port Arthur, Texas, is the first to upgrade its Siemens ECAT system to Medical Imaging Electronics' (MiE) ECAT Scintron.

The scan times for the rest and stress cardiac positron emission tomography (PET) imaging protocol reduced from approximately 45 minutes to just more than 20 minutes per patient. The transfer and processing times were eliminated, thereby creating more productivity within the department while maximizing the comfort of the patient. Reducing the amount of time the patient remained under the camera not only improved efficiency but also image quality.

Gulf Coast Cardiology Group PET technologist Deena Varnado says, "The efficiency of the Scintron is great for our patients. It allows them to be scheduled on a timelier basis since we can now increase our daily patient volume. Our patients can also better tolerate the time they have to lay flat on the table due to the time being cut down to perform the scan."

The ECAT Scintron is the only upgrade path to the Siemens ECAT 47, ECAT HR+ and ECAT Accel PET systems. This upgrade eliminates the need for the ACSII along with the SUN workstation. Both units are replaced with new PC technology that will provide for faster scan times, improved reliability and longevity in the ECAT family of dedicated PET systems. Hardware and software configurations include whole body, gating and list-mode data acquisition.

T. Kuehl, MiE president and CEO, says, "The Scintron upgrade provides enhanced patient care, modern technologies and economic efficiency. This includes 3-D myocardial reconstruction with special scatter correction as well as the realignment of stress-rest miss-registration and list-mode protocols for simultaneous dynamic and gated studies to perform CFR analysis."

Expanding on its 2-D and 3-D imaging platform, the ECAT Scintron continues to develop its capabilities. NIS and MiE demonstrated its new acquisition protocols at the American Society of Nuclear Cardiology (ASNC) annual meeting in Chicago, Sept. 26-28.

MiE, based in Germany, is a manufacturer and remanufacturer of gamma camera and PET systems. The Scintron unit is always a part of a MiE system and can also be upgraded to any existing system. It takes on all processes of the scanner — data acquiring, processing and viewing, as well as gantry controlling, calibrating and servicing. 

For more information:

Related Content

Novel PET Tracer Detects Small Blood Clots

PET images (MIP 0-60 min) of three Cynomolgus monkeys. Strong signals are detected at the sites where inserted catheters had roughened surfaces. Almost no other background signal is visible. Only accumulation in the gallbladder becomes visible at the bottom of the image. Credit: Piramal Imaging GmbH, Berlin Germany.

News | PET Imaging | July 07, 2017
Blood clots in veins and arteries can lead to heart attack, stroke and pulmonary embolism, which are major causes of...
PET imaging, atherosclerotic plaque, inflammation, Ga-68-pentixafor, Technishe Universitat Munchen, Germany

Note the high uptake of Ga-68-pentixafor on multi-planar reconstructions in the organs expressing CXCR4 such as the spleen (red arrows) and adrenal glands (yellow arrows), which was nearly completely blocked by the pre-injection of AMD 3100, a potent CXCR4 inhibitor. Strong accumulation of Ga-68-pentixafor was also found in the kidneys (asterisks) reflecting the renal clearance of the tracer. In addition, high, focal activities were detected in the abdominal aorta (red arrowheads) and right carotid artery (orange arrowheads) of atherosclerotic rabbits, whereas no significant signal could be detected in the non-injured left carotid artery (white arrowheads) of atherosclerotic and control rabbits, as well as in the abdominal aorta and right carotid artery of control rabbits. Furthermore, focal activities detected with PET in atherosclerotic plaques of the abdominal aorta and the right carotid artery decreased significantly when the same rabbit was re-imaged after blocking CXCR4 receptors. Image courtesy of Fabien Hyafil, M.D., Ph.D., Department of Nuclear Medicine, Klinikum Rechts der Isar, Technische Universität München, Munich, Germany

News | PET Imaging | March 03, 2017
In the featured article of the March 2017 issue of The Journal of Nuclear Medicine, researchers demonstrate that a new...
ASNC, SNMMI, position statement, myocardial perfusion PET, coronary artery disease
News | PET Imaging | September 01, 2016
September 1, 2016 — The American Society for Nuclear Cardiology (ASNC) and the Society of...
cardiac PET, myocardial perfusion, PET-CT, cardiac perfusion

A PET-CT cardiac perfusion exam from a Siemens Biograph scanner. The black and white areas of the image show the CT imaging of the anatomy. The colored portion shows the PET overlay on the myocardium and is color-coded to show tracer uptake values. This can show areas of the heart muscle where there are perfusion defects cause by infarcts or coronary artery blockages due to a heart attack and help determine the severity of the ischemia.

Feature | PET Imaging | June 03, 2016 | Dave Fornell
Positron emission tomography (PET) is a nuclear imaging technology (also referred to as molecular imaging) that enabl
blood clot detection, single scan, rats, radionuclides, Peter Caravan, whole body

The whole body of a rat can be imaged for blood clots with one PET scan (which is overlaid here on an MRI image) using the FBP8 probe. Arrow points to a blood clot. Image courtesy of Peter Caravan, Ph.D.

News | PET Imaging | September 23, 2015
September 23, 2015 — New research de
Overlay Init