News | January 30, 2007

Implantable Sensor Beneficial for AAA Stent Repair

Jan. 31, 2007 — Researchers said this week that they have found an implantable wireless sensor that monitors blood pressure in an aneurysm sac to be safe and useful in guiding endovascular repair of an abdominal aortic aneurysm (AAA). Their prospective, non-randomized study, published in the February issue of the Journal of Vascular Surgery, used acute wireless pressure measurements to confirm aneurysm sac exclusion and to determine if intraoperative pressure measurements obtained with the sensor correlated with angiography findings during and at the completion of stent graft placement.

The accuracy of the sensor measurement was confirmed by comparing measurements obtained with an angiographic catheter. In addition, the sensor data and the angiographic findings were in agreement as to the presence of serious endoleaks in 92 percent of the 76 patients from 12 clinical centers who were studied. Thirty-day follow-up revealed no device-related safety issues.

“This trial demonstrates that this wireless sensor for aneurysm sac measurement is safe and feasible, and can be used to diagnose the location and type of endoleak during endovascular aneurysm repair,” said Takao Ohki, professor and chief in the vascular surgery department of Jikei University School of Medicine, Toyko, and professor of surgery at Albert Einstein College of Medicine, North Shore/LIJ Hospital in Long Island, N.Y.

“The benefit of endovascular repair of an AAA includes the fact that the treatment can be performed through a small incision in the groin area, rather than the large abdominal incision used in open surgical repair,” Dr. Ohki said. “However, one downside to the endovascular approach is the occurrence of an endoleak, where blood still flows into the aneurysm, not eliminating the risk of aneurysm rupture and death.”

Dr. Ohki added that the APEX data was submitted to the FDA, which allowed this technology to become commercially available for stent graft implantation procedures. Future studies will focus on using sac pressure monitoring as an alternative to computed tomography for long-term aneurysm surveillance.

Related Content

First U.S. Patient Receives Gore Tag Conformable Thoracic Stent Graft With Active Control
News | Stent Grafts | July 10, 2019
W. L. Gore & Associates Inc. (Gore) announced the first U.S. implant of the Gore Tag Conformable Thoracic Stent...
Gore Receives FDA Approval for Gore Tag Conformable Thoracic Stent Graft
Technology | Stent Grafts | May 15, 2019
W. L. Gore & Associates Inc. (Gore) announced the U.S. Food and Drug Administration (FDA) has granted regulatory...
Aortic Stent Graft Global Market to Reach $5.4 Billion by 2028
News | Stent Grafts | February 14, 2019
Abdominal aortic stent grafts will remain the largest segment in the global aortic stent graft market at least through...
Medtronic Receives FDA Approval for Valiant Navion Thoracic Stent Graft System
Technology | Stent Grafts | February 07, 2019
Medtronic plc recently received U.S. Food and Drug Administration (FDA) approval for the Valiant Navion thoracic stent...
Endologix Ends Unrestricted Sales and Use of Nellix System
News | Stent Grafts | January 07, 2019
January 7, 2019 — Endologix Inc.
Endologix Reports Positive One-Year Results From the Ovation LUCY Study
News | Stent Grafts | July 16, 2018
Endologix Inc. announced one-year results from the LUCY (Evaluation of FemaLes who are Underrepresented Candidates for...
FDA Committee Votes in Favor of Incraft AAA Stent Graft System
News | Stent Grafts | June 13, 2018
Cardinal Health announced that its Incraft Abdominal Aortic Aneurysm (AAA) Stent Graft System has received a favorable...
First Patient Enrolled in Gore Excluder Investigational Study
News | Stent Grafts | January 08, 2018
January 8, 2018 — W. L. Gore & Associates Inc.
FDA Concerned About Increase in stent graft Endovascular Type III Leaks
News | Stent Grafts | October 09, 2017
October 9, 2017 — The U.S.
Gore Announces First-in-Human Use of Gore TAG Conformable Thoracic Stent Graft
News | Stent Grafts | July 17, 2017
W. L. Gore & Associates Inc. announced the first patient implant of the Gore TAG Conformable Thoracic Stent Graft...